1 / 50

Ph. D. Defense

Ph. D. Defense. Committee: Chair: J. H. Edgar Advisor: B. D. DePaola Member: C. L. Cocke Member: C. D. Lin Member: P. M. A. Sherwood Presenter: Hai T. Nguyen. MOTRIMS: Magneto-Optical Trap Recoil Ion Momentum Spectroscopy. Hai Nguyen, Richard Br é dy, Xavier Fl é chard,

taariq
Download Presentation

Ph. D. Defense

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ph. D. Defense • Committee: • Chair: J. H. Edgar • Advisor: B. D. DePaola • Member: C. L. Cocke • Member: C. D. Lin • Member: P. M. A. Sherwood • Presenter: Hai T. Nguyen

  2. MOTRIMS: Magneto-Optical Trap Recoil Ion Momentum Spectroscopy Hai Nguyen, Richard Brédy, Xavier Fléchard, Alina Gearba, How Camp, Takaaki Awata, Johnathan Sabah, Kyle Wilson, and Brett DePaola.

  3. OUTLINE • Reviews of Cold Target Recoil Ion Momentum Spectroscopy • Motivation • Experimental Setup • Results • Conclusion and Outlook

  4. For charge transfer: COLTRIMS: Principles • Cold Target Recoil Ion Momentum Spectroscopy is a technique in which information about the collision is obtained through the measurement of the momentum transferred to the ionized target (atom/molecule). p P’ p q P p p r || p r ┴ r Q: energy defect : Scattering angle (Lab frame) Prll , Pr: parallel and perpendicular recoil momentum components PP , PP’ : projectile momentum before and after the collision Vp: projectile velocity nc: number of transferred electrons

  5. COLTRIMS: Pros & Cons • Pros: • This technique allows kinematically complete experiments. • The good resolution in the measured longitudinal recoil ion momentum allows accurate determination of the inelasticity in the collision and therefore identification of the different collision channels by their different Q-values. • Cons: • Ultimately, in COLTRIMS, the resolution is limited by the temperature of the target (>100 mK) traditionally delivered by a supersonic jet. • Problematic for collisions with excited target.

  6. MOTIVATION • Collisions with excited target (~ 20%). • Resolution is no longer limited by target temperatures (~ 130mK). • Cross-section measurements provide rigorous test for theory.

  7. EXPERIMENTAL SETUP

  8. EXPERIMENTAL RESULTS • Results Obtained: • Energy dependent Cs+ + Rb (5l), l = s and p • Energy dependent Na+ + Rb (5 l), l = s and p • MOTRIMS probes MOT excited state fractions • Systems with energetically degenerate channels (Dual beam method) • Li+ + Rb • K+ + Rb • Rb+ + Rb • Results will be shown for: • 7 keV Na+ + Rb (5l), l = s and p • Na+ + Rb (5l)compare with theory • MOT excited state populations • Rb+ + Rb(5l), l = s and p

  9. 5s-3p 5p-3p 5p-4s 5s-3s RESULTS7 keV Na+ + Rb (5l), l = s and p

  10. RESULTS7 keV Na+ + Rb (5l), l = s and p Laser off

  11. MOTRIMS as a probe7 keV Na+ + Rb (5l), l = s and p

  12. RESULTS7 keV Na+ + Rb (5l), l = s and p

  13. RESULTS7 keV Na+ + Rb (5l), l = s and p

  14. RESULTS7 keV Na+ + Rb (5l), l = s and pCompared to calculation

  15. ENERGY-DEPENDENT RESULTSCompared to calculation

  16. ENERGY-DEPENDENT RESULTSCompared to calculation 5s-3p 5p-3p (keV mrad) (keV mrad)

  17. MOTRIMS as a probe7 keV Na+ + Rb (5l), l = s and p

  18. MOTRIMS as a probe7 keV Na+ + Rb (5l), l = s and p

  19. MOTRIMS as a probe7 keV Na+ + Rb (5l), l = s and p

  20. 3 5p 2 1 0 2 5s 1 MOTRIMS as a probe7 keV Na+ + Rb (5l), l = s and p

  21. Other Collision System: Difficulty

  22. RESULTS7 keV Rb+ + Rb (5l), l = s and p s5s-5p/s5p-5s = 2.95 ± 0.05

  23. RESULTS7 keV Rb+ + Rb (5l), l = s and p

  24. RESULTS7 keV Rb+ + Rb (5l), l = s and p s5s-5p/s5p-5s = 2.95 ± 0.05 DCS for resonant channels are more forwardly peaked 5s-5s Oscillatory Structure 5p-5p No Oscillatory Structure

  25. SUMMARY • ‘Simultaneous’ measurements of excited state fraction and relative cross sections. • Kinematically complete collisions study for alkali ion – trapped atoms including energetically degenerate systems. • MOTRIMS is a powerful tool for ion-atom collisions. • Using MOTRIMS as a probe at MOT dynamics under some perturbation.

