Patient monitoring and Diagnostic Equipment Solutions. Medical Solutions. Introduction Purpose Introduce Intersil solutions for patient monitors and medical diagnostic equipment Objectives Overview of several sub-blocks of the patient monitor systems and various medical diagnostic equipment
E N D
Medical Solutions • Introduction • Purpose • Introduce Intersil solutions for patient monitors and medical diagnostic equipment • Objectives • Overview of several sub-blocks of the patient monitor systems and various medical diagnostic equipment • Present Intersil feature products with select application circuits • Content • 16 pages • Learning time • 30-40 minutes (estimated)
Intersil Products Products Highlighted • Op Amps • Data Converters • Switches and Multiplexers • RS-485/422 Interfaces • Voltage references • Digital Potentiometers (DCPs) • Real Time Clocks • PWM Controllers • Integrated FET Switching Regulators • Isolated Power • Battery Chargers • Voltage monitoring Other Intersil Products • Ambient Light Sensor/Proximity Detector • LED Backlighting • Audio Amplifiers
ECG / EKG • ECG signals basics • Typically 0.05 Hz to 150 Hz bandwidth, 1mV to 10mV pp • Systems are EMI sensitive Analog Frontend Requirements • Low noise at low frequency, high impedance (low leakage) components are required • ISL28110 for low noise, high impedance body probe buffers • ISL28217 for right leg drivers • Other analog components: • ISL54500 for lead switching • ISL21009D for low power VREFs • Accuracy depends on AC or DC coupling approach from 10-bit to 16-bit. • Power • Multi output voltage solutions for powering processors or FPGA • ISL9440A triple output controller and single LDO controller generates the rails for a FPGA. • ISL80101 LDO family can reduce EMI in noise sensitive areas.
Blood Pressure (NiBP)- Non-Invasive Blood Pressure Pressure Sensor Basics • Strain Gauge, ROUT≈ 5kΩ, 0-300mm Hg Range, FSOUT= 300mV, BW = 5Hz Analog Frontend Requirements • Low noise and gain signal conditioning. Low noise at low frequency, high DC accuracy, low power vs. low noise • ISL28217 or ISL28233 for low noise, high voltage for gain amplification (10x to 20x) • Active Filters. Low pass filters for cuff pressure. Bandpass filters to capture oscillations, ISL28217 or ISL28233, use INTERSIL’S FILTER DESIGNER. • See Intersil’s Medical Brochure for other analog components. http://www.intersil.com/literature/images/LC-097.pdf Power • For portable monitors, efficiency and size are the main focus. • ISL9440A, ISL9104, ISL8033 are some of the products that can power the FPGA and also work well to generate the power to the amplifiers in the system. • http://web.transim.com/iSimFilter/Pages/DesignReq.aspx
SpO2 – Pulse Oximetry(saturation oxygen in blood) Pulse Oximetry Basics • Pulse Oximetry is the non-invasive measurement of the arterial blood’s oxygen saturation. • Detectors are needed to determine deoxygenated vs. oxygenated blood. Analog Frontend Requirements • Diagnostic SpO2 typically uses JFET-input op amps, or CMOS op amps are used to construct the transimpedance amplifier frontends. • The ISL28110/210 is a precision JFET-input op amp that can be used for these applications because of its low noise and high impedance. Power • The majority of these oximetry monitors are portable and run from 1 or 2 cell Li-ion batteries. These are rechargeable devices. • The ISL9220A can be used in these applications to recharge at higher efficiency with up to 2A charge current. • The ISL9104 fully integrated 500mA Switching regulator can be used to generate a very compact switching solution because of its high switching frequency.
Body Temperature Temperature Sensor Basics • Type varies for surgical, patient-care, home care. Typically either infrared, thermistor, or thermopile/ pyroelectric sensors. • System consists of a small sensor voltage, then gain and filter signal conditioning. Analog Frontend Requirements • Diagnostic (professional) vs. home use (ear-type) vary. For diagnostic body temp monitors, use precision op amps for signal conditioning. • Intersil provides several options for high DC precision, low temperature offset drift and lower power : • For IR sensors: ISL28130 Low Cost, Low Power • For Thermistor: ISL28217, ISL28207, ISL28218 for precision • For Pyroelectric/Thermopile: ISL28110, ISL28133, ISL28217 Power • Making the power solution compact with a reduced BOM is critical. • The low current switching regulators and multi- output low current LDO’s are a good fit for power here. ISL3232 ISL4221E
ISL28110/210: JFET-Input, Low Noise Op Amps • Outstanding Noise Performance • Low Bias Current of TIA Applications • High Impedance Buffers
Precision Low Noise JFET Operational Amplifier . • ISL28110/210 Superior Low IBIAS • and • Noise Performance Competitive Summary Medical Applications Pulse Oximetry ECG/EEG In Vitro – Biochemical Analyzers Anesthesia Equipment Blood Flow Measurement 10x Better 300 fATypical
ISL28130/230/430: 1.65V to 6V Micropower Rail-Rail, Precision Amps • Ear Thermometer Temperature • Lowest Operating Voltages 0.825V 1.65V ISL28130 ISL28130 - 0.825V
ISL9440A: Triple Output PWM Controller With a Single LDO Controller Medical Applications ECG / EEG Imaging systems Patient monitoring Dialysis machines
ISL9220: Switching Charger for 1 & 2 Cell Li-Ion Batteries VBAT = 3.6V VBAT = 3.0V VBAT = 4.0V
ISL9305: Compact Power Management IC Reduces Complexity • Dual High Fsw Buck + Dual Low VIN LDO • 3MHz fixed switching frequency • 800 mA from the buck regulators (H version: 1500mA) • 300mA output current from the LDOs • Available in WLCSP & QFN packages • I2C interface to set voltage, set on/off sequence and En/Disable PFM mode • 15mV Pk-Pk PFM ripple • Excellent load transient response
ISL9103/4: Low Power Switching Regulator • 2.5MHz/4.3MHz Synchronous Buck Regulator with up to 95% efficiency • 500mA Buck Regulator with high switching frequency and ultrasonic mode of operation • Low Quiescent current of 20µA IQ in PFM Mode • 2.7V to 6V Vin range • 3% Output Accuracy Over-Temperature and Line for Fixed Output Options • 100% Maximum Duty Cycle for Lowest Dropout • Discharge Output Capacitor when Disabled • Tiny 1.6x1.6mm Package Tiny 1µH inductor