An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MAXSYSVersion 3.3 Integrated Systems Integrated Technology!

  2. MAXSYSVersion 3.3 Introduction The MAXSYS Panel: • Integrated Product with Single Software Design • Combines 4 Systems: • Burglary • Fire • Access Control • Automation • Full Upload/Download Programming • User-Friendly System Administration Software – DLS-3 SA

  3. MAXSYSVersion 3.3 Introduction Overview: • 16 Zone, Expandable to 128 • Hardwire, Wireless, Addressable Expansion • Maximum 16 LCD Keypads • 8 Partitions • 1500 User Codes • 3000 Event Buffer • Supervised Digital Communicator • 3 Phone Numbers, 9 Account Numbers • 1 Supervised Bell Output • Local Upload/Download with PCLINK Connector

  4. MAXSYSVersion 3.3 Hardwire Expansion Hardwire: • PC4108 Zone Expander • 8 Hardwire Zones • PC4116 Zone Expander • 16 Hardwire Zones • Connect any Number of Modules to Expand the System up to 128 Zones PC4108/4116

  5. MAXSYSVersion 3.3 Addressable Expansion Addressable: • Two-Wire Addressable Loop • PGM1 and PGM2 can both be used • Each can provide up to 170 mA of current • Connect up to 128 Addressable (AML) Detectors • Does not require any additional modules • Isolators and Repeaters Available • AML-770 Isolator Module • AMX-400 Isolator/Repeater Module

  6. MAXSYSVersion 3.3 Addressable Expansion Burglary Detectors AMB-300 Standard PIR AMB-500 Ceiling Mount PIR AMB-600 Pet Immune PIR AMA-100 Glassbreak Detector Fire Detectors AMP-700/701 Contact Modules AMS-220 Smoke Detector AMP-702 Fire Input Module

  7. MAXSYSVersion 3.3 Addressable Expansion Use 2-wire addressable loops to easily expand to full system capacity without the added cost of system expansion modules. AMS-220 AMB-500 AML-770 AMP-701 AMB-300 The AML-770 can be used to isolate fire detectors from burglary detectors so they can be connected to the same wire run. AMX-400 The AMX-400 can be used to repeat the data loop – allowing for longer wire runs. In addition, it will isolate the loop in the event of a problem. AMA-100 AMB-600

  8. MAXSYSVersion 3.3 Wireless Expansion Wireless: • Supports up to 64 Wireless Zones • Supports up to 16 Wireless Keys • Wireless keys do not use up zones • Uses the PC4164-433 MHz Wireless Receiver Module • Connect up to 8 PC4164-433 Modules for: • Distributed wireless reception • Larger coverage area • Allows users to move through larger area with wireless panic pendants and wireless keys without being out of range

  9. MAXSYSVersion 3.3 Wireless Expansion • Connect up to 8 PC4164-433 Modules • Total number of wireless zones is 64 • Total number of wireless keys is 16 WLS904PL Pet Immune Motion WLS906 Smoke Detector PC4164-433 Wireless Receiver WLS914 Pet Immune Motion WLS918 Panic Pendant WLS919 Wireless Key WLS912L Glassbreak Detector WLS925L Door/Window Contact WLS907T Low Temperature Sensor

  10. MAXSYSVersion 3.3 COMBUS COMBUS: • Bi-Directional RS-485 Communication Bus for Modules • Four wire, non-shielded cable • Red/Black for power, Yellow/Green for data • All Modules Connect to the COMBUS • Modules can be home run, daisy-chained, t-tapped • Total wire used cannot exceed 5,000 feet • Additional Power Supplies Available • PC4204 – power supply with 4 relay outputs • PC4204CX – power supply/COMBUS repeater with 4 relay outputs

  11. MAXSYSVersion 3.3 Modules

  12. MAXSYSVersion 3.3 Burglary Modules Keypads: • LCD4500 LCD Keypad • Programmable Alphanumeric Keypad • LCD4501 LCD Keypad • Programmable Alphanumeric Keypad • 5 Programmable Function Keys • Connect up to 16 Keypads Maximum

