1 / 12

SNAP Electrical Design Estimates

Super Nova/Acceleration Probe. SNAP Electrical Design Estimates. November 16 , 2001 C. Paul Earle. SNAP Functional Block Diagram. Thermal Control & Monitoring. Bright Object Detector. Shutter Control. FPA. S/C C&DH. FPE. ICE. 1553 I/F. Scene. Readout Control Logic.

stevenlogan
Download Presentation

SNAP Electrical Design Estimates

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Super Nova/Acceleration Probe SNAPElectrical Design Estimates November 16, 2001 C. Paul Earle Electrical

  2. SNAP Functional Block Diagram Thermal Control & Monitoring Bright Object Detector Shutter Control FPA S/C C&DH FPE ICE 1553 I/F Scene Readout Control Logic Instrument Control Electronics Science Data I/F Mass Storage (S/C) Data Buffering A/D CDS Detectors Filters Shutter Door Spectrograph DC-DC Converter A/D Focus Control S/C Power Door open / close Figure 1. Electrical

  3. Science Data Rate FPA Size: 144 CCDs @ 1.6Kx1.6K each ~ 368.6 Mpix 44 HgCdTe @ 2Kx2K each ~ 176 Mpix Spectrograph: 1Kx1K ~ 1Mpix Average Data Rate: ==> 545 Mpix for each 200Sec exposure ==> Data rate (avg) ~ (545Mpix/220Sec) ~ 2.5Mpix/s ~ 40 Mbps @16-bits/pix ~ 20 Mbps (with 2:1 loss-less compression) 220Sec 200Sec integration 20Ssec readout Electrical

  4. Focal Plane Electronics CCD Readout ASIC (3” x 3”) each • 4 A/Ds • 4 CDS chips (Correlated Double Sampling) • Bias & Power Generation • Sequencer & Clock Drivers • 188 Readout ASICs • ~ 10 boards (12” x 12”) • 18 ASICs each, 9 ASICs per side • 2 boxes ~ (13.5”x13.5”x6”) each ~ 9lbs each • Total Power: 156Watt (peak), 22 Watt (avg.) Electrical

  5. Thermal Control Requirements: - 70 zones, controlled within +0.5 deg. C of set point - 1 Heater and 1 Temperature Sensor per zone - Each CCD controlled within +0.1 deg. C of set point - Unregulated Heater Power (120Watts) V+ V+ V+ Heater Sensor (AD590) i (T) (1 of 258) Current TLM Figure 2. Electrical

  6. CCD Temperatures Housekeeping Data (1 of 11) A/D Conv. AD 1672 H/K FIFO Mux 16-ch AD506 V- To Memory + CCD temps (188) - V- Zone Temperatures & Other Telemetry points (1 of 5) Mux 16-ch AD506 A/D Conv. AD 1672 H/K FIFO Power Temp ... . . . To Memory Figure 3. Electrical

  7. Readout Data Buffering (1 of 188) (1 of 188) Digital MUX (4:1) FIFO Buffer CCD I/F 4 1 To Storage FPE I/F Capture& Control Logic FPGA (1 of 1) Processor Card I/F Figure 4. Electrical

  8. - - + + On/Off Cmd Driver Amp From PLD Controller Door Actuator HK Mux Actuator Current Temp Sensor Actuator Voltage + To Central HK - I+ Sensor Amp Mechanism Control (Door Control Electronics) Figure 6. Electrical

  9. Processor & Memory Board Startup ROM xfmr xcvr 1553 I/F CPU UTMC 69R000 xfmr xcvr xfmr 1553 I/F xfmr RAM (Data Processing) EEPROM Memory (Data Processing) Ethernet I/F S/W Dev. Figure 5. Electrical

  10. I+ I+ Power Distribution DC/DC Converters +15 V +28 VDC +5 V Current Sense + - Voltage Sense + - Figure 7. Electrical

  11. Board Estimates 10 in Mech Control (6W) Data Buffer (3W) Thermal Control (4W) Housekeeping (16W) Data Buffer (3W) Thermal Control (4W) Processor (4W) Data Buffer (3W) Thermal Control (4W) 9 in FPE Power (9.4W) Main Power (20W) Figure 8. Electrical

  12. Main Electronics Box Summary 10 in Estimated Mass ~ 44 lbs Estimated Power ~ 76 Watts (avg.) Estimated Size ~ (19 x 11 x 10) in. 11 in 19 in Figure 9. Electrical