1 / 18

Fabrication of Capsules with Angle Dependent Gold shims for Hohlraum Drive Symmetry Correction

A. Nikroo 1 , J. Pontelandolfo 1 , A.Z. Greenwood 1 , J.L. Stillwell 2 , D. Callahan 3. 1 General Atomics 2 University of California, Berkeley 3 Lawrence Livermore National Laboratory. Fabrication of Capsules with Angle Dependent Gold shims for Hohlraum Drive Symmetry Correction.

taber
Download Presentation

Fabrication of Capsules with Angle Dependent Gold shims for Hohlraum Drive Symmetry Correction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A. Nikroo1, J. Pontelandolfo1, A.Z. Greenwood1, J.L. Stillwell2, D. Callahan3 1 General Atomics 2 University of California, Berkeley 3 Lawrence Livermore National Laboratory Fabrication of Capsules with Angle Dependent Gold shims for Hohlraum Drive Symmetry Correction 15th International Symposium on Heavy Ion Fusion PPPL Princeton, New Jersey June 7-11, 2004 Work performed under General Atomics Internal R&D program

  2. Innovation in target design and fabrication can be used to compensate for drive asymmetry • In the HIF hybrid target, most of the energy is deposited behind a shine shield • Radiation flows around the shield and results in a bright source around the shield • This causes a large P4 asymmetry • The P4 asymmetry can be corrected using a shim to remove excess radiation • Initial examination of this concept was done on a target shot in SNL’s double ended Z-pinch Z-axis Au shim Ge-CH equator XY Shims can be used to fix asymmetries in all indirect drive targets (heavy ion, laser, z-pinch)

  3. Summary of angle dependent gold shim fabrication process • Ge-CH mandrels were made using well developed ICF capsule fabrication techniques • Gold shim coating was deposited by magnetron sputtering • Using masks patterned coatings were produced • Coatings on flats were used as initial guidelines • Gold thicknesses on shells were determined by x-ray transmission (contact radiography) • Profile similar to desired profile was produced • Adjustments to process is necessary to obtain desired profile

  4. The decomposable mandrel technique was used to fabricate Ge-CH shells Heat Coat Decomposable Mandrel: Final Ge-CH shell Glow discharge Polymer coating Poly-a-methylstyrene (PAMS) (GDP) • Process allows fabrication of shells with: • Desired diameter (~ 5 mm) • Wall thickness (~ 20-30 µm) • Sphericity (>99.9%) • Wall thickness uniformity (<0.2 µm) • Dopant content (germanium- ~ 2 at.%) High aspect ratio- fragile

  5. The desired gold shim profile was a combination of P2 and P4 Legendre polynomials Desired shim profile for this experiment was: • The relative contribution of P2 and P4 needed to be an adjustable parameter • Shim coating process had to be flexible enough to accommodate such changes: • Use of multiple masks • Adjustment of mask-shell distance XZ Projection vs. polar angle Designed to zero out P2, P4 double ended Z-pinch asymmetry

  6. Gold coating was deposited using physical vapor deposition via magnetron sputtering Vacuum Chamber Au target -500 V Ar+ Impact Mask Spinning Pan xyz Micro-manipulator Ge-CH mandrel Motor • Sputtering provides an important processing knob • Background argon pressure determines mean free path of gold atoms • Affects scattering and deposition pattern of gold atoms • Masks were used to pattern gold coating Sputter system

  7. Combination of coatings through two different masks could be used to obtain different profiles 7.5 10 1.085 5 Single 2.31 2.2 1.085 Double • Aluminum plate with precision milled slots was used as mask • Varying slot dimension varied coating profile • Single and double slot masks could be combined to fine tune pattern Combination mask Coatings on flat substrates

  8. Gold coating pattern could also be changed by varying the mask-substrate distance Movable mask • For a given mask the separation between mask and substrate could be changed • Coatings spread with separation of mask from substrate • This allowed obtaining various profiles by adjusting mask-substrate distance 1mm 2mm Coatings on flats

  9. The desired profile could be produced on flats very closely Actual Desired • Coatings using: • ~ 2mm mask-substrate distance • 0.8* single slot + 1.0 double slot • produced desired pattern on flats • Coatings on shells were likely to be deficient near the poles • This, however, was used as a starting point for producing the shim on shells • Coating rate on shells needed to be determined

  10. Characterization of coatings on shells provided a difficult challenge • Interferometry or profilometry were not possible • X-ray transmission detected by contact radiography was readily available and used: • Convolution of x-ray source, coating, x-ray film signal was calibrated on flats • X-ray signals was linear for the range of interest • Uncoated shell signal was subtracted • Shell signal was corrected for cord length in ZX projection • Data near poles suffers from saturation due to large cord length

  11. Coatings on flat substrates were used to calibrate x-ray transmission signal X-ray Interfer • Coatings through single and double slots on flats were measured by interferometry • Coatings were duplicated on thin CH film (~ zero substrate signal) • X-ray signals were recorded using various tube voltage and exposure times • The settings that led to highest x-ray vs. interferometry linearity were used for measuring shells • It also allowed thickness determination on shells Single mask coating 8 bit digitized line out

  12. X-ray signal was linear in most of the range of interest ZX profile cord length of desired profile • X-ray signal measures projection of shells thickness on ZX plane • Cord length for desired profile is ~ 0.5-1.2 µm • X-ray signal is linear vs. thickness for this range • Proper exposure and source voltage settings are required! • Region of linearity could be changed by changing settings

  13. Shells were precisely positioned under the masks • Shells were mounted on ~ 200 µm tungsten stalks • Stalk was attached to motor shaft with wobble of < ~ 50 µm • Interferometer was used to determine position of top of shell to < 1 µm • Measuring microscope was used for lateral position determination (~1 µm) • XYZ micrometer stage was used to move mask over shells to within ~ 2 µm Tungsten stalk Shell mounting for coating

  14. X-ray signal from shells coated through single mask was used to determine coating thickness shell flat Uncoated shell ZX thickness projection Au coated shell • Single slot pattern on shell was very similar to that on flats • X-ray exposure settings were changed for these thinner coatings

  15. shell flat X-ray signals from double slot mask indicated lower rate near equator Au coated shell • Coatings using double slot mask were thicker near equator and thinner at the poles than expected from flat data • Shell curvature and larger distance between poles and mask are responsible • Data analyzed after shells were delivered for shots • We will make adjustments for next series ZX thickness projection

  16. A profile similar to the desired profile was produced on target shells actual desired • Final profile was not exactly as desired on shells delivered for shots • Coating near equator was thicker than desired- would it reverse P2 asymmetry? • Coating near poles was thinner • Adjustment of the double slot mask is needed • Shells were assembled and shot at SNL P2 symmetry was reversed in shot on SNL Z-pinch as expected

  17. We hope to simulate process using Monte Carlo simulation to obtain better predictive capability • Direct Monte Carlo simulation program DS2V of G. Bird • Initially determine gold atom distribution near masks • Use that distribution to simulate coating under masks as function of distance on flat and spherical substrates

  18. We have produced angle dependent gold shim targets • This innovative target can compensate for driver asymmetry • Targets were produced using ICF target fabrication infrastructure at General Atomics • Gold coating thickness could be patterned by coating shells through: • Various masks • Adjusting mask-substrate distance • The desired pattern was nearly produced • However, adjustments are needed to faithfully produce desired profile • Other characterization techniques also need to be examined in the future