1 / 17

Patient monitoring and Diagnostic Equipment Solutions

Patient monitoring and Diagnostic Equipment Solutions. Medical Solutions. Introduction Purpose Introduce Intersil solutions for patient monitors and medical diagnostic equipment Objectives Overview of several sub-blocks of the patient monitor systems and various medical diagnostic equipment

tamma
Download Presentation

Patient monitoring and Diagnostic Equipment Solutions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Patient monitoring and Diagnostic Equipment Solutions

  2. Medical Solutions • Introduction • Purpose • Introduce Intersil solutions for patient monitors and medical diagnostic equipment • Objectives • Overview of several sub-blocks of the patient monitor systems and various medical diagnostic equipment • Present Intersil feature products with select application circuits • Content • 16 pages • Learning time • 30-40 minutes (estimated)

  3. Patient Monitors –High Level System

  4. Intersil Products Products Highlighted • Op Amps • Data Converters • Switches and Multiplexers • RS-485/422 Interfaces • Voltage references • Digital Potentiometers (DCPs) • Real Time Clocks • PWM Controllers • Integrated FET Switching Regulators • Isolated Power • Battery Chargers • Voltage monitoring Other Intersil Products • Ambient Light Sensor/Proximity Detector • LED Backlighting • Audio Amplifiers

  5. ECG / EKG • ECG signals basics • Typically 0.05 Hz to 150 Hz bandwidth, 1mV to 10mV pp • Systems are EMI sensitive Analog Frontend Requirements • Low noise at low frequency, high impedance (low leakage) components are required • ISL28110 for low noise, high impedance body probe buffers • ISL28217 for right leg drivers • Other analog components: • ISL54500 for lead switching • ISL21009D for low power VREFs • Accuracy depends on AC or DC coupling approach from 10-bit to 16-bit. • Power • Multi output voltage solutions for powering processors or FPGA • ISL9440A triple output controller and single LDO controller generates the rails for a FPGA. • ISL80101 LDO family can reduce EMI in noise sensitive areas.

  6. Blood Pressure (NiBP)- Non-Invasive Blood Pressure Pressure Sensor Basics • Strain Gauge, ROUT≈ 5kΩ, 0-300mm Hg Range, FSOUT= 300mV, BW = 5Hz Analog Frontend Requirements • Low noise and gain signal conditioning. Low noise at low frequency, high DC accuracy, low power vs. low noise • ISL28217 or ISL28233 for low noise, high voltage for gain amplification (10x to 20x) • Active Filters. Low pass filters for cuff pressure. Bandpass filters to capture oscillations, ISL28217 or ISL28233, use INTERSIL’S FILTER DESIGNER. • See Intersil’s Medical Brochure for other analog components. http://www.intersil.com/literature/images/LC-097.pdf Power • For portable monitors, efficiency and size are the main focus. • ISL9440A, ISL9104, ISL8033 are some of the products that can power the FPGA and also work well to generate the power to the amplifiers in the system. • http://web.transim.com/iSimFilter/Pages/DesignReq.aspx

  7. SpO2 – Pulse Oximetry(saturation oxygen in blood) Pulse Oximetry Basics • Pulse Oximetry is the non-invasive measurement of the arterial blood’s oxygen saturation. • Detectors are needed to determine deoxygenated vs. oxygenated blood. Analog Frontend Requirements • Diagnostic SpO2 typically uses JFET-input op amps, or CMOS op amps are used to construct the transimpedance amplifier frontends. • The ISL28110/210 is a precision JFET-input op amp that can be used for these applications because of its low noise and high impedance. Power • The majority of these oximetry monitors are portable and run from 1 or 2 cell Li-ion batteries. These are rechargeable devices. • The ISL9220A can be used in these applications to recharge at higher efficiency with up to 2A charge current. • The ISL9104 fully integrated 500mA Switching regulator can be used to generate a very compact switching solution because of its high switching frequency.

  8. Body Temperature Temperature Sensor Basics • Type varies for surgical, patient-care, home care. Typically either infrared, thermistor, or thermopile/ pyroelectric sensors. • System consists of a small sensor voltage, then gain and filter signal conditioning. Analog Frontend Requirements • Diagnostic (professional) vs. home use (ear-type) vary. For diagnostic body temp monitors, use precision op amps for signal conditioning. • Intersil provides several options for high DC precision, low temperature offset drift and lower power : • For IR sensors: ISL28130 Low Cost, Low Power • For Thermistor: ISL28217, ISL28207, ISL28218 for precision • For Pyroelectric/Thermopile: ISL28110, ISL28133, ISL28217 Power • Making the power solution compact with a reduced BOM is critical. • The low current switching regulators and multi- output low current LDO’s are a good fit for power here. ISL3232 ISL4221E

  9. Product Specifics

  10. ISL28110/210: JFET-Input, Low Noise Op Amps • Outstanding Noise Performance • Low Bias Current of TIA Applications • High Impedance Buffers

  11. Precision Low Noise JFET Operational Amplifier . • ISL28110/210 Superior Low IBIAS • and • Noise Performance Competitive Summary Medical Applications Pulse Oximetry ECG/EEG In Vitro – Biochemical Analyzers Anesthesia Equipment Blood Flow Measurement 10x Better 300 fATypical

  12. ISL28130/230/430: 1.65V to 6V Micropower Rail-Rail, Precision Amps • Ear Thermometer Temperature • Lowest Operating Voltages 0.825V 1.65V ISL28130 ISL28130 - 0.825V

  13. ISL9440A: Triple Output PWM Controller With a Single LDO Controller Medical Applications ECG / EEG Imaging systems Patient monitoring Dialysis machines

  14. ISL9220: Switching Charger for 1 & 2 Cell Li-Ion Batteries VBAT = 3.6V VBAT = 3.0V VBAT = 4.0V

  15. ISL9305: Compact Power Management IC Reduces Complexity • Dual High Fsw Buck + Dual Low VIN LDO • 3MHz fixed switching frequency • 800 mA from the buck regulators (H version: 1500mA) • 300mA output current from the LDOs • Available in WLCSP & QFN packages • I2C interface to set voltage, set on/off sequence and En/Disable PFM mode • 15mV Pk-Pk PFM ripple • Excellent load transient response

  16. ISL9103/4: Low Power Switching Regulator • 2.5MHz/4.3MHz Synchronous Buck Regulator with up to 95% efficiency • 500mA Buck Regulator with high switching frequency and ultrasonic mode of operation • Low Quiescent current of 20µA IQ in PFM Mode • 2.7V to 6V Vin range • 3% Output Accuracy Over-Temperature and Line for Fixed Output Options • 100% Maximum Duty Cycle for Lowest Dropout • Discharge Output Capacitor when Disabled • Tiny 1.6x1.6mm Package Tiny 1µH inductor

  17. Closing