670 likes | 1.27k Views
PACKAGE UNITS. GPG 10 AND 12 SEER. TECHNICAL SUPPORT 888-593-9988. MARK STOKES 713-861-2500 EXT. 630. Model Number Chart. SERIAL NUMBER. 09 is for the month it was built. 0409456678. 04 is for the year it was built. 12 & 10 SEER Packaged Gas Electric . Fits in a standard size Pickup!.
E N D
PACKAGE UNITS GPG 10 AND 12 SEER
TECHNICAL SUPPORT888-593-9988 MARK STOKES 713-861-2500 EXT. 630
SERIAL NUMBER 09 is for the month it was built 0409456678 04 is for the year it was built
12 & 10 SEER Packaged Gas Electric Fits in a standard size Pickup! 47” Wide
12 & 10 SEER Packaged Gas Electric Cooling Features: • Convenient access panels to the compressor • High-efficiency Scroll and Energy-efficient reciprocating compressor. • Copper tube/aluminum fin coil. • Liquid line filter drier. • Fully charged R-22 system. • Louvered Guard Protection
10 & 12 SEER Packaged Gas Electric Control Features: • Convenient access panels to the Evaporator coil and control section. • Direct spark ignition system, which includes a microprocessor based control for the entire ignition sequence, all blower operation and all safety circuits. • Diagnostic Indicator provided for trouble shooting system faults.
Design Objectives • 2 – 5 ton Single Phase • 3, 4 & 5 ton Three Phase • 12 &10 SEER Cooling, 80% AFUE Heating • Capable of expansion to higher SEER ratings • Convertible • Easy Access Service Panels Architectural Gray
12 & 10 SEER Packaged Gas Electric Heating Features: • Convenient access panels to the heating section. • Redundant gas valve, natural gas and easy conversion to propane. • Power-assisted combustion. • L.P. Conversion Kit Available • 12 & 10 SEER units offer a durable, T-140 Aluminized Steel tubular heat exchanger. • California Low Nox Approved
Manufacturing stress including wall-thinning is minimized Wrinkles are placed precisely where we want them Wrinkles promote turbulence to aid heat transfer and efficiency Wrinkle-bend Process We begin with T-140 Aluminized Steel tubes
1-3/4” diameter fits inside a 1-1/4” diameter Tubes are joined with a proprietary process Velocity of combustion products is optimized Efficiency is maximized Dual-diameter/Muffler-joint We apply a patented process to join tubes
1,000°F 300°F Tubular Technology Renders Clamshell Obsolete 800°F 1,000°F 300°F 300°F 300°F 110°F • Non-uniform thermal growth • Eyelets can pop • Stress-cracks can form • Tube can grow in length and diameter • Growth is uniform at the cross-section • No opportunity for stress-cracks
12 & 10 SEER Packaged Gas Electric McDaniel Metals By Accessories
10 & 12 SEER Packaged Gas Electric Blower Features: • Convenient access panels to the blower section. • Filter rack included on 12 SEER large (4 &5 ton) chassis. • Easy removal of blower with two screws. • Multi-speed evaporator blower. • Fully insulated with blankets of fiberglass.
12 & 10 SEER Packaged Gas Electric Base Features: • 042 Aluminized Steel Bottom/Base Pan • 2” High Base Rails Shipped with four panels
Electrical • 208/230 Volt Power connections and 460 Volt available in 5 Ton Cool only model • Single Phase and Three phase models available • Maximum Over current Protection determined by model
Wiring • All wiring should be made in accordance with the National Electrical Code. • Wire sizes and over current protection should be determined from the unit nameplate ampacity. • Wire sizes should not be smaller than recommended by these two sources. • All exterior wiring must be within approved weatherproof conduit. • The unit must be permanently grounded in accordance with local codes.
CHECKING GAS PRESSURE Manifold Outlet Gas Pressure Natural…. Min. 3.2” W.C., Max 3.8” W.C. Propane….Min. 9.7” W.C., Max. 10.3” W.C.
Pressure Switch Check • Meter on AC Voltage Setting ; between Quick Connect on Pressure Switch and Ground • Prior to Operation check for open side of Pressure Switch (No Voltage Present) • When Pressure Switch Closes 24 Volts should be present on N/O side • Issue: Watch for switch bounce on windy days • Issue: Watch for P.S. drop-out for low pressure
Understanding ECM Motors • What does ECM mean? • How does the ECM work? • Variable Speed vs Constant Volume. • What is PWM • How does the ECM sense static pressure? • Troubleshooting ECM motors.