An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ZYOPTIX® Personalized TreatmentAdvanced (PTA) Our best excimer procedure ever

  2. ZYOPTIX Personalized Treatment Advanced (PTA) • PTA - Introduction • PTA - Clinical results • New ZYOPTIX Advanced Nomogram 1.3 • PTA - Summary

  3. ZYOPTIX Personalized TreatmentAdvanced (PTA) Introduction

  4. PTA - Introduction • PTA is an Aspheric Wavefront Treatment which combines ZYOPTIX Aspheric & ZYOPTIX Personalized • Treatment of preop higher & lower aberrations • Compensation of surgically induced spherical aberrations • Extended Advanced Nomogram across all treatment ranges • With 100Hz & ACE eyetracker technology The ultimate procedure

  5. PT PT PTA PTA - Introduction • PTA is the complete procedure for lower & higher order aberrations without induction of spherical aberration Plano / TS TS also for hypermetropia Myopia, hypermetropia, astigmatism Aspheric Myopia, hypermetropia, astigmatism Myopia only

  6. PTA - Introduction • The evolution of the ZYOPTIX algorithms

  7. PTA - Introduction The best quality of vision available today!

  8. PTA - Introduction • Ease of use - no changes of laser or diagnostic required Personalized Advanced ZYOPTIX Card Next generation Treatment Calculator V 1.3

  9. PTA - Introduction • How does PTA work? Input Algorithm Result Wavefront: Lower & Higher Order Zernike Terms Preop aberration compensation Optical Zone Procedure File Surgery induced aberration comp. Manifest Refraction Advanced Nomogram Base Nomogram

  10. PTA -Introduction • Goals of Personalized Advanced algorithm • PTA integrates knowledge gained in ZYOPTIX Personalized (PT) and ZYOPTIX Aspheric procedures • Optimal postoperative visual performance • Compensates surgically-induced aberrations, especially spherical aberration • Unmatched predictability thanks to the Advanced Nomogram  Now also available for custom hyperopia!

  11. PTA - Introduction • The ultimate algorithm • PTA provides the best visual outcomes thanks to enhanced performance and safety using state-of-art technologies: • Iris recognition for enhanced safety • ACE technology for unsurpassed precision and accuracy • ZYOPTIX Advanced Nomogram for enhanced predictability (now available for customized hyperopia procedures!)

  12. ZYOPTIX Personalized TreatmentAdvanced (PTA) Clinical results – interim analysis !

  13. PTA - Clinical results • Multi-center trial started in March 09 • Asia Eye Institute, Philippines (Dr. Robert T. Ang) • Rutnin Eye Hospital, Thailand (Dr. Noparat Sujaritchan) • Hong Kong Sanatorium and Hospital, Hong Kong (Dr. John S.M Chang Jr) • Contralateral Study of PTA vs PT, both using Advanced Nomogram • Evaluate the safety and effectiveness of the ZYOPTIX Personalized Advanced treatment vs ZYOPTIX Personalized Treatment Algorithm

  14. PTA- Clinical results • Refractive status pre-op

  15. PTA- Clinical results • Refractive status post-op

  16. PTA- Clinical results 1 Day n = 51 1 Week n = 51 1 Month n = 50 • Stability (MRSE over time)

  17. PTA- Clinical results • PTA Predictability (MRSE deviation from target) * B&L study 2008, Dr. Chan, Dr. Ang, Dr. Chang, Dr. Lee, Dr. Wee  Advanced Nomogram enhances predictability

  18. PTA - Clinical results 1 Day n = 51 1 Week n = 51 1 Month n = 50 • Safety

  19. PTA - Clinical results 1 Day n = 51 1 Week n = 51 1 Month n = 50 • Efficacy

  20. N = 50 PTA - Clinical results N = 50

  21. PTA - Clinical results

  22. N = 50 PTA - Clinical results

  23. Cumulative Low Contrast BCVA at 1 Month Post Op 120.0% 100.0% 100.0% 100.0% 84.0% 80.0% % of eyes 60.0% 40.0% 26.0% 20.0% 20.0% 6.0% 4.0% 0.0% 20/16 20/20 20/25 20/40 PTA PT PTA - Clinical results N = 50 N = 50

  24. Analysis diameter at 6mm N = 50 PTA - Clinical results • Q values analysis PTA helps to preserve the natural prolate shape of the cornea!

  25. PTA - Clinical results • Induced Spherical aberration analysis No induction of spherical aberration!

  26. PTA - Clinical results • Surgeon’s feedback • “With the advanced nomogram, the predictability of PTA gets much better” • “The PTA treatment calculator is easy to use” • “Some of my patients reported to be happier with the eye treated with PTA”

  27. ZYOPTIX Personalized TreatmentAdvanced (PTA) New ZYOPTIX Treatment Calculator 1.3

  28. ZYOPTIX Treatment Calculator 1.3 • New features • Faster loading of ote & ate files • Advanced Nomogram is integrated & automatically executed – better ease of use (all Rx range, > 5.0mm wavefront, target Rx, shown in printout) • Improvements for ZYOPTIX Tissue Saving & Aspheric • Display of residual stroma thickness • Optical zone independent from wavefront size • Treatment axis adjustable • No wavefront ate file required for calculation • Support for bilateral calculations • Remove Pachymetry Bug

  29. ZYOPTIX Treatment Calculator 1.3

  30. ZYOPTIX Personalized TreatmentAdvanced (PTA) Summary

  31. PTA- Summary • PTA is the ultimate procedure for patients • PTA provides the best quality of vision • PTA reduces the surgically-induced spherical aberration • PTA minimizes the change of Q values • PTA’s predictability is further improved with the Advanced Nomogram (now also available for hyperopia)