1 / 64

DEMA TITAN WAREWASH T-812 &T-813

DEMA TITAN WAREWASH T-812 &T-813. Instructional Presentation. The Titan  ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz.

Download Presentation

DEMA TITAN WAREWASH T-812 &T-813

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DEMA TITAN WAREWASH T-812 &T-813 Instructional Presentation

  2. The Titan ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz. The Titanresponds to detergent and rinse triggers in the range of 20V–500V 50/60Hz. The Titanhas been designed for simple installation, set up, and operation. The Titan has an Auto Switchover feature that allows automatic switching from Concentration to Probeless in the case of a probe fault, (and back again if the fault clears). This feature allows continued operation or the dish machine while cutting down on unnecessary service calls. Conditions that can activate this feature are the following: Open probe – a probe wire is disconnected or there is lime buildup on the tips. Closed probe – a piece of flatware may be lying across the probe tips. Detergent not feeding properly – too much or too little detergent.

  3. Chapter Selection 1. Installation 2. Initial Programming 3. System Access 4. Diagnostic Mode 5. Accessories 6. Parts Breakdown Click on the chapter you wish to view

  4. Installation • Wall Mounting • Electrical Connection • Tubing • Conductive Probe

  5. Wall Mounting • Unpack the Titan • Remove mounting plate from Titan (Remove screw and slide plate down) • Attach mounting plate to wall • Replace Titan on the mounting plate (Replace screw)

  6. Unpack Titan

  7. Remove screw and slide Mounting Plate off(downward direction) Removing Mounting Plate

  8. Prior to mounting Titan Location should be based on: • Desired location of Titan and chemicals • Electrical Connection for Titan • Flat vertical surface away from splashing and steam originating from machine • Titan should must be placed so that it can be easily observed and serviced

  9. Attach to Surface

  10. Follow instructions on Mounting Bracket Replace Titan on Mounting Plate

  11. Electrical Connection • Connect power to the Titan per dish machines manufacture's recommendations. Constant power should be supplied to the Titan anytime the dish machine power is on. The Titan can also be plugged directly into a wall socket. • Connect the Detergent Trigger to the machine.( If the Machine does not have a specific trigger connection, then the trigger should be wired to the coil of the Motor Contactor) • Connect the Rinse Trigger to the Machine. (If the Machine does not have a specific rinse trigger connection, then the trigger should be wired to the Rinse Solenoid Valve)

  12. Tubing Connections • Tubing connection from the Titan to the Machine. • Tubing connection from the Titan to the Chemical.

  13. Attaching the Bulkhead Fitting for the chemical injection of a liquid detergent. Inside Outside • Chemical injection fitting must be above the water level in the tank • Chemical Injection fitting should be directly above Conductive Probe

  14. Installing Conductive Probe Inside Outside • The Probe should be installed 2/3 down from water level of the tank • The probe should be installed directly below chemical injection

  15. Click here to return to Main Menu Press Enter to continue to Initial Programming

  16. Initial Programming Enduser accessable menu

  17. Changing Languages • Press to get to language screen • Press to start edit screen • Press or to change languages • Press to accept change

  18. Detergent Prime • Press to scroll to Detergent Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually

  19. Rinse Prime • Press to scroll to Rinse Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually

  20. Sanitizer Prime • Press to scroll to Sanitizer Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually

  21. Detergent Status Display Press to display Status C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Titan is feeding detergent - Titan is not feeding detergent * Screen will stay active for 30 minutes until the up or down arrow is pressed or 30 minutes lapse

  22. Rack Count Rack Count 00000 This is a read only record 0-49999

  23. Descale Press to start Press again to stop

  24. Click here to return to Main Menu Press Enter to continue to System Access

  25. System Access System Access is only available after Initial Programming is completed

  26. Enter Code

  27. Dispenser SetupParameters

  28. Control Mode

  29. Use to enter letters

  30. Use to adjust volume

  31. Click here to return to Main Menu Press Enter to continue to Diagnostic Mode

  32. Diagnostic Mode

  33. Sanitizer Level Detergent Level Rinse Level

  34. C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Concentration mode - not Concentration mode * - When a trigger is present

  35. Rinse Status Screen L – Liquid D - Dry D – Delay R – Rinsing L – Limit Reached Rinse Alarm Set Point Rinse Sensor Reading

  36. Sanitizer Status Screen Sensor Reading Liquid + - running - - not running Sanitizer alarm set Point

  37. Displays total switchover count for OVER and Under feeding Displays total switchover counts for An open probe or shorted probe

  38. Now the Titan is Setup and ready for use. Click here to return to Main Menu Press enter to veiw Accessories

More Related