1 / 32

EEG/MEG Source Localisation

EEG/MEG Source Localisation. Jérémie Mattout & Christophe Phillips. ?. SPM Short Course – Wellcome Trust Centre for Neuroimaging – May 2007. EEG/MEG Source localisation. Introduction. Data Preprocessing. Source reconstruction. Scalp Data Analysis. Statistical Parametric Mapping.

tamera
Download Presentation

EEG/MEG Source Localisation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EEG/MEG Source Localisation JérémieMattout & Christophe Phillips ? SPM Short Course – Wellcome Trust Centre for Neuroimaging – May 2007

  2. EEG/MEG Source localisation Introduction Data Preprocessing Source reconstruction Scalp Data Analysis Statistical Parametric Mapping Dynamic Causal Modelling

  3. Forward Computation (K) Inverse Computation EEG/MEG generative model EEG/MEG sources Equivalent Current Dipoles (ECD) Imaging or Distributed EEG/MEG inverse methods EEG/MEG Source localisation Overview

  4. Equivalent Current Dipoles (ECD) Imaging or Distributed EEG/MEG inverse methods EEG/MEG Source localisation An ill-posed inverse problem • Jacques Hadamard (1865-1963) • Existence • Unicity • Stability « Will it ever happen that mathematicians will know enough about the physiology of the brain, and neurophysiologists enough of mathematical discovery, for efficient cooperation to be possible ? »

  5. Equivalent Current Dipoles (ECD) Imaging or Distributed EEG/MEG inverse methods EEG/MEG Source localisation An ill-posed inverse problem • Jacques Hadamard (1865-1963) • Existence • Unicity • Stability Prior information is needed

  6. ? Likelihood Posterior Priors EEG/MEG Source localisation Bayesian Formulation « Will it ever happen that mathematicians will know enough about the physiology of the brain, and neurophysiologists enough of mathematical discovery, for efficient cooperation to be possible ? » Jacques Hadamard Bayes’ Rule Y: data J : sources M: model assumptions Gaussian densities: defined by their means and variances

  7. Inversion EEG/MEG Source localisation General procedure

  8. EEG/MEG Source localisation User interface File manager Current Analysis Meshing Co-registration Forward computation Inverse solution

  9. EEG/MEG Source localisation Anatomical model – Source space Individual cortical mesh MNI Space Canonical mesh Subject’s MRI [Un]-normalising spatial transformation Anatomical warping Cortical mesh

  10. EEG/MEG Source localisation Coregistration From Sensor to MRI space EEG fiducials HeadShape Rigid Transformation + Surface Matching Full setup HeadShape MRI derived meshes MEG

  11. EEG/MEG sources EEG/MEG Source localisation Forward Computation Computing the operator K # dipoles 1 sphere 3 spheres K # sensors Lead field matrix

  12. Head model Mesh shape and size EEG/MEG Source localisation Data Likelihood Linear Generative Model ModelM

  13. EEG/MEG Source localisation Priors on the sources Incorporating Multiple Priors # dipoles … # dipoles IID (Minimum Norm) Spatial smoothness (LORETA) Multiple sparse priors (MSP)

  14. Head model Mesh shape and size EEG/MEG Source localisation Parametric Empirical Bayesian Inference (I) Hierarchical model ModelMi 2nd Level … … 1st Level Likelihood Prior Posterior Evidence

  15. - PEB inference yields posterior estimates: J, C,λandμ - Knowing J and C, Posterior Probability Maps (PPM) can be computed EEG/MEG Source localisation Parametric Empirical Bayesian Inference (II) EM/ReML algorithm M-step E-step ^ ^ ^ ^ ^ ^

  16. p(Y|Mi) model Mi 3 1 2 EEG/MEG Source localisation Parametric Empirical Bayesian Inference (III) Model comparison

  17. EEG/MEG Source localisation Conclusion First level analysis PEB PPM Second level analysis Individual summary statistics … RFX analysis p < 0.01 uncorrected SPM

  18. To be continued…

  19. Forward Computation (K) Inverse Computation EEG/MEG generative model EEG/MEG sources EEG/MEG Source localisation ECD approach Equivalent Current Dipoles (ECD) Imaging or Distributed EEG/MEG inverse methods

  20. EEG/MEG Source localisation Y = KJ + E Problem to solve: ECD approach: model • A priori fixed number of sources considered, (usually less than 5) •  over-determined but nonlinear problem • iterative fitting of the 6 parameters of each source K depends on the source location r → non-linear relationship with Y : Y = K(r) J + E J are the source intensity (incl. orientation) → linear relationship with Y, once K is fixed: J = K Y and Y = K J ^ - ^ ^

  21. EEG/MEG Source localisation • The iterative optimisation procedure can only find a local minimum • thestarting location(s) used can influence the solution found ! Value of parameter 1D example of optimisation problem: Cost function Local minimum Local minimum Global minimum ECD approach: optimisation

  22. EEG/MEG Source localisation ECD approach: results • For an ECD solution, initialise the dipoles • atmultiple random locationsand repeat the fitting procedure  cluster of solutions ? • at a«guessed» solutionspot, • then let the dipole free to move • keep the location fixed (also named « seeded-ECD ») • Eventually, • Simple focused solution: dipole coordinates • Time course of activity for each dipole

  23. EEG/MEG Source localisation ECD approach: interpretation and limitation • How many dipoles ?The more sources, the better the fit… in a mathematical sense !!! • (Still the number of sources limited : 6xNs < Ne) • Moreover it is NOT possible to mathematically compare 2 models with different number of sources ! • Is a dipole, i.e. a punctual source, the right model for a patch of activated cortex ? • What about the influence of the noise ? Find the confidence interval. • Is the seeded-ECD a good approach ? Given that you find what you put in…

  24. EEG/MEG Source localisation ECD approach: application epilepsy 2D EEG map of first peak, above F4 front L R back

  25. EEG/MEG Source localisation Anatomically constrained spherical head models, or pseudo-spherical model. Forward Problem: analytical vs. numerical solution • The head is NOT spherical: •  cannot use the exact analytical solution because of model/anatomical errors. • Realistic model needs BEM solution: •  surfaces extraction •  computationnaly heavy •  errors for superficial sources • Could we combine the advantages of both solutions ?

  26. EEG/MEG Source localisation Scalp (or brain) surface Best fitting sphere: centre and radii (scalp, skull, brain) Spherical transformation of source locations Leadfield for the spherical model Anatomically constrained spherical model

  27. EEG/MEG Source localisation Anatomically constrained spherical model • Dipole: • defined by its polar coordinates (Rd,IRM, qd, fd ) • Fitted sphere: • defined by its centre and radius, (cSph,RSph) Direction (qd,fd) Fitted sphere Rscalp(qd,fd) Rd,IRM RSph Scalp surface cSph

  28. EEG/MEG Source localisation Fitted sphere and scalp surface Application: scalp surface

  29. EEG/MEG Source localisation Application: cortical surface

  30. EEG/MEG Source localisation

  31. EEG/MEG Source localisation Priors on the sources (II) Hyperpriors • Log-normal hyperpriors • Enforces the non-negativity of the scale parameters • Enables Automatic Relevance Determination (ARD)

More Related