An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MUR- Pre Monitoring Walk-down Findings (cont.)

  2. MUR- Pre Monitoring Walk-down Findings (cont.)

  3. MUR- Pre Monitoring Walk-down Findings (cont.)

  4. MUR- Power Ascension • MUR Power Ascension Occurred in 3 Steps of .5% RX Power Increase. • After each Step a soak time of 1 hour was put in place for MUR Team to perform Post MUR walk-down. • Unit 2 MUR was performed on 10/4/2010 • Unit 1 MUR was performed on 10/13/2010.

  5. MUR- Power Ascension • Unit 2 MUR post walk-downs did not identify any significant issues and was successfully completed. • Unit 1 MUR post walk-downs during the three power ascension identified a change in the 11 FWP discharge line movement.

  6. MUR- 11 FWP Movement Issue • Prior to MUR, 11 FWP discharge pipe had movement of approximately 3/16 inches. • NRC questioned (2/25/2010) this pipe interference with this pipe movement with concern of support bolt impacting FW pipe causing damage. • Due to the thickness of the FW Pipe insulation (2”) with the minimal pipe movement, there was enough clearance to keep pipe from interface with hanger bolt.

  7. MUR- 11 FWP Movement Issue (cont.)

  8. MUR- 11 FWP Movement Issue (Cont.) • During Unit 1 MUR 1st Power Ascension, 11 FWP pipe movement changed. • Pipe movement ceased for a while and began to move in the same magnitude and frequency as identified during pre MUR walk-down. • During second power accession, the pipe remained with the same cycle of stopping and moving. The magnitude increased slightly. • During final power accession, the pipe swaying decreased to less than pre MUR accession.

  9. MUR- Final Results • Successful Completion of Unit 1 and Unit 2 MUR with an additional 8 MWe per Unit. • Regulatory Margin was maintained with NRC during the two MUR evolutions.

  10. Question/Comments