1 / 31

NX Variable Frequency Drives

NX Variable Frequency Drives. Perfect match for HVAC. Field Devices All you need in HVAC Control. Where are variable frequency drives used?. Buildings: Primarily commercial Applications: Air handling District Heating Room & Zone Operation:

summer-dean
Download Presentation

NX Variable Frequency Drives

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NX Variable Frequency Drives Perfect match for HVAC Field Devices All you need in HVAC Control

  2. Where are variable frequency drives used? • Buildings: • Primarily commercial • Applications: • Air handling • District Heating • Room & Zone • Operation: • Control fans, pumps, compressors to reduce energy consumption

  3. Chiller Cooling tower Ventilation fan Boiler/heating pump Cooling coil Need for AC Drive! Heating coil Where are variable frequency drives used? • Heating, Ventilation and Air Conditioning (HVAC) system

  4. What is a variable frequency drive? • Also known as: Frequency Converter (FC), Variable Speed Drive (VSD), AC Drive, Inverter etc. A squirrel cage motor is the typically used electrical motor in industry and public engineering sector Stepless control for the speed of a squirrel cage motor Cost reductions through Energy savings and improved quality Improved control over the system Smooth and Accurate control

  5. Why use variable frequency drives? • Saves energy through fan and pump speed control • up to 70% energy savings in pump and fan applications • e.g. 32% average savings in a ventilation system → Payback period of 1 year • Decreases mechanical stress due to pressure spikes with direct on-line start & stop • VFDs creates a smooth start which reduces the pressure spikes that reduce system lifetime • Reduces the starting current of the motor • VFDs minimize the starting current of the motor, which means electrical installation investments can be lower Save energy, increase system lifetime, save on investments

  6. Power P % 100 Valve 80 60 40 20 Speed Control 0 20 40 60 80 100 0 Flow Q % Why use variable frequency drives? Saves energy through fan & pump speed control

  7. Savings 81% Payback time: 1.5 90 % Source: ZVEI (Zentralverband Elektrotechnik- und Eletronikindustrie e.V.) years 80 % 70 % 44% 60 % Payback time: 35% 32% 50 % 2 years Payback time: 0.5 Payback time: 40 % year 1 year 30 % 20 % 10 % 0 % Lift Waste water pump Bottling station Ventilation system Why use variable frequency drives? • Energy savings & payback period on investment in VFDs average 32% energy savings & 1 year payback

  8. Pressure spikes in long pipes with direct on-line start & stop Pressure in pipe Direct on-line Start Switch-Off Time Repeated pressure spikes reduces the lifetime of a system Why use variable frequency drives? Reduced mech. Stress increased system lifetime

  9. Why use variable frequency drives? • Reduced starting current Lower electrical installation investments

  10. Honeywell NXLCompact drives 0.25 - 1.5 kW 208 – 240 V0.37 – 3 kW 380 – 500 V Honeywell NXLHVAC drives 0.75 - 30 kW 380 – 500 V 0.55 - 90 kW 208 – 240 V0.75 - 400 kW 380 – 500 V2.2 - 560 kW 525 – 690 V Honeywell NXSMultipurpose drives What does Honeywell offer in VFDs? NX -product family

  11. What’s special about Honeywell VFDs? • Honeywell VFD Highlights (all platforms) • Compact and robust design • Easy commissioning and use • Low audible noise from the motor • High class functionality • High flexibility to fulfill any need • High starting torque & dynamics

  12. Super cooling principle- based channel totally separated from electronics Easily replaceable, temperature controlled cooling fan Separate control unit Removable display panel Integrated Ac choke as standard Easily configurable versatile I/O to meet all requirements Easy to access power terminals Under the protective plate Patented strip solution for proper 360 controls grounding High voltage separated from control electronics Integrated EMC filters as standard What’s special about Honeywell VFDs? • Compact & robust design

  13. DANFOSS 195,3 L 542 % ABB IP54 45/55 kW 124 KG I-level 93,9 L 260 % IP54 45/55 kW 50 KG I-level 35.9 L 100 % Bookcase design 937 591 715 IP54 45/55 kW 35 KG H-level ACS 601 VLT 5060 257 429 421 237 306 495 What’s special about Honeywell VFDs? Honeywell is the Most Compact in the Market!

  14. What’s special about Honeywell VFDs? • Features • Start Up Wizard • The complete product range can be programmed with the help of start-up wizard • Panel – Remove operation • The complete product range have easy change of the control place function • Usefull function when commissioning HVAC applications. • All product behave in similar way • Benefits: • Easy commissioning • Simple to use NEW Press LEFT ARROW for 3 s to change control place Honeywell - the easiest to use and commission

  15. What’s special about Honeywell VFDs? • Features: • High Switching Frequency • Refers to frequency of the IGBT switches in operation • Higher frequency less noise from the motor • Best solution without de-rating • Honeywell offers 6kHz (NXL) and 10 kHz (NXS) compared to 4kHz (Danfoss) • Temperature-controlled fans • Fan stops operating when not needed • Benefits: • Lowest Audible Motor Noise • Reduced Noise caused by the VFD itself • Optimized energy consumption of the drive Highest Switching Frequency = Lowest Noise

  16. Ethernet TCPIP • Profibus DP • CANopen • BACnet • Modbus RTU • Metasys N2 • LonWorks • DeviceNet What’s special about Honeywell VFDs? • Features: • Easy- installable credit-card size option boards • Wide selection of control inputs and outputs • Analog I/Os, relays, digital inputs, thermistor inputs • Wide selection of field buses • Benefits: • Flexible & upgradeable in the field Honeywell VFDs – flexibility to meet any need

