MAXSYSVersion 3.3 Integrated Systems Integrated Technology!
MAXSYSVersion 3.3 Introduction The MAXSYS Panel: • Integrated Product with Single Software Design • Combines 4 Systems: • Burglary • Fire • Access Control • Automation • Full Upload/Download Programming • User-Friendly System Administration Software – DLS-3 SA
MAXSYSVersion 3.3 Introduction Overview: • 16 Zone, Expandable to 128 • Hardwire, Wireless, Addressable Expansion • Maximum 16 LCD Keypads • 8 Partitions • 1500 User Codes • 3000 Event Buffer • Supervised Digital Communicator • 3 Phone Numbers, 9 Account Numbers • 1 Supervised Bell Output • Local Upload/Download with PCLINK Connector
MAXSYSVersion 3.3 Hardwire Expansion Hardwire: • PC4108 Zone Expander • 8 Hardwire Zones • PC4116 Zone Expander • 16 Hardwire Zones • Connect any Number of Modules to Expand the System up to 128 Zones PC4108/4116
MAXSYSVersion 3.3 Addressable Expansion Addressable: • Two-Wire Addressable Loop • PGM1 and PGM2 can both be used • Each can provide up to 170 mA of current • Connect up to 128 Addressable (AML) Detectors • Does not require any additional modules • Isolators and Repeaters Available • AML-770 Isolator Module • AMX-400 Isolator/Repeater Module
MAXSYSVersion 3.3 Addressable Expansion Burglary Detectors AMB-300 Standard PIR AMB-500 Ceiling Mount PIR AMB-600 Pet Immune PIR AMA-100 Glassbreak Detector Fire Detectors AMP-700/701 Contact Modules AMS-220 Smoke Detector AMP-702 Fire Input Module
MAXSYSVersion 3.3 Addressable Expansion Use 2-wire addressable loops to easily expand to full system capacity without the added cost of system expansion modules. AMS-220 AMB-500 AML-770 AMP-701 AMB-300 The AML-770 can be used to isolate fire detectors from burglary detectors so they can be connected to the same wire run. AMX-400 The AMX-400 can be used to repeat the data loop – allowing for longer wire runs. In addition, it will isolate the loop in the event of a problem. AMA-100 AMB-600
MAXSYSVersion 3.3 Wireless Expansion Wireless: • Supports up to 64 Wireless Zones • Supports up to 16 Wireless Keys • Wireless keys do not use up zones • Uses the PC4164-433 MHz Wireless Receiver Module • Connect up to 8 PC4164-433 Modules for: • Distributed wireless reception • Larger coverage area • Allows users to move through larger area with wireless panic pendants and wireless keys without being out of range
MAXSYSVersion 3.3 Wireless Expansion • Connect up to 8 PC4164-433 Modules • Total number of wireless zones is 64 • Total number of wireless keys is 16 WLS904PL Pet Immune Motion WLS906 Smoke Detector PC4164-433 Wireless Receiver WLS914 Pet Immune Motion WLS918 Panic Pendant WLS919 Wireless Key WLS912L Glassbreak Detector WLS925L Door/Window Contact WLS907T Low Temperature Sensor
MAXSYSVersion 3.3 COMBUS COMBUS: • Bi-Directional RS-485 Communication Bus for Modules • Four wire, non-shielded cable • Red/Black for power, Yellow/Green for data • All Modules Connect to the COMBUS • Modules can be home run, daisy-chained, t-tapped • Total wire used cannot exceed 5,000 feet • Additional Power Supplies Available • PC4204 – power supply with 4 relay outputs • PC4204CX – power supply/COMBUS repeater with 4 relay outputs
MAXSYSVersion 3.3 Modules
MAXSYSVersion 3.3 Burglary Modules Keypads: • LCD4500 LCD Keypad • Programmable Alphanumeric Keypad • LCD4501 LCD Keypad • Programmable Alphanumeric Keypad • 5 Programmable Function Keys • Connect up to 16 Keypads Maximum
