1 / 25

Basic Principles of X-Ray Inspection for BGA’s

Basic Principles of X-Ray Inspection for BGA’s. Increased Use of BGA’s. Ball Grid Arrays - array of solder ball connections underneath component Provides many advantages over leaded components Reduced component size Increased I/O count Smaller footprint

tamber
Download Presentation

Basic Principles of X-Ray Inspection for BGA’s

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Basic Principles of X-Ray Inspection for BGA’s

  2. Increased Use of BGA’s • Ball Grid Arrays - array of solder ball connections underneath component • Provides many advantages over leaded components • Reduced component size • Increased I/O count • Smaller footprint • Increased performance characteristics

  3. The Problem with BGA’s • How to verify a solder bond that cannot be observed? • Hidden joints - touch up not possible • Only way to test integrity of joints • Electrical test • Look Under/Video Scope • X-Ray

  4. Presence or Absence of Material wedge object x-rays x-rays detector image Differences in Material Density high density material x-rays low density x-rays detector image How X-Rays Work

  5. X-ray tube generates x-ray energy The image you see X-rays absorbed where density exists in sample - remaining x-rays pass through & strike the detector Detector converts x-rays to visible light, video camera sends image to processor Image Processor enhances x-ray images for high-resolution viewing How an X-Ray System Works

  6. Solder Connections Under X-Ray Analysis • Main characteristic: uniformity of the connections • If X-ray shows all connections uniformly circular & equal in area - good indication of complete/proper reflow

  7. Nearly all Defects have “Signatures” • Bridging, missing balls, large voids obvious • Other defects subtle • Look for pattern in distortion of size/shape of bond image • Operator learns to identify defect signatures, process problems and quickly make adjustments

  8. Look Under Scope Image Defects Identified by X-Ray: Bridging • May be due to excess paste or flux • Improper rework implicated • Solder splattering due to poor reflow conditions

  9. Misregistration • Result of errors in component placement • Possible issues with solder mask alignment

  10. Insufficient Reflow • More difficult to spot • If package misplaced, ball shape may be elliptical (easier to identify) • Bond distribution not consistent

  11. Missing Balls • Can occur in manufacturing process • Usually due to mishandling

  12. Cold Solder • More difficult to identify • Signified by jagged irregular edge around the perimeter of the solder ball

  13. Solder Voids • Result of moisture in BGA package – must be thoroughly baked out • Problems with solder paste • Huge issue with lead-free solder

  14. Solder Voids • Voids a process indicator, not defect unless excessively large • Motorola Study - balls that contain voids up to 24% more reliable than those without voids!

  15. At 50 kV At 70 kV Solder Voids & Voltage Blooming • Associated with camera used in many X-ray systems • As voltage increased, void artificially appears to expand (bloom) • Makes void appear larger than it really is • Glenbrook systems not subject to voltage blooming

  16. Normal Potato Chipping Potato Chipping/Popcorning • BGA’s outside edge lifts up from a pad • Center joints squashed due to compression under die area • Caused by moisture in BGA or excessive topside temperature

  17. Potato Chipping/Popcorning • Note distortion/ warpage of ball bonds lower right corner • View through Look-Under scope. Note package peeling away from solder ball

  18. Opens (require angled viewing) • Ball smaller than adjacent balls • Pad shadow seen below indicating no contact between ball & pad • Note two unattached spherical shapes unlike oval shapes adjacent to it • indicate no contact between pad & solder ball

  19. RTX-113HV X-Ray Inspection System • Features powerful 80 kV X-ray tube • GTI-5000 image processor with auto-BGA analysis software • Sees through dense multilayer PCBs & metal capped BGAs • Variable Angle Viewing allows for 45 degree viewing

  20. GTI-5000 Image Processing Software • Provides analysis of BGA defects: bridging, voids, missing balls • Measures BGA ball size, ball roundness & void size • Software identifies any ball outside of set tolerance • Includes CPU, Frame Grabber, Software, Color Monitor

  21. Variable Angled Viewing • Allows for 45 degree viewing • X-Ray source is rotated • Allows inspection for full range of hidden BGA defects: • Missing or mis-registered solder spheres • Misalignments • Gross solder voids • Non-wetting or non-contact

  22. Specifications: RTX-113HV • Operating voltage: 120V, 50/60 Hz • Energy sensitivity: < than 15kV to >160 kV • X-Ray Tube – 80 kVA • Resolution: >20 line pairs per millimeter; can easily resolve a 1 mil bond wire • Magnification: 4 - 50x • Maximum field of view: 1” diameter circle • Maximum PCB size: 27” x 27” (685mm x 685mm) with PCB manipulator

  23. RTX-113 RTX-Mini JewelBox Series • 35-52kV • 20 line pairs/mm resolution (up to 100 optional) • Variable Angle Viewing option available • 40kV • 20 line pairs/mm resolution • Truly Portable – can be hand carried or shipped! • 80 or 90kV • 5-7, or 10 micron Focal Spot size • 7x-2000x magnification • 5 Axis, 360o Positioner Other Real-Time X-Ray Inspection Systems from Glenbrook Technologies

  24. Manufacturer’s RepAaron Caplan1310 E. Maple AveSterling, VA 20164(703) 731-8048aaron@gsaservice.com www.gsaservice.com 11 Emery AveRandolph, NJ 07869Tele: (973) 361-8866Fax: (973) 361-9286szweig@glenbrooktech.com www.glenbrooktech.com

  25. Manufacturer’s RepAaron Caplan1310 E. Maple AveSterling, VA 20164(703) 731-8048aaron@gsaservice.com www.gsaservice.com 11 Emery AveRandolph, NJ 07869Tele: (973) 361-8866Fax: (973) 361-9286szweig@glenbrooktech.com www.glenbrooktech.com