An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. english © 2006 marksa

  2. its activities contacts the company MARKSA: A WORLD OFENERGIESMARKSA is a company active in the areas of compressed air, vacuum, industrial refrigeration and air-conditioning.MARKSA is a manufacturer of machine coolers and chilled water production units that specialises in providing customised systems to meet the expectations of any customer.MARKSA, being an official agent of ATLAS COPCO (the World’sNo.1), analyses, designs and installs your networkand ensures the follow-up and maintenance of all installations relatingto compressed air.The identical services are available in the area of vacuum technologies wherewe are associated with the company of Rietschle Tomas. REFRIGERATION AFTER-SALES SERVICE © 2007 marksa

  3. its activities contacts the company MARKSA: A CONTROLLED WORLDOur job is to guarantee the stable temperature of a process in the medical, chemical, foodstuffs or other industry.We are the first company to which machine-tool manufacturers turn when they need to have the temperature of their spindles, oil vats, electrical equipment boxes, etc. stabilised. We also cool furnaces, lasers and even automatic drink distributors.To meet the requirements of our many customers, our workshops manufacture our coolers paying particular attention to the ecological criteria of the modern age, reliability, and not forgetting competitiveness.OUR PRODUCTSOur standard CSW type or customised CPW water chillers and CSO and CPO oil units, our GH heat-exchangers and our CST stabilisers come as compact units ready for use.They are intended to maintain the temperature of a liquid using a digital thermostat and display.They are of simple manufacture and allow for effective cooling at a very competitive price.They meet current European safety and environmental standards. REFRIGERATION WATER CHILLERS OIL CHILLERS EXCHANGER SYSTEMS CUSTOMISED GROUPS STABILISING GROUPS © 2007 marksa

  4. its activities contacts the company CSW 50-65 & 80 WATER CHILLERSDESIGN FEATURESPower: 0.5 kW - 0.65 kW - 0.80 kW at 20° CDimensions: 305 x 560 x 320 mmStainless steel water tank: 8 litresNoise level: 48 dB(A) - 250HzVoltage: 1 x 230 VoltsTemperature stability: +/- 1° CADVANTAGESCompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOPTIONS AVAILABLEF : Water-flow controllerI : Thermal insulationM : Frame on castersN : Water-level controlS : Safety pressure controllers REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  5. its activities contacts the company CSW 100 WATER CHILLER DESIGN FEATURES Power : 1.2 kW at 20° CDimensions: 360 x 600 x 385 mmStainless steel water tank: 8 litresNoise level: 49 dB(A) - 250 HzVoltage: 1 x 230 Volts Temperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOPTIONS AVAILABLE F : Water-flow controllerI : Thermal insulationM : Frame on castersN : Water-level controlR : Reinforced pumpS : Safety pressure controllersV : Visual water-level indicator REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  6. its activities contacts the company CSW 150-200 & 300 WATER CHILLERS DESIGN FEATURES Power: 1.5 kW - 2.3 kW - 3 kW at 20° CDimensions: 435 x 525 x 580 mmStainless steel water tank : 21 litresNoise level: 50 dB(A) 250 HzVoltage: 1 x 230 Volts - 3 x 400 VoltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOPTIONS AVAILABLE F : Water-flow controllerI : Thermal insulationM : Frame on castersN : Water-level controlR : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  7. its activities contacts the company CSW 400 WATER CHILLER DESIGN FEATURES Power: 4 kW at 20° CDimensions: 480 x 570 x 830 mmStainless steel water tank: 35 litresNoise level: 55 dB(A) - 250 HzVoltage: 3 x 400 VoltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOPTIONS AVAILABLE F : Water-flow controllerI : Thermal insulationM : Frame on castersN : Water-level controlR : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  8. its activities contacts the company CSW 600 & 800 WATER CHILLERS DESIGN FEATURES Power: 6 and 8 kW at 20° CDimensions: 600 x 650 x 1080 mmStainless steel water tank: 55 litresNoise level: 58 db(A) - 250 HzVoltage: 3 x 400 VoltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOverhead hot air evacuationOPTIONS AVAILABLE A : Metal air filtersF : Water-flow controllerI : Thermal insulationM : Frame on castersR : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  9. its activities contacts the company CSW 900-1000-1300 & 1700 WATER CHILLERS DESIGN FEATURES Power: 9 kW - 10 kW - 13 kW and 17 kW at 20° CDimensions: 700 x 850 x 1300 mmStainless steel water tank: 145 litresNoise level: 65 dB(A) - 250 HzVoltage: 3 x 400 VoltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOverhead hot air evacuationOPTIONS AVAILABLE A : Metal air filtersF : Water-flow controllerI : Thermal insulationR : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  10. its activities contacts the company CSW 2000 & 2400 WATER CHILLERS DESIGN FEATURES Power: 20 kW andt 24 kW at 20° CDimensions: 700 x 1240 x 1300 mmStainless steel water tank: 145 litresNoise level: 66 dB(A) - 250 HzVoltage: 400 voltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOverhead hot air evacuationOPTIONS AVAILABLE A : Metal air filtersF : Water-flow controllerI : Thermal insulationP : Pressurised hydraulic system R : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  11. its activities contacts the company CSW 3000 & 3500 WATER CHILLERS DESIGN FEATURES Power: 30 kW and 35 kW at 20° CDimensions: 900 x 1400 x 1300 mmStainless steel water tank: 145 litresNoise level: 67 dB(A) - 250 HzVoltage: 3 x 400 voltsTemperature stability: +/- 1° CADVANTAGES CompactnessNoise levelImmersed pumpNo hydraulic pipeWater circuit 100% no ferrous EcologicalOPTIONS AVAILABLE A : Metal air filtersF : Water-flow controllerI : Thermal insulationP : Pressurised hydraulic system R : Reinforced pump REFRIGERATION WATER CHILLERS 0.5-0.8 kW 1 kW 1.5-3 kW 4 kW 6-8 kW 9-17 kW 20-24 kW 30-35 kW © 2007 marksa

