E90 Midsemester Report

E90 Midsemester Report. Aron P. Dobos 20 March 2006. stimulus. TDR. reflection. ampl. dist. Time Domain Reflectometer. Measurement device for cable characterization and testing

rthomason
Download Presentation

E90 Midsemester Report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. E90MidsemesterReport Aron P. Dobos 20 March 2006

  2. stimulus TDR reflection ampl. dist. Time Domain Reflectometer • Measurement device for cable characterization and testing • Instrument sends a pulse of energy down the test cable and measures the reflections from any discontinuities in the cable • Results are reported as an amplitude vs. time (or distance) waveform

  3. PC Host Interface (Parallel Port) ADuC7026 (ADC, DAC, SPI, GPIO) TDR (Timebase, Step gen., Sampler) test cable Implementation • Implementation based around the Analog Devices ADuC7026 microcontroller • TDR acquisition circuit with step generator, timebase circuit, sampler • Interfaces to host PC through the parallel port

  4. Hardware -Circuit built with Surface Mount Technology (SMT) components to minimize parasitic effects -4 layer PCB used to facilitate proper high frequency grounding and supply routing -Two copies of the TDR circuit have been built -TDR circuit plugs into the standard ADuC7026 development board for simplicity

  5. Testing • High speed equivalent-time sampling oscilloscope (20 GHz+ bandwidth) required for accurately measuring rise/fall times of the pulse generator and sampling circuit • Special hardware pretrigger output implemented to trigger the Tektronix 11801 scope • Realtime 100 or 500 MHz scope used for testing and calibrating the timebase

  6. Software • PC host control software written using CVI provides access to the debugging functions but does not yet provide a useful interface for making TDR measurements • Microcontroller (ADuC7026) software has been written with extensive debugging facilities but just basic waveform acquisition capabilities • Xilinx FPGA-based timebase circuit VHDL code works but must be expanded to control additional hardware resources

  7. Tasks • -Rewrite embedded timebase controller software and PC host interface for usability • Clean up waveform aberrations if possible by tweaking the sampler circuit • Decrease minimum data point spacing from 25 ps to 12.5 ps or perhaps even more

  8. Questions