200 likes | 334 Views
TrueSTEAM ™ Humidification Systems. Module 5: Wiring and Controls. Module 5: Wiring and Controlling TrueSTEAM. What dips to set for different controls How to wire different controls When to choose one control over another. Key Learning
E N D
TrueSTEAM™ Humidification Systems Module 5: Wiring and Controls
Module 5: Wiring and Controlling TrueSTEAM • What dips to set for different controls • How to wire different controls • When to choose one control over another Key Learning Which humidity controls to use and how to configure them
DIP 1-2 = Flush timings DIP 3 = RedLINK DIP 4 = Power monitoring DIP 5 = Air proving DIP 6 = not used 4 2 3 1 6 5 Getting Started • Unplug TrueSTEAM and remove cover • Locate DIP Switches
DIP 3 – RedLINK™ Wireless Technology • DOWN: RedLINK disabled, use conventional terminals • UP: RedLINK enabled, use ABCD terminal Prestige HD Thermostat Wireless Adapter Conventional Terminals
DIP 4 – Power Monitoring • Down: TrueSTEAM looks for R and C input before allowing humidity • Use when humidity control is separate from system control • UP: TrueSTEAM R and C input disabled • Use when humidity control is integrated with system control
System Fan Regulation • Breaking G: Use when humidity control is separate from system fan control. • Fan delay advantage • Not breaking G: Use when humidity control is integrated with system fan control. • Simple wiring advantage
DIP 5 – Air Proving • DOWN: Air proving disabled. • UP: Air proving enabled. • Added safeguard for air movement
Wiring VisionPRO® IAQ DIP 4
Prestige™ RedLINK Connection DIP 3 DIP 4
Support Materials • Detailed Training Materials on Installation Available!Visit www.forwardthinking.honeywell.comEnter literature form:#69-2285: TrueSTEAM Installation Manual
Module 5: Wiring and Controlling TrueSTEAM • What dips to set for different controls • How to wire different controls • When to choose one control over another Key Learning Which humidity controls to use and how to configure them