An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CP2000 for Biomass Plant Pump & Fan 7th Feb. 2013 John Zuo IABG EMEA

  2. TABLE OF CONTENT • Remote Control in Industry • CP2000 Remote Control Solution • Reference Case • FAQ • Appendix

  3. Remote Control in Industry • Remote Control generally is to control & monitor the site information in centralized room based on EtherNet / IP or Modbus TCP. Centralized Room Modbus TCP EtherNet/IP Modbus WebServer Modbus TCP switch Modbus EtherNet/IP Injection Molding Machine Elevator Conveyor Air-compressor Lighting HVAC

  4. Remote Control in Industry • Current Remote Control Solution Total Solution No Solution in Delta SCADA Solution Delta only can have EN01 module for Server in Modbus TCP. Delta doesn’t have Scanner for EtherNet/IP yet. Scanner or Server Supplier EN01+ CMC MOD01 Delta has client option card for Modbus TCP and adapter option card for EtherNet/IP. Adapter or Client Supplier CMC-MOD01 CMC-EIP01

  5. CP2000 Remote Control Solution • CMC-MOD01 • Support 32 Modbus TCP Servers. • Delta Own solution for server & client. • CMC-EIP01 • Support only 1 Modbus TCP Server. • Support 32 EtherNet / IP Scanners. • Delta only has adapter card no scanner products.

  6. Reference Case • One successful application at Biomass Plant in Italy

  7. Reference Case • The system structure WAGO PLC Centralized Room Modbus TCP CMC-EIP01 Fan & Pump Site

  8. FAQ Can we use DCISoft for finishing the IP setting for this system ? DCISOFT only can set IP for Delta Own products, so for WAGO PLC, we can’t do that in DCISOFT. Hence, if the server is not Delta Products, please use the server software for configuring IP to all products. That is better. Besides, for DCISOFT, it only can set IP configuration to Delta product except HMI, and can’t set common parameter of inverter like frequency source. In this case, why can they use CMC-EIP01 for Modbus TCP? CMC-EIP01 still can & only support 1 server in Modbus TCP. In this case, there is only one server namely WAGO PLC in Modbus TCP, so CMC-EIP01 is OK for CP2000 to communicate in Modbus TCP in this case. Our customer planed to use CMC-MOD01, but no stock, so choose CMC-EIP01. However, we still suggest if you can, please use CMC-MOD01 for Modbus TCP.

  9. FAQ Is the C2000 the same setting as CP2000 in Modbus TCP ? C2000 has the same setting as CP2000 in Modbus TCP for speed mode, so if you know how to set CP2000, you can know C2000. Besides, C2000 can support Torque control in Modbus TCP which CP2000 can’t support, so you can also go to our public folder to download application note about it. EtherNet/IP is better than Modbus TCP ? EtherNet/IP can support more control protocols even including motion since it is designed by AllenBradly. However, for common speed control, Modbus TCP is more suitable for Delta since we have the server already. Of course, you still can use other servers like WAGO in this case. For EtherNet/IP, Delta CMC-EIP01 only support 2000H 2001H 2002H to be controlled.

  10. Appendix Please go to DEN Public Folder to download C2000 application notes < C2000 Modbus TCP in speed mode>, < C2000 Modbus TCP in Torque mode> Please go to 8-9 for knowing the EtherNet/IP information of C2000.

  11. Smarter. Greener. Together. To learn more about Delta, please visit www.deltaww.com.