MAXSYSVersion 3.3 Burglary Modules Zone Expanders: • PC4108 Zone Expander • 8 Hardwire Zones • PC4116 Zone Expander • 16 Hardwire Zones • Current Draw – 30 mA • AUX Output to Provide Power for Detectors
MAXSYSVersion 3.3 Burglary Modules Output Modules: • PC4204 Power Supply • 1 Amp Power Supply • PC4204CX Power Supply • 1 Amp Power Supply (40 VA transformer) • 2.2 Amp Power Supply (80 VA transformer) • COMBUS Repeater • Modules Supervised for Low Battery, AC Failure and Aux Output Failure • Modules have 4 Programmable High Current Relays
MAXSYSVersion 3.3 Burglary Modules Output Modules: • PC4216 Output Module • Provides 16 Low Current Outputs • Outputs Rated at 50 mA • Connect up to 9 Modules for 144 Outputs • Typically Used for Annunciation • PC4632 – 32 Point Annunciator • 8 ½ x 11 inch display area • PC4664 – 64 Point Annunciator • 11 x 17 inch display area
MAXSYSVersion 3.3 Fire Modules Fire Features • All 128 Zones can be used for Fire • Hardwire or Addressable • Dual Phone Line Dialer Module • 24 VDC Notification Appliance Outputs • Annunciators • Auto-Scroll Alarms • Fire Inspector Test • User Initiated Fire Drill
MAXSYSVersion 3.3 Fire Modules Keypads: • LCD4520 LCD Fire Keypad • Programmable Alphanumeric Keypad • LCD4521 LCD Fire Keypad • Programmable Alphanumeric Keypad • 5 Programmable Function Keys • Connect up to 16 Keypads Maximum
MAXSYSVersion 3.3 Fire Modules Annunciators: • PC4612 Fire Annunciator • 10 Fire Zones, 2 Supervisory • Zone, Bell and System Trouble • AC Indicator • PC4632/PC4664 Annunciators • 32 or 64 Point Annunciators • Uses PC4216 Modules (up to 4)
MAXSYSVersion 3.3 Fire Modules Dialer Module: • PC4701 Two Line Dialer Module • Includes: • Connection for two Separate Phone Lines • One 2-Wire, Class B/Style B Smoke Detector Zone • One Class B/Style B Waterflow Zone • Form ‘C’ Fire Alarm Relay • Form ‘C’ Fire Trouble Relay
MAXSYSVersion 3.3 Fire Modules Output Module: • PC4702BP Bell Panel • Up to 4 Modules per System • Two Alarm Notification Outputs • 24 VDC, 1.8 Amps each • Outputs supervised • PTC Protected • Outputs will self-restore when problem corrected • Includes 28 Volt, 180 VA Transformer • Red Cabinet
MAXSYSVersion 3.3 Fire Modules Power Supply: • PC4204CF Power Supply • Up to 16 Modules per System • Provide up to 1 Amp • Fully Supervised for: • Low battery, AC failure, AUX output failure • Four Programmable High Current Relays • Includes 16 Volt, 40 VA Transformer • Red Cabinet
MAXSYSVersion 3.3 Fire Modules Battery Charger: • PC4350 External Battery Charger • Includes: • PC4085 Charger Module • Red Cabinet • 16 VAC, 80 VA Transformer • Used to Charge up to 60 Ah of Batteries • Auto Shutdown to Prevent Battery Deep Discharge • Supervised for AC Failure
MAXSYSVersion 3.3 Access Control Features • Up to 32 Readers • 1500 Users • 64 Access Levels • 99 Date Schedules, 4 Interval Each • 4 Holiday Groups • Scheduled Options Including: • Door Unlock • REX Input • Code Required • Door Forced • Door Open Too Long • Arm Request • Disarm Request
MAXSYSVersion 3.3 Access Control Modules Controller: • PC4820 Access Control Module • Up to 16 Modules per Panel • Each module supports up to 2 Readers • Supervised Lock Output Power, 250 mA • Inputs: • Door Contact, REX, Arm and Postpone Arm • Outputs: • LED, Buzzer • ‘Failsoft’ Operation • Operates if communication is lost with control panel
MAXSYSVersion 3.3 Access Control Modules Readers: • Multiple Reader Technology Support: • Polaris • ShadowProx • HID • IoProx • Different Technology Readers can be used on one System
