270 likes | 295 Views
Chauvin Arnoux Group, an industrial leader, offers energy metering, measuring instruments, and energy intelligence solutions. Discover network supervision, energy management tools, and advanced measurement equipment.
E N D
An international industrial group A leader in measurement Chauvin Arnoux Group & Chauvin ArnouxEnergy
The Chauvin Arnoux group Chauvin Arnoux in a few figures Sales approximately 100 million euros Founded in 1893 1,000 employees 55% of sales abroad A strongpresence at home in France and internationallythrough 10 subsidiaries, a sales network, and distributorpartners
The Chauvin Arnoux group 5French companies sustaining the product offer Manumesure Metrology & regulation tests, measure services Chauvin Arnoux Portable Testing & Measuring instruments • Chauvin Arnoux Energy • Energy metering, measuring, and monitoring equipment Pyrocontrole Temperature in industrial processes
Metering, measuring,& energy performance Energy intelligence expert Chauvin Arnoux Energy
Export sales • 4 Export sales zones: Europe, Africa, Asia - Middle East, and Americas – Caribbean • 10 Chauvin Arnoux group subsidiaries • A worldwide network of partners 70 employees, 20 of them R&D engineers Sales: €16 million (2017)
What Chauvin Arnoux Energy offers Network supervision Measurement and instrumentation Energy management Auxiliary relays • Energy monitoring and tracking software • LV Submeters • Power Monitoring Devices • Physical measurement sensors • Current transformers • Measurement shunts • Analog indicators • Digital indicators • Hour meters • Measurement & process converters • “Paperless“ recorders • Other measurement products • Power Quality analyzers • Measurement converters • Power Monitoring Devices • Tariff meters • Transformers for tariff meters • Instantaneous relays • Time-lag relays • Function relays • Receptacles and accessories
Energy management ULYS and MEMO electric submeters Complete metering plan implementation TTA(MID) TD80 TDA80(MID) MD32 MD65 MD80(MID) Three-phase network - LV Single-phase network - LV • Optimized feeder rating: 32A / 45A / 65A / 80A or CT 1/5A • Energy rebilling applications: MID certification • Multi-protocol communication management: Modbus, M-bus, and Ethernet • A compact and versatile metering solution
Energy management ULYS/MEMO Innovative functions and solutions T1/T2 Reset V-U-I-F-PF FTP PUSH
Energy management Power monitoring device for power grids The ENERIUM line • Supervision of LV/MV/HV networks • Network analysis per EN 50160 • High accuracy metering
Energy management ENERIUM
ENERIUM : Energy contract tuning • Abidjan harbour in Ivory Coast • The second most important harbour of Africa is equipped with more than 300 Ulys energy meters and Enerium PMDs. This fleet of equipment provides load curves and energy consumption data used to rebill the private companies working in the harbour.
Energy management ELOG DATA LOGGER 4 EXPORT RECORD CALCULATE COLLECT 3 2 1
Energy management Energy Information System Software MONITORING SUPERVISE DASHBOARD TOOLS OF ANALYSES ALARMS ENERGY MODELS. CALCULATIONS VIRTUAL METERS SHARE REPORTING CONSOLIDATE CONTROL THE DATA ARCHIVE EXCHANGE THE DATA
Energy management Metering and measuring equipment, Data Logger Billing meters PMD Submeters ConcentratorsData collectors PLCs Energy & Utilities Water Physical parameters Electricity Gas Climate parameters Heat Cold
Network supervision MAP network quality analyzers • Line of fixed and portable analyzers • Guarantor of electric power supply quality: • Class A per standard IEC 61000-4-30 • Check of compliance with standard EN 50160 • Maintenance of the installation via 24/7 recording: • Electrical quantities (V/U/I/P/Q/S) and energies • Harmonic phenomena/Flicker/Unbalance, etc. • Power quality events diagnostic: • Detects sag, interruptions… and transients up to 2 Mhz • RMS waveform/associated cycle
Network supervision LV current measurement transformers for tariff metering JVR – JVO – J3R – JVP – TRI500 – TRI700 JVO JVP TRI 500 TRI 700 JVR J3R • CLOSED CORE • Wound / Cable / Busbar primary • Class: 0.5 or 0.2 s • Ratio: single or multiple ratings • Current: 5 to 3,000 A / 5 A • Power: 7.5 to 30 VA • Cable: Ø 42 to 90 mm • Busbar: 50*50 to 100*40 mm • THREE-PHASE PLATE • Class: 0.5 or 0.2 s • Ratio: single or multiple ratings • Current: 50 to 600 A / 5 A • Power: 3.75 to 15 VA Compliant with IEC 60044-1 Products approved by ERDF
Network supervision Programmable analog & digital Transducer TRIAD 2, T82, CA 3420 TRIAD 2 T82 • AC quantities • Class: 0.1 • Short response time • 1,2,3,4 analog outputs • RS485 or Ethernet digital outputs • Configurable via TRIADJUST2 • Compliant with IEC 60688IEC 61000-6-5 • DC, physical, AC quantities • Class: 0.5 • 1 analog output • Factory-configured • For nuclear applications
IEC 61850 network communication gateway ELINK 61850 Communication: IEC 61850 – Edition 2 server Modbus RS485 Master TRIAD 2 and ENERIUM seen as IEC 61850 native products Easyimplementation via web pages High performance: up to 20 slave devices ABB Turkey and Czech Republic Substations ENERIUM + TRIAD 2 beingqualified to ABB Communication withIEC 61850 Protection relays
Measurement and Instrumentation Programmable digital and analogindicators CA 2150 µDIGI2 µDIGI1 FOR SEVERE ENVIRONMENTS • Formats: 48x48, 72x72, 96x96, 144x144 • Deflection: 90°, 250° • Functions : Current, voltage, powers, cos phi, frequency, process signals (4-20 mA), synchronization, command function, hour meters • Custom products • Line approved for nuclear, marine, and rail applications 5-DIGIT DISPLAY • Format: 48x96mm • Multi-function Viewing and programming software • Options: RS232, RS485, relay, or analog output Simplified programming, quick connection, attached without tools
Auxiliary relays For severe and critical environments • Types of relay • Instantaneous • Bistable • High-speed • Time-lag • Functions (Blinker, Passage, Stepping) • Multi-contact • Main applications: • Energy, Nuclear markets (power stations, MV switchgear, HV/MV stations) Products K3-qualified. • Rail (rail substations, rolling stock) Products compliant with railway standards EN 50205, EN 61373, EN 45545, etc.
2018 – Cairo city metro system • Where: • Cairo City – Partner : Mortagycon • Who: • Metro Cairo City • Service: • Maintenance Department • Products : • Relays • Process: • Submitting – Testing – Presentation • Results : • Granted in March 2018 : 260K€ order • 2100 FOKB relays
Applications Proposition of a very broad product and service offering meeting all its customers’ needs.
Support & Services • International technical support • Specifications of products & solutions • Commissioning and verification of installations • Training, on site or on line, with accreditation • Maintenance contract
Chauvin Arnoux Energy Thank you for your attention