240 likes | 473 Views
ENE 428 Microwave Engineering . Lecture 6 Transmission lines problems and microstrip lines. RS. Review . Input impedance for finite length line Quarter wavelength line Half wavelength line Smith chart A graphical tool to solve transmission line problems
E N D
ENE 428Microwave Engineering Lecture 6 Transmission lines problems and microstrip lines RS
Review • Input impedance for finite length line • Quarter wavelength line • Half wavelength line • Smith chart • A graphical tool to solve transmission line problems • Use for measuring reflection coefficient, VSWR, input impedance, load impedance, the locations of Vmax and Vmin
Ex1ZL = 25+j50 , given Z0 = 50 and the line length is 60 cm, the wavelength is 2 m, find Zin.Ex2 A 0.334 long TL with Z0 = 50 is terminated in a load ZL = 100-j100 . Use the Smith chart to find a) Lb) VSWRc) Zind) the distance from load to the first voltage minimum
Ex3ZL = 80-j100 is located at z = 0 on a lossless50 line, given the signal wavelength = 2 m, find a) If the line is 0.8 m in length, find Zin. b) VSWR c) What is the distance from load to the nearest voltage maximum d) what is the distance from the input to the nearest point at which the remainder of the line could be replaced by a pure resistance?
Ex4 A 0.269- long lossless line with Z0 = 50 is terminated in a load ZL = 60+j40 . Use the Smith chart to find a) L b) VSWR c) Zin d) the distance from the load to the first voltage maximum
Impedance matching • To minimize power reflection from load • Zin = Z0 • Matching techniques 1. Quarter - wave transformers for real load 2. single - stub tuners 3. lumped – element tuners • The capability of tuning is desired by having variable reactive elements or stub length.
Simple matching by adding reactive elements (1) EX5, a load 10-j25 is terminated in a 50 line. In order for 100% of power to reach a load, Zin must match with Z0, that means Zin = Z0 = 50 . • Distance d WTG = (0.5-0.424) +0.189 = 0.265 to point 1+ j2.3. Therefore cut TL and insert a reactive element that has a normalized reactance of -j2.3. • The normalized input impedance becomes 1+ j2.3 - j2.3 = 1 which corresponds to the center or the Smith chart.
Simple matching by adding reactive elements (2) • The value of capacitance can be evaluated by known frequency, for example, 1 GHz is given.
Single stub tuners • Working with admittance (Y) since it is more convenient to add shunt elements than series elements • Stub tuning is the method to add purely reactive elements • Where is the location of y on Smith chart? We can easily find the admittance on the Smith chart by moving 180 from the location of z. Ex6 let z = 2+j2, what is the admittance?
Stub tuners on Y-chart (Admittance chart) (1) • There are two types of stub tuners • Shorted end, y = (the rightmost of the Y chart) • opened end, y = 0 (the leftmost of the Y chart) Short-circuited shunt stub Open-circuited shunt stub
Stub tuners on Y-chart (Admittance chart) (2) • Procedure • Locate zL and then yL. FromyL, move clockwise to 1 jb circle, at which point the admittance yd = 1 jb. On the WTG scale, this represents length d. 2. For a short-circuited shunt stub, locate the short end at 0.250 then move to jb, the length of stub is then l and then yl = jb. 3. For an open-circuit shunt stub, locate the open end at 0, then move to jb. 4. Total normalized admittance ytot = yd+yl = 1.
Microstrip (1) • The most popular transmission line since it can be fabricated using printed circuit techniques and it is convenient to connect lumped elements and transistor devices. • By definition, it is a transmission line that consists of a strip conductor and a grounded plane separated by a dielectric medium
Microstrip (2) • The EM field is not contained entirely in dielectric so it is not pure TEM mode but a quasi-TEM modethat is valid at lower microwave frequency. • The effective relative dielectric constant of the microstrip is related to the relative dielectric constant r of the dielectric and also takes into account the effect of the external EM field. Field lines where the air and dielectric have been replaced by a medium of effective relative permittivity, eff Typical electric field lines
Microstrip (3) Therefore in this case and
Evaluation of the microstrip configuration (1) • Consider t/h < 0.005 and assume no dependence of frequency, the ratio of w/h and rare known, we can calculate Z0 as
Evaluation of the microstrip configuration (2) • Assume t is negligible, if Z0and r are known, the ratio w/h can be calculated as The value of r and the dielectric thickness (h) determines the width (w) of the microstrip for a given Z0.
Ex8 A microstrip material with r= 10 and h = 1.016 mm is used to build a TL. Determine the width for the microstrip TL to have a Z0 = 50 . Also determine the wavelength and the effective relative dielectric constant of the microstrip line.
Wavelength in the microstrip line Assume t/h 0.005,
Attenuation • conductor loss • dielectric loss • radiation loss where c= conductor attenuation (Np/m) d= dielectric attenuation (Np/m
Conductor attenuation If the conductor is thin, then the more accurate skin resistance can be shown as