1 / 99

PT2060 Monitor

PT2060 Monitor. Nov., 2010. P r o v i b T e c h. Content. PT2060 Overview PT2060 Features PT2060 Modules PT2060 Configuration How to Order PT2060 PT2060 Modbus PT2060 Modules FAQ for sales PT2060 Solution Example. Complete Offering. Features. DTM- Digital Transmitter Monitors.

sage-morris
Download Presentation

PT2060 Monitor

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PT2060 Monitor Nov., 2010 P r o v i b T e c h

  2. Content • PT2060 Overview • PT2060 Features • PT2060 Modules • PT2060 Configuration • How to Order PT2060 • PT2060 Modbus • PT2060 Modules FAQ for sales • PT2060 Solution Example

  3. Complete Offering Features DTM- Digital Transmitter Monitors API Monitor Analysis Software Vibration Transmitters PCM360 Plant Condition Management System Vibration Meters Vibration Switches Mechanical- Electronic Performance Sensors

  4. General • PT2060 is designed for highest reliability with full integration as a monitor system • PT2060 is for critical machinery vibration protection • Steam turbines, gas turbines, large pumps, air separation etc. • PT2060 can replace most of the competitors system, such as 3500, VM600 etc.

  5. PT2060 Features • Flexible - It’s a modular system • Reliable – It’s a fully redundant system • Technology – Digital, PLC structure • Certification – CSA approval, Conform API 670 • Configuration – Fully software configurable

  6. PT2060 Features-1 • Highly reliable: • Each channel can achieve triple redundancy, 2 out of 3 voting • Grouped with 4 slots • Power supply redundant • Communication redundant: • 4-20mA on each channel with • Modbus and • Modbus redundant (/96) • Modbus TCP

  7. PT2060 Features-2 • Smart four channel module • Higher channel density • Up to 48 channels on each rack monitor (4 channels per module) • Channels can be programmed independently by pairs • Smart module • PT2060/10 • Thrust, vibration, speed, over-speed, reverse speed, zero speed, differential expansion, low speed vibration, eccentricity • PT2060/20 • Acceleration, velocity, displacement, absolute vibration, case expansion etc. • PT2060/31 • Virtually any temperature from TC or RTD

  8. PT2060 Features-3 • Internal bus communication • More advanced structure in monitoring • Better in data management • Structured for redundancy • Programmable alarms • Digital communication • Reliable data exchange

  9. PT2060 Features-4 • Independent 16 channel relay modules • ProvibTech is one of the few vibration companies that utilize the advanced internal bus structure • PLC/DCS type ladder alarm logic • Independent dual redundant on /43 redundant alarm module Can replace PLC for alarm programming • Can realize double or triple alarm redundancy with programming

  10. PT2060 Features-5 • System fully configurable by software • Configuration for monitor system, for modules and for channels • Configuration for more than one monitors • Compatible with Modbus protocol & Modbus TCP – Easy in future expansion, or 3rd party programming

  11. PT2060 Features-6 • Modbus communication port • Modbus and Modbus TCP can be accessed from PT2060/91 SIM • With RS485 or RS232 or Ethernet • Redundant Modbus and Modbus TCP is available • From different module, different hardware • Independent data access • More from Modbus /Ethernet port: • System configuration • Display unit interface • Monitors intercommunication

  12. PT2060 Features-7 • Meet or exceed API670 standard • For example: • Redundant power supply • Programmable alarms • Programmable alarm inhibit, alarm delay, trip-multiply etc. • Analog and digital communication port • Any measurement point can form triple redundant

  13. PT2060 Features-8 • Integrated condition monitoring (future release) • Condition monitoring slot(2) for transient or dynamic data analysis with PT2060/80 CM module • No further hardware is required for condition monitoring • PCM360 condition monitoring and database software is required for analysis and data storage • Buffered output for 3rd party interface

  14. System Components Minimum Requirement - 1 PT2060/99 Rack

  15. System Components Minimum Requirement - 2 PT2060/90 Power Supply Minimum Requirement - 1 PT2060/99 Rack

  16. System Components Minimum Requirement - 2 PT2060/90 Power Supply Minimum Requirement - 3 PT2060/91 SIM Minimum Requirement - 1 PT2060/99 Rack

  17. System Components Signal conditioning modules /10 Proximity /20 Seismic /31 Temperature /35 Process /53 Over speed

  18. Communication PT2060/40/43 Relay Modules System Components

  19. Communication PT2060/40/43 Relay Modules Communication PT2060/96/91 Modbus System Components

  20. Communication PT2060/40/43 Relay Modules Communication PT2060/96/91 Modbus Communication PT2060/36 4-20mA System Components