MAXSYSVersion 3.3 Access Control Modules Controller: • PC4850 Lobby Controller • Apartment Building Entry Control • Gate Control • Up to 16 Modules per Panel • Electronic Directory up to 1500 Users • Controls up to 2 Doors • ‘Failsoft’ Operation • Operates if communication is lost with control panel • Internal 128 Event Buffer • PC4851 ‘No Phone Bill’ Option
MAXSYSVersion 3.3 Automation Features • Telephone Interface • Control panel using any touchtone telephone • Interface for Power Line (X-10) Devices • Intercom • Verbal Chime • Verbal Alarm
MAXSYSVersion 3.3 Automation Modules Telephone Interface • Escort4580 Telephone Interface Module • Turns any Touchtone Telephone into a Talking Keypad • Local or Remote Access • Multiple Language Available • Get Verbal System Status • Arm, Disarm and Perform Other User Functions • 240 Word Library for Labels (zones, partitions, automation items) • Interface for Power Line (X-10) Devices • Control up to 32 Automation Devices
MAXSYSVersion 3.3 Automation Modules Intercom • PC4936 Intercom Module • 7 Station Intercom Module • Indoor and Outdoor (doorbell) Stations Available • Features Include Page/Answer, Doorbell, Do not Disturb • Supports Central Station Listen-In and Two-Way • Expandable to 15 Stations with PC4937 Module • When used with Escort4580 Features Include: • Verbal Door Chime • Verbal Alarm Annunciation
MAXSYSVersion 3.3 Miscellaneous Features • DataLink • Bi-Directional RS232 Control • Alternate Communications • Skyroute • T-Link • Downloading
MAXSYSVersion 3.3 DataLink DataLink • PC4401 Serial Interface Module • Supports Bi-Directional RS232 Control • Provides System Integrators with Real-Time Events • Panel will send panel status real-time • Provides System Integrators with Real-Time Control • Commands can be sent to the panel such as arm, disarm and bypass
MAXSYSVersion 3.3 Cellemetry Communicator Cellemetry Communicator • SkyrouteMAX Cellemetry Communicator • Redundant Alarm Communication via Cellemetry Data Service • Uses Control Channel of Existing Cellular Network • Connects Directly to Panel COMBUS • Can Report all Events by User Code, Zone • Fully Supervised • Signal Strength Indicator
MAXSYSVersion 3.3 Network Interface T-Link Module • T-Link TCP/IP Module • Connects to Panel PCLINK Connector • Used on LAN or WAN of User • Can be used with Reporter IP Software for Local Reporting • Can be used with Sur-Gard Receiver to Report via Network to the Central Station • Can be used for End User Downloading
MAXSYSVersion 3.3 Miscellaneous UL Listings: • UL365, UL1635 Police station alarm units (Commercial burglary) • UL1610, UL1635 Central station alarm units (Commercial burglary) • UL609, UL1635 Local alarm units (Commercial burglary) • UL1023 Household burglar alarm system units • UL985 Control units & accessories - Household system • UL864 Control units system (Commercial Fire) • UL294 Access control system units International Listings: • CE – EN60950; EN50130-4; EN55022 • Class B • CTR-21 • CSFM
MAXSYSVersion 3.3 Summary Dealer Benefits: • Secure larger portion of installation • One system to learn and maintain • Opportunity for post-installation expansion sales • Lower system cost + simplified installation = HIGHER PROFITS • Third party system integration End User Benefits: • Product grows with customer’s changing needs • One system to learn - plain language keypads • One installer to call = reduced maintenance headaches • Most cost-effective multiple system solution • Windows™-based System Administration Software