140 likes | 152 Views
External features include a flow monitor, pump modulation, modular design, and various input signals. The pump has a large illuminated LCD display, easy calibration, programmable pressure levels, and optical indication of operation status.
E N D
Gamma/L Solenoid driven metering pump
Gamma/L • External features • Flow Monitor • Pump modulation • Input signals • Modular Design • Information key • Control cable • Menu Design • 4-20 mA input
External Features • Large illuminated LC display • Flow monitor with adjustable number of maximum error strokes up to 125 • Quick change of display information with I key • Easy calibration with warning when leaving the calibrated range • Programmable pressure levels • Optical indication of operation status • Cable recognition • Electronic interlocking of key pad by access code Fault occurred A condition that could lead to a fault Normal operation
Stop Stop Analog 12 Contact 226 mA N Stop Stop Manual Manual 180 Freq. 70 % Pump modulation • External control via voltage free contact with optional pulse multiplier/divider • Continuous stroke length adjustment from 0-100%, display in 1%-steps on LCD • External control via standard 0/4-20 mA • Digitally accurate stroking rate via keypad
Input Signals • Control Cable Remote Start/Stop Analog input (mA) Pulse input/Batch Take over frequency • Flow monitor input • Two stage float input
Control Cable Pause Pulse input Common - Auxiliary frequency Analog +
Modular Design • Universal power supply • One size of housing • Removable power cord • Retrofittable relays • Combination of relays • Fault indication relay+ • Pacing relay
i Information key • Permanent Display • Stroke frequency • Stroke length • Stroke counter • Capacity [gph or L/h] • Dosing quantity [gal or L] • Reset strokes • Reset [gallons or liters] • mA current • Pulse control / Memory • Indication of external mode
Liquid end material combination Materials Polypropylene/EPDM Polypropylene/Viton PVC/EPDM PVC/Viton Acrylic PVC/EPDM Acrylic PVC/Viton PTFE Stainless steel /PTFE PVDF/PTFE Feature PPE PPB PCE PCB NPE NPB TTT SST PVT
Capacities Version PSIG GPH ml/strk Strk/min Connect Suction Lift (ft) 1000 145 0.19 0.07 180 1/4 x 3/16 19.7 1601 253 0.29 0.10 180 1/4 x 3/16 19.7 1602 253 0.55 0.19 180 1/4 x 3/16 19.7 1005 145 1.1 0.41 180 1/2 x 3/8 16.4 0708 101 1.9 0.66 180 1/2 x 3/8 13.1 0413 58 3.2 1.14 180 1/2 x 3/8 9.8 0220 29 5.0 1.76 180 1/2 x 3/8 6.5 Auto-degassing Liquid Ends Version PSIG GPH ml/strk Strk/min Connect Suction Lift (ft) 1601 253 0.16 0.06 180 1/4 x 3/16 5.9 1602 253 0.37 0.13 180 1/4 x 3/16 6.9 1005 145 0.95 0.33 180 1/2 x 3/8 8.8 0708 101 1.76 0.61 180 1/2 x 3/8 6.5 0413 58 2.8 1.00 180 1/2 x 3/8 8.2 0220 29 4.3 1.50 180 1/2 x 3/8 6.5
Capacities Version PSIG GPH ml/strk Strk/min Connect Suction Lift (ft) 1605 253 1.1 0.38 180 1/2 x 3/8 13.1 1008 145 1.8 0.63 180 1/2 x 3/8 9.8 0713 101 2.9 1.02 180 1/2 x 3/8 9.8 0420 58 4.5 1.58 180 1/2 x 3/8 9.8 0232 29 8.4 2.96 180 1/2 x 3/8 6.5 Auto-degassing Liquid Ends Version PSIG GPH ml/strk Strk/min Connect Suction Lift (ft) 1605 253 0.87 0.31 180 1/2 x 3/8 9.8 1008 145 1.66 0.58 180 1/2 x 3/8 9.8 0713 101 2.77 0.97 180 1/2 x 3/8 8.2 0420 58 4.12 1.44 180 1/2 x 3/8 8.2
Other Features • High Viscosity Liquid Ends • PVDF • With valve springs • Viscosity up to 3000 Centipoises • Types 1005/1605, 0708/1008, 0413/0713 and 0220/0420 • Low Voltage Version • 12-24 VDC and 24 V AC/DC • Available for all pump types
Other Features • 2 Week Timer Gamma/L • Approx. 80 programmable events • Works as a real-time 2 week timer • 1 hour,1 day, 1 working week, 1 weekend, 1 week and 2 week periods programmable or works as a program, started e.g. by a contact • switch-on-times from 1 second to 2 weeks possible • programmable function of 2 relays • programmable change of operation mode • all functions independent from each other
New Style Flow Monitor • Higher reliability • Reduction of number of versions • Extended range of application • Material: PVDF/EPDM PVDF/VITON