  13. MAXSYSVersion 3.3 Burglary Modules Zone Expanders: • PC4108 Zone Expander • 8 Hardwire Zones • PC4116 Zone Expander • 16 Hardwire Zones • Current Draw – 30 mA • AUX Output to Provide Power for Detectors

  14. MAXSYSVersion 3.3 Burglary Modules Output Modules: • PC4204 Power Supply • 1 Amp Power Supply • PC4204CX Power Supply • 1 Amp Power Supply (40 VA transformer) • 2.2 Amp Power Supply (80 VA transformer) • COMBUS Repeater • Modules Supervised for Low Battery, AC Failure and Aux Output Failure • Modules have 4 Programmable High Current Relays

  15. MAXSYSVersion 3.3 Burglary Modules Output Modules: • PC4216 Output Module • Provides 16 Low Current Outputs • Outputs Rated at 50 mA • Connect up to 9 Modules for 144 Outputs • Typically Used for Annunciation • PC4632 – 32 Point Annunciator • 8 ½ x 11 inch display area • PC4664 – 64 Point Annunciator • 11 x 17 inch display area

  16. MAXSYSVersion 3.3 Fire Modules Fire Features • All 128 Zones can be used for Fire • Hardwire or Addressable • Dual Phone Line Dialer Module • 24 VDC Notification Appliance Outputs • Annunciators • Auto-Scroll Alarms • Fire Inspector Test • User Initiated Fire Drill

  17. MAXSYSVersion 3.3 Fire Modules Keypads: • LCD4520 LCD Fire Keypad • Programmable Alphanumeric Keypad • LCD4521 LCD Fire Keypad • Programmable Alphanumeric Keypad • 5 Programmable Function Keys • Connect up to 16 Keypads Maximum

  18. MAXSYSVersion 3.3 Fire Modules Annunciators: • PC4612 Fire Annunciator • 10 Fire Zones, 2 Supervisory • Zone, Bell and System Trouble • AC Indicator • PC4632/PC4664 Annunciators • 32 or 64 Point Annunciators • Uses PC4216 Modules (up to 4)

  19. MAXSYSVersion 3.3 Fire Modules Dialer Module: • PC4701 Two Line Dialer Module • Includes: • Connection for two Separate Phone Lines • One 2-Wire, Class B/Style B Smoke Detector Zone • One Class B/Style B Waterflow Zone • Form ‘C’ Fire Alarm Relay • Form ‘C’ Fire Trouble Relay

  20. MAXSYSVersion 3.3 Fire Modules Output Module: • PC4702BP Bell Panel • Up to 4 Modules per System • Two Alarm Notification Outputs • 24 VDC, 1.8 Amps each • Outputs supervised • PTC Protected • Outputs will self-restore when problem corrected • Includes 28 Volt, 180 VA Transformer • Red Cabinet

  21. MAXSYSVersion 3.3 Fire Modules Power Supply: • PC4204CF Power Supply • Up to 16 Modules per System • Provide up to 1 Amp • Fully Supervised for: • Low battery, AC failure, AUX output failure • Four Programmable High Current Relays • Includes 16 Volt, 40 VA Transformer • Red Cabinet

  22. MAXSYSVersion 3.3 Fire Modules Battery Charger: • PC4350 External Battery Charger • Includes: • PC4085 Charger Module • Red Cabinet • 16 VAC, 80 VA Transformer • Used to Charge up to 60 Ah of Batteries • Auto Shutdown to Prevent Battery Deep Discharge • Supervised for AC Failure

  23. MAXSYSVersion 3.3 Access Control Features • Up to 32 Readers • 1500 Users • 64 Access Levels • 99 Date Schedules, 4 Interval Each • 4 Holiday Groups • Scheduled Options Including: • Door Unlock • REX Input • Code Required • Door Forced • Door Open Too Long • Arm Request • Disarm Request

  24. MAXSYSVersion 3.3 Access Control Modules Controller: • PC4820 Access Control Module • Up to 16 Modules per Panel • Each module supports up to 2 Readers • Supervised Lock Output Power, 250 mA • Inputs: • Door Contact, REX, Arm and Postpone Arm • Outputs: • LED, Buzzer • ‘Failsoft’ Operation • Operates if communication is lost with control panel

