Analog Discovery Design Kit Mini Course Webinar lecture #2 of 4

Analog Discovery Design Kit Mini Course Webinar lecture #2 of 4. Alan Rux Electrical and Computer Engineering Department University of Massachusetts Lowell Campus. Lecture # 2 Two Channel Oscilloscope & Arbitrary Waveform Generator . Learning the ADK Leads (Analog Discovery Kit)

stuart
Download Presentation

Analog Discovery Design Kit Mini Course Webinar lecture #2 of 4

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Analog Discovery Design KitMini Course Webinarlecture #2 of 4 Alan Rux Electrical and Computer Engineering Department University of Massachusetts Lowell Campus

  2. Lecture # 2Two Channel Oscilloscope & Arbitrary Waveform Generator • Learning the ADK Leads (Analog Discovery Kit) • Oscilloscope Operation • F.F.T. Function

  3. Leads are color coded

  4. Leads we will be using today

  5. You are now connected

  6. To enable the oscilloscope click on the “Scope - in” icon

  7. 2 Channel Oscilloscope Window

  8. 2 Channel OscilloscopeMain Toolbar & Menu-Strip

  9. 2 Channel OscilloscopeMain Toolbar & Menu-Strip

  10. 2 Channel OscilloscopeMain Toolbar & Menu-Strip

  11. 2 Channel OscilloscopeMain Toolbar & Menu-Strip

  12. 2 Channel OscilloscopeMain Toolbar & Menu-Strip

  13. 2 Channel Oscilloscope Main Toolbar Persistence Add XY Histogram Audio FFT Data Measure Current Audio Digital Events Zoom Options Help

  14. Channel Toolbar Channel 1 & 2 Configuration(Vertical Gain, volts/cm )

  15. Channel Toolbar Channel 1 & 2 Configuration(Vertical Gain, volts/cm ) Vertical Range 5V/div to 500uV/div In 1-2-5 steps

  16. ChannelToolbar Channel 1 & 2 Configuration(Vertical Offset, volts/cm ) Offset Range +25V/div to -25V/div In 1-2-5 steps +/-100 mv., min. offset

  17. Channel Toolbar Channel 1 & 2 Configuration(Horizontal Sweep, time/cm )

  18. Channel Toolbar Channel 1 & 2 Configuration(Horizontal Sweep, time/cm ) Time Base 1hr./div to 10ns/div In 1-2-5 steps

  19. Channel Toolbar Channel 1 & 2 Configuration(Trigger Position, time/cm ) Trigger Position +10hr./div to -10hr/div +/-5 usec., min. delay

  20. Channel Toolbar Channel 1 & 2 Configuration(Trigger Configuration)

  21. Trigger Mode: Normal – triggered on specified condition Auto – triggered on trigger condition, self starts in 2 seconds None – the acquisition is started without a trigger Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  22. Source: Channel 1 Channel 2 Digital AWG – 1 AWG – 2 Analyzer Patterns External – 1 External - 2 Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  23. Type of Trigger: Simple – is an edge trigger where the filter, hysteresis, and holdoff parameters are configured automatically. Level is set to 10% of the selected trigger channel range Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  24. Type of Trigger: Edge + slope-condition control Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  25. Type of Trigger: Pulse, will trigger if pulse has a smaller/larger length than the one set by the user. Channel Toolbar Channel 1 & 2 (Trigger Configuration) Set for Less then 200 usec.

  26. Type of Trigger: Pulse, will trigger if pulse has a smaller/larger length than the one set by the user. Channel Toolbar Channel 1 & 2 (Trigger Configuration) Set for more then 200 usec.

  27. Type of Trigger: Transition - the transition time of a signal as compared with a specified length Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  28. Type of Trigger: Transition - the transition time of a signal as compared with a specified length Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  29. Trigger Hysteresis – low and high leveles are determined to avoid bouncing caused by signal noise and also to specify the transition trigger conditions, 20 volts to 1mv and zero volts in 1 -2 -5 steps Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  30. Trigger Hysteresis Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  31. Trigger Holdoff –a adjustable time period during which the oscilloscope will not trigger . this is useful when triggering on complex waveform shapes, so the oscilloscope triggers only on the first eligible trigger point. Time range from 1 hour to 100nsec., in 1 – 2 – 5 steps and zero sec. Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  32. Channel Toolbar Channel 1 & 2 (Trigger Configuration)

  33. Options: General, Display, Colors, Configuration Channel Toolbar Channel 1 & 2 (Options Configuration)

  34. Channel Toolbar Channel 1 & 2 (Color Configuration)

  35. Channel Toolbar Channel 1 & 2 (Color Configuration)

  36. Main Toolbar F. F. T. function FFT View – plots amplitude against frequency, it shows the signals in the frequency domain as opposed to the time domain

  37. 2 Channel OscilloscopeMain Toolbar – FFT function

  38. Arbitrary Waveform Generator • the ADK Leads (Analog Discovery Kit) • Function Generator operation • Oscilloscope use

  39. Leads are color coded

  40. Leads we will be using today

  41. Leads we will be using today Waveform Gen-1 (yellow) to Scope ch-1 (orange) Waveform Gen-1 common gnd. (black) to Scope ch-1 neg. (orange/white)

  42. Analog Discovery BNC Adapter Board Allows the use of standard BNC-terminated test leads & probes on your Analog Discovery Selectable AC and DC coupling to oscilloscope probes Selectable 50-ohm or 0-ohm output impedance on Arbitrary Waveform Generator (AWG) channels

  43. You are now connected

  44. To enable the Waveform Gen. click on the “WaveGen - out” icon

  45. Waveform Generator Window1 Channel, AWG-1

  46. also enable the oscilloscope click on the “Scope - in” icon

  47. 2 Channel Oscilloscope Window

  48. Waveform Generator Window AWG-1 & AWG-2

  49. Waveform Gen./Scope Window1 Channel Oscilloscope & AWG-1 AWG scope

  50. AWG main window