1 / 21

Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001

Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001. Outline of talk. VPT Operation Supercrystal layout Test facilities at RAL and Brunel Characterisation results:  Angle scan  B-field response  Gain  Photocathode sensitivity

Download Presentation

Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 1

  2. Outline of talk • VPT Operation • Supercrystal layout • Test facilities at RAL and Brunel • Characterisation results: •  Angle scan •  B-field response •  Gain •  Photocathode sensitivity •  Radiation hardness •  Photocathode uniformity • Technical specification • Summary CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 2

  3. =26.5 mm MESH ANODE Photodetectors: end caps • B-field orientation favourable for VPTs • (Axes: 8.5o < || < 25.5o wrt to field) • More radiation hard than Si diodes • (with UV glass window) • Gain 8 -10 at B = 4 T • Active area of ~ 280 mm2/crystal • Q.E. ~ 20% at 420 nm Vacuum Phototriode (VPT): Single stage photomultiplier tube with fine metal gridanode Selected supplier: RIE (St Petersburg) CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 3

  4. VPT Gain vs Dynode Voltage CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 4

  5. VACUUM PHOTOTRIODE HV FILTERING ELECTRONICS CRYSTAL ‘Supercrystal’ Layout ‘Supercrystal’: carbon-fibre alveola containing 5x5 tapered crystals + VPTs + passive HV filter (138 Identical Supercrystals per Dee) Signals fed via 600 mm cable to Preamplifier + Front End electronics behind Dee Backplate CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 5

  6. Characterisation of VPTs Detail of RAL test Cell 4.0T Solenoid at Brunel 1.8T Dipole Magnet at RAL All VPTs are measured at 0  B  1.8T and -30o 30o at RAL Sample VPTs are measured at B =4.0T and  = 15o at Brunel Perspex diffuser plate with LEDs at corners. (Red circle indicates effective VPT diameter) 500 ‘Preproduction’ VPTs delivered by RIE in autumn 2000 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 6

  7. Response vs Angle at B=1.8T Arrows indicate angular regions of end caps CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 7

  8. 0.80 0.85 0.90 0.95 1.00 1.05 1.10 Response vs B-Field Strength VPT Axis at 15o w.r.t. Magnetic Field CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 8

  9. 6 8 10 12 14 16 18 20 16 18 20 22 24 26 28 30 (%) Distributions of Gain (B=0) and Quantum Efficiency Taken from the ‘passport’ supplied with each tube by the manufacturer Gain and quantum efficiency are uncorrelated CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 9

  10. 0 10 20 30 40 50 60 70 80 90 100 Anode Response Distribution B=1.8T =15o Spread in anode response  Some sorting of VPTs necessary CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 10

  11. Test beam:Energy Resolution No preshower detector With preshower detector CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 11

  12. Faceplate optical transmission Post-irradiation Loss in optical transmission of 2 faceplate samples after 25 kGy 60Co irradiation (380Gy/hour) (approx 10 yrs LHC at  = 2.6) CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 12

  13. VPT Behaviour Under Irradiation 60Co Irradiation (58 Gy/hr) Photocurrent produced by Cerenkov light in VPT window. (Vertical lines correspond to pauses in irradiation) VA=1000 VD= 800 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 13

  14. Photocathode Uniformity VPT operated as a diode Blue LED ( = 430 nm, 0.5mm spot) CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 14

  15. Cathode uniformity - VPT 137 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 15

  16. Cathode uniformity - VPT 354 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 16

  17. e- beam vs LED measurement CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 17

  18. B-field sensitivity (H2 vs RAL) Relative response of prototype 1” VPTs: RAL B=1.8T vs H2 B=3.0T Relative response, B=3.0T/B=0T, H2 CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 18

  19. Technical Specification for Pre-production VPTs CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 19

  20. Technical Specification for Production VPTs Burn-in less severe (4hrs @ 100nA vs 10hrs @ 200nA), Burn-in ratio tightened from 0.8 t0 0.9 Lower limit on P and G reduced, but previously defined before burn-in Lower limit on product PxG effectively increased There is now an upper limit on PxG to limit spread in anode response Sample faceplates must transmit 90% of PWO light after 20kGy and 5x1014 fast n cm-2 Require complete absence of internal discharge at 1000V, at 0T and 1T  B  4T CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 20

  21. Summary • A new generation of fine-mesh VPTs has been developed to satisfy the high magnetic field/radiation hardness requirements of CMS • An automated characterisation facility has been commissioned to handle 15000 devices • The performance of 500 pre-production VPTs from RIE meets CMS requirements • Some sorting by anode sensitivity will be necessary • The technical specification has been revised • The full production order for 15000 devices is about to be placed CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 21