QUALIFICATION External Instruments & more Somegeneralideas as an introduction • Qualification tests: to confirm the performances of the system in itsspecified operating conditions • Equipmentsused for qualification tests shouldberepresentative of production models in term of design, • dimensions, materials and manufacturingprocesses • As an (extra-ordinary) alternative someevidencesshouldbeprovidedthat the sytemwillperform as • specified • If a productundergoesany changes, the impact on performances shouldbedocumented • Substantive change becomes new design thatrequirere-qualification Qualification - Sylvain Henry Februay 1st 2018
QUALIFICATION Externalinstruments & more… • LBL Beacon • 2 items dedicated to qualification • Hydrophone • 2 items dedicated to qualification • Laser Beacon • 2 devices to beproduced • No one dedicated to qualification • BPS V02 (DU ORCA, ORCA, CB) • Calibration Base • As the ORCA base module • Instrumentation Unit • Deployment/recoverymethod to bequalified • once defined in details • Cylinder (ANTARES LCM like). • New Infrastructure IT Tentative of harmonization of the qualification procedure Qualification - Sylvain Henry Februay 1st 2018
QUALIFICATION General guide line As presented at the SC last days – seenext slide for update Qualification - Sylvain Henry Februay 1st 2018
QUALIFICATION TESTS PROGRAM (SUMMARY) Qualification - Sylvain Henry Februay 1st 2018
QUALIFICATION Reminder of the ORCA base module stress tests • Followingprocedure « MIL STD 810F »: originallymilitary but variant adapted to civil business • TEST PROGRAM: • Atmospheric conditioning: -10°C & +50°C/93%HR (12h + 12h) • Vibrations: (Rem:1h # 1600km) • Random(all the frequencies at the sametime) ismore realistic • Transversal skipped because of muchlowerconstraint? • 2 configurations: • > In transportation box: • 1h30 duration • > Mounted on « anchor » support • 0h30 min duration • Shocks: • ±3shocks ½ sine 15G/11ms → representative of real shock (hard but rare) • ±500 shocks ½ sine 10G/16ms → representative of shake (soft but repeated) • In the same 2 configurations mentionedabove • Transversal skipped because of muchlowerconstraint? signal average powerin 1Hz frequency band Total power transfered to the object Qualification - Sylvain Henry Februay 1st 2018
QUALIFICATION Pressure test guideline Qualification - Sylvain Henry Februay 1st 2018