  21. Communication PT2060/40/43 Relay Modules Communication PT2060/96/91 Modbus Communication PT2060/36 4-20mA System Components Minimum Requirement - 2 PT2060/90 Power Supply Signal conditioning modules /10 Proximity /20 Seismic /31 Temperature /53 Over speed Minimum Requirement - 3 PT2060/91 SIM Minimum Requirement - 1 PT2060/99 Rack

  22. Output /96 Modbus /40/43 Relay /10/20/31 4-20mA /36 Transmitter /98 Display /91 Modbus RTU/TCP,SysOK

  23. PT2060 Modules Introduction • PT2060/10 PROX Proximity Module • PT2060/20 SEIS Seismic Module • PT2060/31 TEMP Temperature Module • PT2060/35 PROC Process Variable Module • PT2060/36 TRO Transmitter Output Module • PT2060/40 RELAY Module • PT2060/43 R-RELAY Redundant-Relay Module • PT2060/53 O-SPEED Over-speed Module • PT2060/80 CM Condition Monitoring Module • PT2060/90 POWER Power Supply Module • PT2060/91 SIM System Interface Module • PT2060/96 COMM Communication • PT2060/98 DISP Display System • PT2060/99 System Rack • PT2060-CFG System Configuration Software

  24. PT2060/10 PROX Proximity Module • PROX module will condition and process most of the proximity probe input signals. Includes • Radial vibration: • Monitoring shaft vibration, single or dual XY • Thrust position: • Monitoring shaft thrust position, with 5/8/11 mm proximity probes

  25. PT2060/10 PROX Proximity Module • Eccentricity: • Monitoring shaft eccentricity • Differential Expansion: • Monitoring turbine differential expansion • Low-frequency Vibration: • Monitoring low frequency machines. Such as hydro-turbine. Frequency start from 0.5Hz • Speed: • Monitoring rotation speed. • Monitoring zero speed • Monitoring reverse speed

  26. PT2060/10 TSI – Zero Speed • 1 - 255 events per revolution with a maximum full Zero speed is available – TSI function • Measuring speed up to 300 rpm. Zero speed channel will automatically convert to normal speed channels • Zero speed channel takes two normal vibration channels • Zero speed channel has two low speed alarms • Zero speed channel uses the 2nd channel for normal speed indication and protection with two high speed alarms

  27. PT2060/10 TSI – Reverse Rotation Protection • Reverse rotation will cause rotation machinery destruction! • Require two speed sensors (proximity) for this function • Capable of output normal speed data • Requiring multiple teeth wheel

  28. PT2060/10 TSI – Reverse Rotation Protection

  29. PT2060/20 AVD Seismic Vibration Module • AVD module will process most of the seismic input, and some other signals.

  30. PT2060/20 AVD Seismic Vibration Module • Acceleration and Velocity: • Any ICP type seismic sensors. Such as accelerometer, velocity sensors (TM0782A, TM0793V) • Velocity or Displacement: • Any electro-magnetic sensors. • Low frequency Displacement: • Any low frequency sensors (TM079VD etc) • Case Expansion: • LVDT • Complimentary Vibration: • Dual sensors includes proximity probes and velocity sensor • Integrator: • The module has an build-in integrator that will convert an input accelerometer signal to velocity or a velocity sensor input into a displacement.

  31. PT2060/20 LVDT single or dual inputs

  32. PT2060/31 Temperature Module RTD or Thermocouple RTD: PT100 3-wire & 4-wire NI120 3-wire & 4-wire CU10 3-wire & 4-wire TC: E, J, K, T • 8 Channels • No 4-20mA Output • Up to 4 set points per channel

  33. PT2060/31 Temperature Module • PT2060/31TEMP module replaces our existing PT2060/30 module. Upon the release of the new PT2060/31, the PT2060/30 is obsolete. Spare parts are available for two years. But no new order will accept PT2060/30. Compare with the old PT2060/30, PT2060/31 has some new features. • Input expanding to includes both thermo-couple(TC) and thermo-resistor (RTD) in 3-wire or 4-wire format • Inputs are optically isolated from system for better accuracy and noise immune • 24bit A/D conversion to assure high accuracy measurement • Eight channels signal inputs per module • Available in hot-insert • Front panel and back panel can be randomly selected. No matching is required. • Smart address to avoid system insertion error • Utilize a dedicated module for transmission of 4-20mA