  26. THANKS • Committee Members • MOTRIMS Group • JRML Support Staff: • Kevin Carnes, Scott Chainey, Charles Fehrenbach, Bob Geering, Bob Krause, Vince Needham, Al Rankin, Carol Regehr, and Mike Wells.

  27. Questions & Answers • Cooling and Trapping • Optics Layouts • Experimental Setup • Analysis • Excited State Formula? • Others Systems

  28. DAVLL Sat abs O I /2 REPUMP Com AOM 80MHz Blocker F=40cm TRAPPING OPTICS F=40cm /2 O I TRAP Sat abs DAVLL Q&A SIMPLE OPTICS LAYOUT

  29. Q&A SIMPLE OPTICS LAYOUT l /2 PBS l /4 Mirror Mirror From AOM l /4 l /2 l /4 Mirror PBS l /4 TRAPPING OPTICS l /4 Mirror Mirror l /4 Mirror

  30. Mass a.u. 2 keV s 5 keV s 7 keV s 6 8.268E-5 8.548E-5 8.623E-5 23 7.538E-5 8.086E-5 8.232E-5 39 7.087E-5 7.801E-5 7.991E-5 85 6.162E-5 7.216E-5 7.497E-5 133 5.442E-5 6.761E-5 7.112E-5 -- Q&A Projected TOF

  31. Independent of excited state measurements: Q&A RESULTS7 keV Na+ + Rb (5s, 5p)

  32. 3 5p 2 1 0 2 5s 1 Q&A Cooling and Trapping B + - Rb VZ z Optical frequency m = +1 m = 0 j=1  m = -1 + - LASER m = +1 m = -1 z j= 0

  33. Q&A RESULTS7 keV Li+ + Rb (5l), l = s and p

  34. Q&A RESULTS7 keV Li+ + Rb (5l), l = s and p

  35. Q&A Multi-Projectile Source

  36. Q&A Probe: 7 keV Na+ + Rb (5l) Known

  37. Q&A 7 keV Li+ + Rb (5l) Known Results

  38. Q&A Cross Sections 7 keV Li+ + Rb Waiting for TC-AOCC results

  39. Q&A 7 keV Li+ + Rb Scattering Angle Information

  40. Q&A 7 keV Li+ + Rb Scattering Angle Information • Grouped scattering angle information are hard to extrapolate (Rb + Rb). • Theoretical Comparison not trustworthy. • Using a weighted method to deduce individual channel scattering angle information.

  41. Q&A 7 keV Li+ + Rb Scattering Angle Information Laser on Laser off

  42. Q&A 7 keV Li+ + Rb Scattering Angle Information

  43. Q&A RESULTS6 keV Cs+ + Rb (5l), l = s and p

  44. Q&A RESULTS6 keV Cs+ + Rb (5l), l = s and p

  45. Q&A SINGLE CAPTURE IN 6 keV Cs+ + Rb (5l), l = s and p • Recoil ion PSD image

  46. Q&A RESULTSEnergy dependent Cs+ + Rb (5l), l = s and p

  47. Q&A Excited State Fraction Formula?

  48. Specific Example: 87Rb MF Levels! MF Levels! F=3 -3 -2 -1 0 +1 +2 +3 15 10 6 3 1 52P3/2 F=2 F=1 5 8 9 8 5 F=0 Trapping Laser F=2 52S1/2 -2 -1 0 +1 +2 F=1 So, What’s the Problem!? Q&A So, What’s the Problem!?

  49. Here’s the problem! Here’s the problem! So, What’s the Problem!? Q&A So, What’s the Problem!? Beam Symmetry? I2 = 0.45 mW / cm2 B-Field Gradient? I1 = 0.50 mW / cm2

  50. Preliminary Results Q&A Preliminary Results

More Related