  17. What’s special about Honeywell VFDs? • Features: • High starting torque & dynamics • Sophisticated open loop vector control • Automatic torque boost function • Motor auto identification function in entire product family • Benefits: • Excellent performance • Highly accurate motor control • Increased reliability • Smooth start even for high inertia fans • Best flying start in market • Best solution for clean room air handling High performance through excellent motor control

  18. What’s special about Honeywell VFDs? • Honeywell VFD PC Tools • NCload: for easy software downloading • Uses standard RS232 communication port for downloading • Items that can be downloaded: • System software • Application software • Software for option cards • Language package • Activates required application Application loading view Language pack view

  19. What’s special about Honeywell VFDs? • NCdrive- for easy commissioning • Parameter handling for all NX products • Online or Offline Parameter editing • Parameter set comparison • Save or print parameters, graphs, drive information, fault history • Commissioning & maintenance • Graphical window for online drive signal monitoring • Control the drive from the tool: • Start, stop, change direction, reference, fault reset, coast stop • Read active faults & fault history • Service Info Function • Saves all drive information including hardware & software configuration Parameter window Control window Monitoring window

  20. Tell me the technical aspects of NXL compact… • NXL Compact Series • 0,37 – 1,5KW (208 – 240V 1~/3~) • 0,55 – 2,2KW (380 – 500V 3~) • IP20 enclosure class • EMC • N – Level: no emission class • H – Level: comm. standard (external filters available) • Accessories • 1 plug-in for I/0 expanders or field busses • RS232 adapter (for PC connection) • Display panel door installation set • PC tools NXL Compact is a high featured Micro Drive

  21. What’s special about NXL compact series? • Easy Installation: • Flexible installation options (back or side, screw or DIN rail) • Start-up Wizard • Best Features: • Fully programmable I/O, auto-identification, PID controller, flying start) → very high functionality and flexibility against any micro range product • Options: • I/Os, field busses, display panels • RFI filters • AC chokes • Low Audible Noise NXL Compact is a high featured Micro Drive

  22. Tell me the technical aspects of NXL HVAC… • NXL HVAC Series • 0,75 – 30 KW (380 – 500V 3~) • IP21, IP54 enclosure classes • EMC • H – Level: comm. standard • C – Level: comm. special (hospitals, airports) • Accessories • 2 plug-ins for I/O expanders or field busses • RS232 adapter (for PC connection) • Display panel door installation set • PC tools NXL HVAC is a dedicated solution for HVAC

  23. What’s special about NXL HVAC series? • Easy Installation & Set-up: • Quick Installation Guide • 30 second start-up wizard • Extremely low motor noise • High switching frequency • High starting torque & dynamics • Sophisticated open loop vector control & effective design • Suitable for all HVAC applications • Fans, Pumps, Compressors NXL: Perfect for HVAC Applications up to 30kW

  24. What’s special about NXL HVAC series? • Feature: • Quick Installation Guide • Includes 1-page instructions for installation & set-up • Attached to product • Benefits: • Quick & Easy Installation • Most important info available at a glance • Instructions aren’t thrown out with product packaging NXL HVAC: Easiest to Install

  25. What’s special about NXL HVAC series? • Feature: • 30 second start-up wizard • Benefits: • Quick & Easy Installation • VFD programming in just 4 easy steps: • Activate the Start-up Wizard • Select the mode (fan or pump) • Tune the motor nominal speed • Tune the motor nominal current NXL HVAC: Fastest to Set-Up

  26. Tell me the technical aspects of NXS multipurpose… • NXS Multipurpose Series • For open loop applications such as conveyors, mixers, pumps, and fans • 0,37- 90 kW (208-240V ), 0,75 - 400 kW (380-500V), 2,2 - 560 kW (525-690V) • IP21, IP54 (up to 250 kW) enclosure classes • EMC • C – Level: comm. special (optional up to 30KW units) • H – Level: comm. standard (standard up to 160KW units) • L – Level: industrial (standard from 200KW +) • Accessories • 5 plug-ins for I/0 expanders and field busses • Display panel door installation set, through-hole mounting kits • Keypad for Chinese & Cyrillic letters • PC tools NXS is flexible & configurable to meet any need

  27. What’s special about NXS multipurpose series? • Easy Installation: • Start-up wizard • Alpha-numeric display panel, memory and back-up functions • Flexibility • Variety of option boards & slots • Wide Power and Voltage range • Alpha-numeric display panel, memory and back-up functions • 7 predefined application software to ensure suitability to any application • Several special application software available NXS is flexible & configurable to meet any need

  28. What’s special about NXS multipurpose series? • Features: • Hardware-coded option boards & slots • 5 option board slots with 20 different boards to select • Isolated thermistor input as standard • Benefits: • Real flexibility to fulfill any need from the application NXS is flexible & configurable to meet any need

  29. When to choose NXS over NSL? • Why choose NXS multipurpose over NXL HVAC? • applications over 30kW (up to 400kW) • alphanumeric display with memory • More comprehensive start-up wizard • PID with real units (bar, psi, etc.) • Parameter copy & back-up • Special panel for Cyrillic & Chinese letters • Multi-monitor view (3 values simultaneously) • 10 kHz switching frequency without de-rating (up to 30kW) • wider selection of special application software • Water Solutions Package: Multi-master Pump Cascade Controller, Sewage Tank Level Controller • Extra PID Controller i.e. NXS controlling an actuator • More I/O options: 5 option board slots instead of just 1 or 2

  30. How do Honeywell NXL VFDs compare?

  31. How do Honeywell NXS VFDs compare?