ZOIDDx. Overview. KEP designed the ZOID DC to provide: 1. A convenient way for a machine operator to: a. View machine status and parameters. b. Change applicable machine operation parameters. c. Maintain the running of a machine.
E N D
Overview • KEP designed the ZOID DC to provide: • 1. A convenient way for a machine operator to: a. View machine status and parameters. b. Change applicable machine operation parameters. c. Maintain the running of a machine. • 2. Enhanced capabilities to a machine through: a. Real Time Clock access. b. RS-232 ASCII output. c. Direct keypad interface. d. Visually displayed prompts.
Overview • The ZOID DC is designed to provide these features in a cost effective unit. It interfaces to the machine through a single cable (typically to a PLC programming port). • The ZOID DC is a simple, easy-to-use interface that talks to your PLC directly through the programming port. Additional communications modules and cumbersome interface ladder logic are no longer necessary. Just plug in both ends of the cable and you are ready to go!
Features & Benefits • Meets CE Mark requirements (DC powered units only)Assurance of operation in electrically noisy environments. • 2 x 20 character, VFD or backlit LCD display Provides high visibility of important information in factory conditions. • 24 VDC power(AC power optional) • 12 Programmable function keys (24 with shift keys) Provides flexibility with user defined keys tailored to the application.
Features & Benefits • 487 message capability 32K of user memory space. • Multiple embedded variables per screen More information at your finger tips. • Serial interface for programming setup and printout of messages Gives the ability to print out reports or alarm data to remote devices. • Real time clock and calendar Can be downloaded to give micro PLC’s Time and Date control capabilities. Can also be embedded into messages for Time and Date stamping of alarms.
Applications • Machine operations: a. Message/Alarm display and management. b. Set up station for machine configuration. c. Machine cycles that require operator input. • Process operations: a. Display of production figures. b. Status report generation. c. Process tuning.
Applications • Maintenance operations: a. Display/Monitor machine status. b. Troubleshoot PLC I/O devices. c. Supervisory access to restricted settings.
Temperature: VFD: 32-140°F (0-60°C) LCD: 32-122°F (0-50°C) Power: 12 to 24 VDC, 110 VAC or 220 VAC Battery Life: (for real time clock & memory backup) 10 years calculated Display: VFD Vacuum Fluorescent Display; 2 lines; 20 characters per line; character height is 0.2" LCD Backlit Liquid Crystal Display; 2 lines; 20 characters per line; character height is 0.2" Serial Communication: RS-232 8 bit, no parity, 1 start bit, 1 stop bit, no handshake, 300, 600, 1200, 2400, 4800 or 9600 baud Keypad: Membrane Keypad, dome, positive feedback 1 million keystrokes minimum Keypad Rating: NEMA 4X/IP65 Approvals: CE (ZOID DC only) Dimensions: H = 6", W = 8", D = 1.75" Cutout H = 5.1, W = 7.1 Specifications
Pricing and Availability • All ZOIDDx Models are available from your local KEP distributor. You will find this feature packed unit at a surprisingly affordable price. • Every ZOIDDx is burned in for at least 24 hours and undergoes a full functional test before shipping. • KEP Warranties its ZOIDDx products for 1 year.