  12. its activities contacts the company CSO STANDARD RANGE The CSO product family is identical to the CSW series except thatthe liquid to be cooled is oil rather than water.The immersed pump as well as the evaporator (exchanger) are adapted in order to compensate for the fundamental differences of viscosity and specific heat between these two fluids.For the technical details, return to the REFRIGERATION OIL CHILLERS standard CSO range customised CPO range water chillers. © 2007 marksa

  13. its activities contacts the company CUSTOMISED CPO RANGEAs its name indicates, we are able to adapt to the demands of any specifications to satisfy your requirements by adding options to our refrigerating component, thereby customising your equipment. REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  14. its activities contacts the company CPO 140 OIL CHILLERDESIGN FEATURES Power: 1.4 kW for oil at 20° CDimensions: 360 x 600 x 385 mmNoise level: 52 dB(A) - 250 HzVoltage: 1 x 230 VoltsTemperature stability: +/- 1° CADVANTAGESCompactnessStainless steel, sulphur-oil-resistant exchangerEcologicalCustomisationpossible Keen priceOPTIONS AVAILABLE C : Integral certifugal pumpsF : Oil-flow controllerH : Heatiny M : Frame on castersS : Safety pressure controllersT : Programmingclock REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  15. its activities contacts the company CPO 210-310 OIL CHILLERSDESIGN FEATURES Power: 2.3 et 3 kW for oil at 20° CDimensions: 435 x 525 x 450 mmNoise level: 50 dB(A) 250 HzTension: 1 x 230 Volts - 3 x 400 VoltsTemperature stability: +/- 1° CADVANTAGESCompactnessStainless steel, sulphur-oil-resistant exchangerEcologicalCustomisationpossible Keen priceOPTIONS AVAILABLE C : Integral certifugal pumps F : Oil-flow controllerH : Heatiny M : Frame on castersT : Programmingclock REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  16. its activities contacts the company CPO 410 OIL CHILLERDESIGN FEATURES Power: 4 kW for oil at 20° CDimensions: 480 x 570 x 830 mmNoise level: 57 dB(A)Voltage: 3 x 400 VoltsTemperature stability: +/- 1° C ADVANTAGESCompactnessStainless steel, sulphur-oil-resistant exchangerEcologicalCustomisationpossible Keen priceOPTIONS AVAILABLE A : Metal air filtersB : Cleanable exchanger for unclean oil C : Integral certifugal pumpsF : Flow controllerH : Heatiny M : Frame on castersT : Programmingclock REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  17. its activities contacts the company CPO 510-610-810 OIL CHILLERS DESIGN FEATURES Power: 5-6 et 8 kW for oil at 20 ° CDimensions: 620 x 650 x 1080 mmNoise level: 58 dB(A) - 250 HzVoltage: 3 x 400 VoltsTemperature stability: +/- 1° C ADVANTAGESCompactnessStainless steel, sulphur-oil-resistant exchangerEcologicalCustomisationpossible Keen priceOPTIONS AVAILABLE A : Metal air filtersB : Cleanable exchanger for unclean oil C : Integral certifugal pumpsF : Flow controllerH : HeatinyM : Frame on castersT : Programmingclock REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  18. its activities contacts the company HIGHER POWER CPO OIL CHILLERS For powers higher than 9 kw, we work to specifications that we evolve with our customer.Often, systems combining a CSW water-refrigerating unit with a water/oil exchanger are more powerful.Questions of size also induce us to find specific solutions to each case.Our metalwork shop guarantees flexibility and an infinite range of possibilities exactly answering the request.Do not hesitate to contact us so that we may together prepare the specifications for your project. REFRIGERATION OIL CHILLERS standard CSO range customised CPO range 1.4 kW 2-3 kW 4 kW 5-8 kW above 9 kW © 2007 marksa

