1 / 8

Rahul Ganguli Teledyne Scientific 10/18/12

Cal Poly field site panel testing results. Rahul Ganguli Teledyne Scientific 10/18/12. Dean E. Wendt & Lenora Brewer Center for Coastal Marine Sciences Biological Sciences Department California Polytechnic State University San Luis Obispo, CA 93407. Barnacle removal testing.

suzuki
Download Presentation

Rahul Ganguli Teledyne Scientific 10/18/12

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cal Poly field site panel testing results Rahul GanguliTeledyne Scientific10/18/12 Dean E. Wendt & Lenora BrewerCenter for Coastal Marine SciencesBiological Sciences DepartmentCalifornia Polytechnic State UniversitySan Luis Obispo, CA 93407

  2. Barnacle removal testing *CRS on intersleek coatings are usually between 0.8 and 2.0 N/mm2 depending on which exact formulation and other variable factors, so these CRS values are relatively high.

  3. Streamer section A Thin Si Fluoro polymer Thin Si ABR ABL AFL AFR Missing after pics, but I think you took some on your phone • All barnacles broke when removed via force gauge, no CRS calculated • Average % BPR was 65% • Water jet results: • 13% macrofouling remained • 13% barnacles remained • Average CRS =0.44 N/mm2 with only 40% removing completely • Average % BPR was 47% • Water jet results: • 15% macrofouling remained • 10% barnacles remained • Large portions of coating peeling/torn

  4. Streamer section B Thick Si Fluoro polymer Thick Si BBL BBR BFR BFL BFR after Water jet BFL after Water jet • Average CRS = 0.45 N/mm2 with 83% removing completely • Average % BPR was 8% • Water jet results: • 10% macrofouling remained • 80% barnacles remained • Coating peeled/tore in small areas with barnacle removal • Average CRS =0.56 N/mm2 with 100% removing completely • Average % BPR was 3% • Water jet results: • 7% macrofouling remained • 67% barnacles remained

  5. Streamer section C Thin Si + Copper Fluoro polymer Thin Si +Copper CBR CBL CFR CFL CFR after Water jet CFL after Water jet • Average CRS = 0.39 N/mm2 with 86% removing completely • Average % BPR was 8% • Water jet results: • 20% macrofouling remained • 10% barnacles remained • Coating peeled/tore in small areas with barnacle removal • Average CRS =0.51 N/mm2 with 31% removing completely • Average % BPR was 43% • Water jet results: • 56% macrofouling remained • 89% barnacles remained • Coating peeled/tore in small areas with barnacle removal

  6. Streamer section D Thick Si + Copper Fluoro polymer Thick Si +Copper DBR DBL DFR DFL DFL after Water jet DFR after Water jet • Average CRS = 0.30 N/mm2 with 80% removing completely • Average % BPR was 13% • Water jet results: • 60% macrofouling remained • 93% barnacles remained • Average CRS =0.45 N/mm2 with 43% removing completely • Average % BPR was 26% • Water jet results: • 65% macrofouling remained • 73% barnacles remained

  7. Streamer section E Polyurethane control EBR EBL EFL EFR DFR after Water jet EFL after Water jet • All barnacles broke when removed via force gauge, no CRS calculated • Average % BPR was 81% • Water jet results: • 40% macrofouling remained • 60% barnacles remained

  8. Streamer section F Copper control FBL FBR FFL FFR FFR after Water jet FFL after Water jet No fouling observed on copper control except perhaps a thin layer of biofilm, or slime.

More Related