Results of Imperium Testing Prepared for Chronix By Chris Moody
JFE • We received two samples from Chronix on behalf of JFE • Both samples were made of iron • The rectangle had a depth of 10.5mm and the square a depth of 16mm. • Flat bottom holes were detected in the rectangle using Pulse Echo testing. • Defects were found in the side walls of the square sample using Shear Wave testing.
JFE Square This test was performed using a 19 degree angle of incidence to record the defects shown in the side wall of this picture.
JFE Square This test was performed using a 18 degree angle of incidence to record the defect shown in the side wall of this picture.
JFE Square This test was performed using a 21 degree angle of incidence to record the defects shown in the side wall of this picture.
JFE Square This test was performed using a 21 degree angle of incidence to record the defects shown in the side wall of this picture.