An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Use-Case on treatment planning at HIMAC Koichi Murakami KEK 1st Workshop on the Italy-Japan Collaboration on Geant4 Medical Application 8/Mar./04, INFN Genova 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  2. Introduction • Our project was just started and we are not yet familiar with practical use-cases in medical application. • It is important to collect practical use-cases and requirements for medical users. • We had hearing for treatment planning system at HIMAC (NIRS) on last Dec. • with a brief demonstration of the system. • collecting use-cases and documentation • picking up requirements from use-cases 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  3. Basic Flow of Radiation Treatment • Diagnosis • Prescription according to the treatment protocol. • Treatment planning (our scope) • Discussion based on the results of treatment planning • Treatment 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  4. Input/Output of the system • At first, we list up items taking part in the system. • Diagnosis (input) • “Treatment protocol” to be applied • Image data (CT) of a patient • DICOM format • Specification of ROI (Region Of Interest) • Identification of organs • Specification of target (cancer) volume • Parameters of treatment system • beam energy, parameters of beam line (input) • parameters of collimators (range shifter, MLC, Bolus) (i/o) • Discussion based on the results of treatment planning (output) • Dose distribution • DVH (Dose Volume Histogram) 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  5. Image Data (CT) • DICOM format • “Dr. View” is used as visualization tools. • Resolution • 512x512 pixels of 0.7mm2 in xy-plane • 21cm x 15cm (at MLC in HIMAC) • dz=3/5 mm along z-direction, 30cm in total • Correction • position • smoothing • density (removal of artifact) • Conversion from CT-value to density • material is defined as “water”. 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  6. Specification of ROI • ROI (Region Of Interest) • region for scoring DVH • OAR (Organs At Risk) • Tumor (Target) Volume • GTV < CTV < PTV • GTV (Gloss Tumor Volume) • CTV (Clinical Target Volume) • PTV (Planning Target Volume) • TV = PTV + 6mm (HIMAC) • Operation is carried out by doctors. • Marking ROI for each sliced CT image by hand • Automatic identification of organs is possible with commercial tools. 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  7. Parameters of Treatment System • Beam energy • depending on the depth to tumor • Parameters of magnets • making laterally uniform beam area • Wobbler magnet and scatterer thickness • Ridge filter • forming SOBP (Spread Out Bragg Peak) • Range Shifter • adjusting range • Collimators • Ring collimators • MLC (multi leaf collimator) • Bolus • being sculpted for tumor depth • Control protocols of hardware • GPIB • Original format 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  8. Discussion for Treatment • Treatment team has discussion based on the results of treatment planning. • Dose Distribution • Spatial resolution • 2 times larger size of cells than CT image (1.4mmx1.4mm) • same size along z-direction • more fine resolution in other facilities • DVH (Dose Volume Histogram) • Integrated volume having dose more than given over ROI. • DVH in TV vs. DVH in OAR (Organ At Risk) 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  9. Documentation 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  10. Documentation • Making formatted documentation was just started for our situation. • Digging out actors (list of actors) • Breaking down to sub-systems (tentative) • Glossary of terminology • Description of use-cases 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  11. Digging out Actors • List of Actors • Doctors • MRT (Medical Radiation Technologists) as Operators/Planners • This is our (japanese) situation. Situation can be different between countries. • Other concerned participants • Patients • QA of system (design/study/evaluation) 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  12. System Component • Breaking down to sub-systems • This is currently tentative. • Modeling / Visualization • Management of Geometry and Parameters • Dose Calculation • Analysis 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  13. Scope of System Component (1)Modeling / Visualization • I/O of image data • Interface with CT-system and image servers • Visualization of image data • Image processing in medical use • automatic detection of organs • editing CT-values • modeling of human body • production of DRR (Digitally Reconstructed Radiograph) • (Graphical) user interface 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  14. Scope of System Component (2)Management of Geometry and Parameters • I/O and management of geometry and parameters • beam line parameters and (Geant4) geometry • information of patients • converted from CT images to a suitable for planning (e.g. Geant4 geometry) • Calculation and management of parameters of instruments forming exposure area • collimators/filters • interface with CAD/CAM system • (Graphical) user interface 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  15. Scope of System Component (3)Dose Calculation / Analysis • Dose Calculation • Dose calculation engine • non-MC base code • MC code (e.g. Geant4) • Scoring (Tally) package • Analysis • Analysis (histogramming) package • Interface with visualization of result • (Graphical) user interface 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  16. Description of Use-cases • Items in each use-case • Identifier • Goals in Context • Scope • System / Sub-system / Component • as Black Box / White Box • Level • Summary / User-goal / Function (according to abstraction level) • Actors • Pre-condition • Guarantees • Scenario • Extensions • branches for main scinario • alternatives in cases of failure • variations of what to do for main scenario • Technology and Data Variation • variations of how to do for main scenario • Notes 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  17. Documentation of Use-Case • We’ve made documentation for higher level of use-cases. • 1 summary level of use-case and 4 user-goal level of use-cases for sub-systems • Use-Case: Planning radiation treatment • Making treatment plan with treatment planning system. • summary (top) level • scope : radiation treatment planning system • sub-systems are used as black boxes. 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  18. User-goal level of Use-Cases (1) • Input of treatment information • Scope : Visualization / Modeling (White Box) • Processing CT image of a patient and setting information of treatment • Input of exposure condition • Scope: Management of geometry and parameters (WB) • Setting exposure condition of the system • beam line parameters • exposed dose 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  19. User-goal level Use-Cases (2) • Calculation of parameters of instruments • Scope: Management of geometry and parameters (WB) • Calculating parameters of instruments forming exposed area • ridge filter • range shifter • bolus • MLF (Multi Leaf Collimator) • Calculation of Dose Distribution • Scope : Dose Calculation (WB) • Calculating dose distribution in ROI under the given condition 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application

  20. Future Direction • Collecting Use-Cases for as many facility / system of treatment planning system as possible • Documentation of Use-Cases • Breaking down to well-defined sub-systems • Finding components which can be shared between different system. • Picking up requirements 1st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application