  19. its activities contacts the company EXCHANGER SYSTEMSWhen the customer has a centralised installation, it is often more judicious to use that to cool a machine or a new industrial process.Marksa has a family of exchangers or exchanger systems to precisely meet the customer’s expectations.Plaque, tubular or spiral exchangers, made of stainless steel, copper, copper with aluminium fins, copper with specific coatings for aggressive fluids, etc.Water/water, water/oil exchangers, etc. REFRIGERATION EXCHANGER SYSTEMS © 2007 marksa

  20. its activities contacts the company CUSTOMISED SYSTEMSWe design a specific refrigerating machine on the basis of specifications defined in close co-operation with our customer, in order scrupulously to meet its expectations.Dimensions, power, fluid to be cooled, with or without pump, with or without tank, special colour, piping, etc. REFRIGERATION CUSTOMISED SYSTEMS © 2007 marksa

  21. its activities contacts the company STABILISING SYSTEMSWe have developed a system especially for screw-cutting machines to maintain a vat of oil at the right temperature regardless of the environmental climatic conditions of the premises in which these machines are housed (Too cold an ambient temperature in Winter or too hot in Summer).Our stabilising systems convey water at an adequate temperature to an exchanger immersed in the hydraulic vat. An ideally-placed temperature sensor actuates the heating or cooling function.This discrete, effective, safe and competitive solution increases performances and greatly reduces machine-tool temperature-setting times and mainly those of screw-cutting machines.These systems are easily adaptable to all other machines. REFRIGERATION STABILISING SYSTEMS stabilising advantages Marksa CST © 2007 marksa

  22. its activities contacts the company ADVANTAGES OF THE MARKSA CST STABILISER- Oil is always at an optimum temperature- No time wasted on setting the temperature of the machine- Safe solution (no contact between the radiator and the oil)- Less frequent oil replacement - Less influence of oil on the heating of the machine room - Possibility of machining special alloys (titanium)- Solution which does not require oil filtration (despite the presence of many turnings)- Possibility of integrating this solution into a global cooling system (spindle, electrical equipment box, machine shop)- Timer control possible as optional - Air-conditioning of the premises not judicious REFRIGERATION STABILISING SYSTEMS stabilising advantages Marksa CST © 2007 marksa

  23. its activities contacts the company MANAGEMENTF. JOLLY / +41 (0)32 933 56 07 / COMPRESSED AIR / VACUUMJ-P. DIDIER / +41 (0)32 933 56 02 / REFRIGERATION /VENTILATION /AIR-CONDITIONINGF. JUNG / +41 (0)32 933 56 11 / R&D / DESIGN OFFICEA. JEANDEY / +41 (0)32 933 56 05 / METALWORKP. CABEZA / +41 (0)32 933 56 06 / AFTER-SALES SERVICET +41 (0)32 933 55 55 / F +41 (0)32 931 15 65 / fjo@dixi.ch jpd@dixi.ch fju@dixi.ch aje@dixi.ch pcz@dixi.ch marksa@dixi.ch © 2007 marksa

  24. its activities contacts the company 1935FOUNDATION OF MARKSA SASpecialising in compressed air 1960PURCHASE OF MARKSA BY DIXISpecialising in compressed air & industrial cooling1980DEVELOPMENT OF HEAT PUMPS1990INCLUSION OF THE BUILDING INDUSTRYAir-conditioning & Ventilation1992CREATION OF THE INDUSTRIAL METALWORK SHOP2003CREATION OF A VACUUM TECHNIQUES DEPARTMENT2004SPECIALISATION IN INDUSTRIAL VENTILATIONOil mists, polishing… HISTORY GEOGRAPHICALLOCATION © 2007 marksa

  25. its activities contacts the company HISTORY GEOGRAPHICALLOCATION MARKSA39 av. du TechnicumCH - 2400 Le LocleT +41 (0) 32 933 55 55F +41 (0) 32 931 15 65 marksa@dixi.ch www.marksa.ch © 2007 marksa

  26. its activities contacts the company A WORLDATYOUR SERVICEThe sound reputation of Marksa has grown over several decades thanks to the quality of our after-sales service.Whatever the activity suggested, Refrigeration, Air-conditioning, Ventilation, Compressed Air or Vacuum Technology, we offer the identical services.SPEED / EFFICIENCY / COMPETITIVENESSWe are able to check, overhaul, maintain and obviously repair both Marksa installations and our competitors’ equipment.Our after-sales service vehicles are equipped with all the everyday materials and tools necessary for fast repair with no need for a second visit.Our technicians are extremely skilled in their respective areas of activity. They regularly follow courses so that they are always completely technically up-to-date.The human qualities and professional approach of our staff make for a constructive dialogue and relationship with our customers.This relationship is the basis of the confidence necessary for a durable association. AFTER-SALES SERVICE © 2007 marksa