  25. MAXSYSVersion 3.3 Access Control Modules Readers: • Multiple Reader Technology Support: • Polaris • ShadowProx • HID • IoProx • Different Technology Readers can be used on one System

  26. MAXSYSVersion 3.3 Access Control Modules Controller: • PC4850 Lobby Controller • Apartment Building Entry Control • Gate Control • Up to 16 Modules per Panel • Electronic Directory up to 1500 Users • Controls up to 2 Doors • ‘Failsoft’ Operation • Operates if communication is lost with control panel • Internal 128 Event Buffer • PC4851 ‘No Phone Bill’ Option

  27. MAXSYSVersion 3.3 Automation Features • Telephone Interface • Control panel using any touchtone telephone • Interface for Power Line (X-10) Devices • Intercom • Verbal Chime • Verbal Alarm

  28. MAXSYSVersion 3.3 Automation Modules Telephone Interface • Escort4580 Telephone Interface Module • Turns any Touchtone Telephone into a Talking Keypad • Local or Remote Access • Multiple Language Available • Get Verbal System Status • Arm, Disarm and Perform Other User Functions • 240 Word Library for Labels (zones, partitions, automation items) • Interface for Power Line (X-10) Devices • Control up to 32 Automation Devices

  29. MAXSYSVersion 3.3 Automation Modules Intercom • PC4936 Intercom Module • 7 Station Intercom Module • Indoor and Outdoor (doorbell) Stations Available • Features Include Page/Answer, Doorbell, Do not Disturb • Supports Central Station Listen-In and Two-Way • Expandable to 15 Stations with PC4937 Module • When used with Escort4580 Features Include: • Verbal Door Chime • Verbal Alarm Annunciation

  30. MAXSYSVersion 3.3 Miscellaneous Features • DataLink • Bi-Directional RS232 Control • Alternate Communications • Skyroute • T-Link • Downloading

  31. MAXSYSVersion 3.3 DataLink DataLink • PC4401 Serial Interface Module • Supports Bi-Directional RS232 Control • Provides System Integrators with Real-Time Events • Panel will send panel status real-time • Provides System Integrators with Real-Time Control • Commands can be sent to the panel such as arm, disarm and bypass

  32. MAXSYSVersion 3.3 Cellemetry Communicator Cellemetry Communicator • SkyrouteMAX Cellemetry Communicator • Redundant Alarm Communication via Cellemetry Data Service • Uses Control Channel of Existing Cellular Network • Connects Directly to Panel COMBUS • Can Report all Events by User Code, Zone • Fully Supervised • Signal Strength Indicator

  33. MAXSYSVersion 3.3 Network Interface T-Link Module • T-Link TCP/IP Module • Connects to Panel PCLINK Connector • Used on LAN or WAN of User • Can be used with Reporter IP Software for Local Reporting • Can be used with Sur-Gard Receiver to Report via Network to the Central Station • Can be used for End User Downloading

  34. MAXSYSVersion 3.3 Miscellaneous UL Listings: • UL365, UL1635 Police station alarm units (Commercial burglary) • UL1610, UL1635 Central station alarm units (Commercial burglary) • UL609, UL1635 Local alarm units (Commercial burglary) • UL1023 Household burglar alarm system units • UL985 Control units & accessories - Household system • UL864 Control units system (Commercial Fire) • UL294 Access control system units International Listings: • CE – EN60950; EN50130-4; EN55022 • Class B • CTR-21 • CSFM

  35. MAXSYSVersion 3.3 Summary Dealer Benefits: • Secure larger portion of installation • One system to learn and maintain • Opportunity for post-installation expansion sales • Lower system cost + simplified installation = HIGHER PROFITS • Third party system integration End User Benefits: • Product grows with customer’s changing needs • One system to learn - plain language keypads • One installer to call = reduced maintenance headaches • Most cost-effective multiple system solution • Windows™-based System Administration Software