1 / 12

How to install a fire sprinkler design system?

Installing a fire sprinkler design system can be a complex task as its installation will require you to have specialized knowledge and compliance with various codes and standards. For fire safety, you should hire a suppression engineer who can provide you with safety advice as per the safety of your building.

Download Presentation

How to install a fire sprinkler design system?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FIRE SPRINKLER FIRE SPRINKLER

  2. A fire sprinkler is a device that automatically finds and puts out fires in buildings. It's a really important part of keeping places safe from fires. The system has pipes filled with water, and each pipe has sprinkler heads. These sprinkler heads are placed in different spots in a building and release water when they sense a certain heat, showing there's a fire.

  3. SYSTEMS WORK SYSTEMS WORK

  4. Fire sprinkler design systems work based on the principle of heat detection. These systems are designed to detect and control fires at their early stages, preventing the spread of flames and reducing the potential for extensive damage.

  5. NETWORK OF PIPES NETWORK OF PIPES The system consists of a network of pipes that are filled with water or another firefighting substance. The pipes are strategically installed throughout the building, especially in areas prone to fire risks. SPRINKLER HEADS SPRINKLER HEADS Sprinkler heads are mounted on the pipes and are equipped with heat-sensitive elements. These elements are usually made of a glass bulb or a metal alloy that melts or breaks at a specific temperature. CLOSED SYSTEM CLOSED SYSTEM Under normal conditions, the system remains closed, with water or the firefighting agent contained within the pipes. This ensures that water doesn't flow unless there's a fire.

  6. HEAT ACTIVATION HEAT ACTIVATION When a fire occurs, the heat generated causes the temperature-sensitive element in one or more sprinkler heads to reach its activation point. The element then breaks or melts, allowing the water to flow. INDIVIDUAL ACTIVATION INDIVIDUAL ACTIVATION Importantly, not all sprinkler heads activate simultaneously. Only the heads directly exposed to the elevated temperature will activate, which helps minimize water damage and ensures that water is directed specifically to the area affected by the fire. WATER DISCHARGE WATER DISCHARGE Once activated, the sprinkler head releases water in a controlled manner. The water is distributed over the fire, suppressing it by cooling the surrounding area and removing heat.

  7. FIRE SPRINKLER FIRE SPRINKLER SYSTEMS SYSTEMS

  8. DESIGN AND PLANNING DESIGN AND PLANNING Engage a qualified fire protection engineer or designer to assess the building's needs and design an appropriate system. Consider the building layout, occupancy type, fire hazards, and local building codes. Determine the type of fire sprinkler design system (wet, dry, pre-action, etc.) based on the specific requirements.

  9. REGULATORY COMPLIANCE REGULATORY COMPLIANCE Ensure compliance with local building codes, fire codes, and any other relevant regulations. Obtain necessary permits from local authorities before starting the installation. WATER SUPPLY WATER SUPPLY Verify the availability and adequacy of the water supply for the sprinkler system. Connect the system to a reliable and pressurized water source, such as a municipal water supply or a dedicated fire pump.

  10. PIPE INSTALLATION PIPE INSTALLATION Install the network of pipes throughout the building according to the approved design. Ensure that pipes are adequately supported and protected against damage. Follow the manufacturer's guidelines for pipe materials and installation methods. SPRINKLER HEAD INSTALLATION SPRINKLER HEAD INSTALLATION Install sprinkler heads at designated locations based on the design. Position sprinkler heads correctly, considering factors like ceiling height and obstructions. Ensure that sprinkler heads are securely attached and properly oriented.

  11. SYSTEM COMPONENTS SYSTEM COMPONENTS Install other system components, such as control valves, check valves, alarm devices, and pressure gauges. Connect the system to any necessary alarms or monitoring devices. TESTING AND INSPECTION TESTING AND INSPECTION Conduct thorough testing of the system to ensure proper functionality. Perform a hydraulic calculation to verify water flow and pressure meet design requirements. Schedule inspections with local authorities to ensure compliance.

  12. THANK YOU