An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DDS-3 Back-upParameter Optimization San Jose State University ISE 202 Donald Kerns 12/7/2001

  2. DDS-3 Back-up Parameter Optimization • Problem Statement: • Current weekly server back-ups are taking ~15 hours. • This reduces maximum possible server availability and eats into productive time. • Goal/Objective Statement: • Back-ups to take no longer than 8 hours/week (can happen completely overnight). • Increase maximum possible server availability from 92% to >= 95%. • Projected Business Benefits: • Roughly $55K/year in labor savings. • Team: • Donald Kerns

  3. Design • 23 (2 replicates) • no confounding • On/Off nature of compression made center points problematic • Literature claimed a 5% effect of FIFO size • 16 runs ~= 9 hours • fits overnight

  4. Data and Analysis Fractional Factorial Fit: Time versus Compression, Block Size, FIFO Size Estimated Effects and Coefficients for Time (coded units) TermEffectCoefP Constant 783.6 0.000 Compression -265.0 -132.5 0.000 Block Size -603.2 -301.6 0.000 FIFO Size -7.0 -3.5 0.398 Compress*Block Si -8.8 -4.4 0.290 Compress*FIFO Siz 2.4 1.2 0.765 Block Si*FIFO Siz 9.0 4.5 0.280 Compress*Block Si*FIFO Siz -2.3 -1.1 0.779

  5. Analysis (cont) • Initial result • FIFO Size not significant • Compression should be on • Further investigate block size • Chose factor of 2 block sizes • Plot speed vs. size • Highest speed starts at 32KB

  6. Conclusions • New settings: • Increase maximum server availability from 91% to 98%. • Allow back-ups to be completely performed overnight.