210 likes | 408 Views
David Rodríguez Piñeiro GSI Darmstadt PANDA Collaboration Meeting Turin 15. 06. 2009. EMC BW Endcap. Backward Endcap EMC. 1.– Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary. Backward Endcap EMC.
E N D
David Rodríguez PiñeiroGSI DarmstadtPANDA Collaboration MeetingTurin15. 06. 2009 EMC BW Endcap
Backward Endcap EMC 1.– Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Extension of BW Endcap in Z Direction 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary It extends further backwards as compared to official drawings David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Support Structure (I) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary DIN 1025-IPB360-1.0112 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Support Structure (II) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary - Rails for placing - Order installation/ desensitization - Cylindrical space upstream - Interaction with beam pipe Rail David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Support Structure (III) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Too Tight Placing the pump further David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Support Structure (IV.a) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Stress Analysis 1 Ton Max Stress: 26,14 MPa Steel: Safety factor = 10 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Support Structure (IV.b) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Deformation Analysis Vertical displacement 0,8 mm David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (I) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (II) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Held by 4 rollers in the common rail Available area = = 4x1350 = = 5400 mm2 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (III.a) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Stress Analysis 3 mm Polyethylene Max Stress: 4,29 MPa Polyethylene: Safety factor > 5 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (III.b) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Deformation Analysis 3 mm Polyethylene Max deformation < 1 mm David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (IV.a) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Stress Analysis 1 mm Aluminium Max Stress: 66,04 MPa Aluminium: Safety factor > 4 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Tracking Supplies (IV.b) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Ansys Stress Analysis 1 mm Aluminium Max deformation < 0,5 mm David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC ToF Supplies (I) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Space Reserved for ToF Supplies Gross Area > 16000 mm2 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC ToF Supplies (II) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Integrate ToF supplies Support into DIRC and Tracking Support David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC ToF & Tracking Supplies 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Posibility to switch the spaces for Tracking and ToF, depending on the needed area. David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC MVD Supplies (I) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary New proposal: Rectangular Shape David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC MVD Supplies (II) 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary • Better use of the space • Easier and safer insulation system • 24 crystals gain! • MVD Demand: 44000mm2 With this proposal: Free Area around Beam Pipe for MVD Supplies ~ 50000 mm2 David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Summary 1. – Extension of BW Endcap in Z Direction 2.– Support Structure 3.– Tracking Supplies 4. – ToF Supplies 5. – MVD Supplies 6. – Summary Extension of BW in Z Direction: at least 1000 mm Supporting Structure:Advanced Space for Tracking Supplies:Feasible Space for ToF Supplies:To Be Determined Space for MVD Supplies:Rectangular Solution David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting
Backward Endcap EMC Thank you! Personal Contact: d.rodriguezpineiro@gsi.de Tel: +49 (0) 615971/1634 www-panda.gsi.de David Rodríguez Piñeiro - GSI Darmstadt - Turin Collaboration Meeting