170 likes | 245 Views
Results of Imperium Testing Prepared for Chronix. By Chris Moody. JFE. We received two samples from Chronix on behalf of JFE Both samples were made of iron The rectangle had a depth of 10.5mm and the square a depth of 16mm.
E N D
Results of Imperium Testing Prepared for Chronix By Chris Moody
JFE • We received two samples from Chronix on behalf of JFE • Both samples were made of iron • The rectangle had a depth of 10.5mm and the square a depth of 16mm. • Flat bottom holes were detected in the rectangle using Pulse Echo testing. • Defects were found in the side walls of the square sample using Shear Wave testing.
JFE Square This test was performed using a 19 degree angle of incidence to record the defects shown in the side wall of this picture.
JFE Square This test was performed using a 18 degree angle of incidence to record the defect shown in the side wall of this picture.
JFE Square This test was performed using a 21 degree angle of incidence to record the defects shown in the side wall of this picture.
JFE Square This test was performed using a 21 degree angle of incidence to record the defects shown in the side wall of this picture.