  34. PT2060/35 PROC Process • PT2060/35 PROC Process Module accepts most process input. These process data will input into PT2060 system as part of the data stream together with vibration data for integral processing. • Accepts inputs such as 4-20mA, 0-20mA, 1-5V, 0-10V etc. • Optical isolated output from system. This is greatly enhanced the signal/noise ratio in some field application. • High accurate, stable 24bit A/D converter • Available in hot-insert • Front panel and back panel can be randomly selected. No matching is required. • Smart address to avoid system insertion error

  35. PT2060/36 TRO Output Module 16 4-20mA outputs Assignable to any channel’s full scale value Assignable to any channel’s GAP voltage

  36. PT2060/36 TRO Transmitter Module • PT2060/36 TRO transmitter module is our new module that adding flexibility to system output. PT2060/36 can be use in the following situation. • Additional programmable transmitter output. Each module contains 16 transmitters (source). Each transmitter can be programmed with either overall or gap of any channel. • Optical isolated output from system. This is greatly enhanced the signal/noise ratio in some field application. • High accurate, stable 16bit D/A converter • Available in hot-insert • Front panel and back panel can be randomly selected. No matching is required. • Smart address to avoid system insertion error

  37. PT2060/40 RELAY Relay module • RELAY module is a programmable relay module that can be programmed with any status parameters (alarms(2)/ok) of any channel. The status of all channels can be programmed with ladder logic. The function is similar to PLC functions. Each RELAY module hold up to 16 relays.

  38. PT2060/40 RELAY Relay module

  39. PT2060/43 R-RELAY Redundant Relay Module • R-RELAY module is a programmable relay module that can be programmed with any status parameters (alarms/ok) of any channel. The status of all channels can be programmed with ladder logic. The function is similar to PLC functions. Each R-RELAY module has two independent circuits that work independently.

  40. PT2060/53 O-Speed Overspeed Module • Each 3-SPEED module contains one speed channel. Three of the 3-SPEED module together with PT2060/43 redundant relay module and dual PT2060/90 power supply modules composes of a over-speed protection system. The system takes up total four slots. • Proximity probe & magnetic sensor

  41. PT2060/53 Magnetic Pickup • Magnetic speed sensor is available for over-speed measurement • 1 - 255 events per revolution with a maximum full scale range of 60000 RPM and a maximum input frequency of 10 kHz. Minimum input frequency for proximity transducers is 0.0167 Hz (1 RPM for 1 event/revolution) and for magnetic pickups (Speed signal conditioning only) is 3.3 Hz

  42. PT2060/53 O-Speed Overspeed Module with more channels • Two additional PROX channels on the bottom half of the module are available • These two channels are fully compatible with the PT2060/10 channels • Channel density of the system has been increased • For an over-speed system, total additional of six channels are available

  43. PT2060/53 O-Speed Overspeed Module with more channels Two additional proximity channels

  44. An over speed system

  45. PT2060/90 POWER Power Supply Module • POWER module includes two redundant half-height modules. Usually, one half-height power supply module is sufficient for normal operation. Power supply redundancy can be realized by uses both half-height modules.

  46. PT2060/91 SIM System Interface Module • System configuration: • Configure all the signal channels, system parameters, communication parameters, system, modules etc. • Modbus communication: • Communicate with PLC/DCS; control system reset, alarm multiply, alarm inhibit • Dual phase references: • Connect to phase reference proximity probe, and distribute the phase information over the system • Rack interconnection with communication • Modbus RTU/ Modbus TCP • System OK Relay • Storage: System Event, Alarm, Channel tag

  47. PT2060/96 COMM Communication Module • COMM module is a complimentary module in communication with Modbus. It has similar function as the communication part of SIM. The function and features: • Additional digital Modbus communication • Digital communication redundancy • Optional for PT2060/98 interface • Optional for PLC/DCS communication • Optional dual phase references

  48. PT2060/91/96 Modbus TCP Modbus TCP Ethernet port RJ45 Modbus RTU Serial Port RS232 RS485

  49. PT2060/91/96 Modbus TCP/RTU Compare • Each /91 or /96 has a hardware RJ45 port for Modbus TCP communication • Either Modbus TCP or Modbus RTU can be selected. Only one port among RJ45, RS232, RS485 can be selected in one module • Each /91 Ethernet port can have up to 5 host. Recommend one host per port. • Each /91 RS485/232 port can have only one host. • Ethernet has transmission distance up to 100 meters (300 feet). RS485 has 1000 meters (3000 feet), and RS232 has 3 meters (10 feet) • Ethernet is highly recommended for connection PT2060/98 display, or PT2060-CFG • 10Mbps, IEEE802.3

  50. PT2060/91 Modbus TCP for System Configuration

More Related