BLINDNESS AND PHYSICS

BLINDNESS AND PHYSICS. W. Kohn J. Klingshirn University of California, Santa Barbara May 31, 2012 UCLA. General Introduction Macular Degeneration causes a patient’s central visual field to be spatially distorted. This project’s goals are to:

soyala
Download Presentation

BLINDNESS AND PHYSICS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BLINDNESS AND PHYSICS W. Kohn J. Klingshirn University of California, Santa Barbara May 31, 2012 UCLA

  2. General Introduction Macular Degeneration causes a patient’s central visual field to be spatially distorted. • This project’s goals are to: • Quantitatively characterize the distortion perceived by the patient. • Develop optical and computer-based methods to compensate for the perceived macular distortions.

  3. The Amsler Grid • Widely used, non-invasive, diagnostic tool • Dimensions: (10 cm)2 • How used: • Presented 35 cm in front of one eye, head in a chin rest. • Eye focused on highlighted central point, C • A person with a healthy eye perceives the Amsler Grid (AG) and its center precisely as shown on the slide. Fig. 2a: A useful diagnostic tool in Ophthalmology. The center is indicated by a highlighted dot.

  4. Amsler Grid as perceived by a Patient • Fig. 2b: The distorted AG as perceived by a typical patient with macular degeneration • Two abnormal features: • Distortions fo AG lines (however peripheral lines are undistorted) • Dark are(s) with diameter ~2-3 cm

  5. Editing / Diagnosis • MD Patient wears his normal reading glasses (if any). • Amsler Grid (AG) is presented to the patient on a computer monitor, 40 cm ahead. • Head is fixed in a chin rest, Patient is asked to focus on the central point C and maintain focus. • The patient uses simple software and the mouse to straighten distorted “vertical” & “horizontal” lines, until he perceives the grid as “perfect”. (Vertical” and “Horizontal” refer to the edges of the grid.) • During the straightening procedure the computer records the displacements of all intersection points of the AG. • The displacements constitute the spatial diagnosis of the distortions. Figure 3: Using the mouse to edit the lines of the Amsler Grid

  6. Interpolation Displacement of Arbitrary Points Inside the Amsler Grid • At the conclusion of the diagnostic/editing procedure the patient perceives the Amsler Grid without distortions. • Typical reading material consists of ~1000 x 1000 = 106 pixels per page. • Straightening out the lines in the reading material with 106 points is comparable to editing 106 AG grid intersection points. • It is unrealistic for the patient to do this point by point. • Instead we obtain the required displacement vectors for other points within the Amsler Square by suitable interpolation. • The 400 (or fewer) displacements supplied by the diagnosis are used to obtain all other points within the AG using a cell phone sized computer.

  7. Correction By Computer • The reading material is scanned, photographed, or converted into an array of pixels. • Computer software displaces each pixel using the displacements obtained from the diagnostic procedure. • The patient views the corrected text at the appropriate distance. It appears undistorted. What the patient sees without the correction What the patient sees with the correction

  8. Dynamic Compensation • It isn’t sufficient to correct the text for a small area of a printed page. The patient needs to read the entire page. • The solution is to apply the compensation dynamically. • A Computer Based Correction Device • Dynamic Compensation • Anti-Distortion applied in real-time by a handheld computer. To the patient, the image will appear undistorted.

  9. Correction by a Refractive Material • Using the results of our diagnostic procedure, an arbitrary, smooth, sufficiently weak, macular distortion can be corrected by a suitably patterned slab of optical material. • The slab would be made from glass or optical quality plastic, with dimensions on the order of 10 x 10 x 4 cm. • The pattern on the top surface and the plate thickness are chosen so as to cancel the distortions created by the patient’s Macular Degeneration. • L = 10 cm • b = 4 cm • The top surface is custom drilled downward for each patient to a maximum depth of b/2.

  10. Contour Lines of a Patterned Upper-Slab Face Z(x,y) = sin(π x / L) * sin (π y/L)

  11. Prototype Optical Slab Created by UCSB Machine Shop A refractive contoured slab for correcting macular distortion. The reader slides it along over horizontal reading material.

  12. Current Status • Analysis of the diagnostic procedure is complete. • It has been successfully tested on patient ‘Eve’. • The initial test of patient ‘Eve' will be followed up by extensive further testing. • A computer program that creates a dynamic spatial correction has been implemented. • Prototype Optical Slabs that provide a compensating correction have been fabricated.