200 likes | 440 Views
SC9XA. WGA4-2. CLC/TS50238-2:2010. Railway applications - Compatibility between rolling stock and train detection systems Part 2: Compatibility with track circuits (pr15360) 100% positive vote received Individual results yes/no - 21/0 Publication prepared July 2010
E N D
SC9XA WGA4-2 M Petkova
CLC/TS50238-2:2010 • Railway applications - Compatibility between rolling stock and train detection systems Part 2: Compatibility with track circuits (pr15360) • 100% positive vote received • Individual results yes/no - 21/0 • Publication prepared July 2010 • All editorial comments addressed Convenor of WGA4-2 M Petkova
CLC/TS50238-3:2010 • Railway applications - Compatibility between rolling stock and train detection systems Part 2: Compatibility with axle counters (pr21550) • 96% weighted positive vote received • Individual results yes/no - 20/1 • Publication prepared July 2010 • All editorial comments addressed Convenor of WGA4-2 M Petkova
Definition of susceptibility limits of axle counters Convenor of WGA4-2 M Petkova
Standard co-ordinates Convenor of WGA4-2 M Petkova
FM – x direction Convenor of WGA4-2 M Petkova
FM – y direction Convenor of WGA4-2 M Petkova
FM – z direction Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 1 Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 2 Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 3 Convenor of WGA4-2 M Petkova
Pr16623 Basic parameters for train detection systems to allow safe detection of RST • Resolution 34/1 • Noting BT decision D136/033 to set back project 16623 to PWI stage, SC9XA resolves to initiate a survey group within WGA4-2 with the remit of identifying the characteristics of train detection that need to be defined, with the objective of initiating a New Work Item Proposal. Convenor of WGA4-2 M Petkova
Report from the survey group/WGA4-2 • Progress to date • 28 September – 1st meeting of WGA4-2 • Decision taken to continue work in two subgroups focused on track circuits and axle counters, correspondingly • 10 November – 1st meeting of TC survey group • 11 November – 1st meeting of AxC survey group • 2 parameters list developed accordingly and responsibility for managing assigned • Additional responsibility identified for IM for maintaining parameters in the framework of interoperability Convenor of WGA4-2 M Petkova
Way forward • SC9XA issues the report of the survey group to all National Committees for 2 month enquiry to finalise the new mandate for WGA4-2. • WGA4-2 starts work immediately, to avoid further delay to the introduction of Interoperability • WGA4-2 remains a joint WG. New members are welcome. Convenor of WGA4-2 M Petkova
Frequency management (rules for definition) CCS TSI – interface Doc RST AxC (or TC, or other) Design guideline Design target TSI Implementation timeframe • X years • X years Basic parameters for target system { • TS50238 (Appendix C) • TS50238 - matured • Compatibility with other/old vehicles + + + Convenor of WGA4-2 M Petkova
16.7 Hz traction – next step for FM • All Track Circuits currently listed as preferred can be taken into account for the FM. • - Austria – S50108914 106,7 Hz; S1722-8 100 Hz • - Germany – FTGS 46, FTGS 917 • - Netherlands – FTGS 46, FTGS 917, HVI • - Norway – FTGS 46, FTGS 917, 95 Hz, 105 Hz • - Sweden – JRK10470 • Switzerland – UGSK 95, UGSK 3, FTGS 46, FTGS 917 • Note: TI21 listed as preferred in TS50238-2 but since dropped from the list by the Norwegian National Rail Administration Convenor of WGA4-2 M Petkova
DC Traction • Proposed steps to achieve f-management • 750 V DC special case • 1 500 V DC and 3 000 V – f management to be merged if possible, as in the Energy TSI, across the f-range • Audio F track circuits –1.6 – 7kHz Convenor of WGA4-2 M Petkova
50Hz traction – proposed steps to achieve f-management • 50 Hz traction • LF area • Single f + 75/275 Hz – special case • Coded track circuits • Audio F track circuits –1.6 – 7kHz • Higher F management – 50-70kHz Convenor of WGA4-2 M Petkova
List of preferred track circuits for 50 Hz traction (TS50238-2) • - Belgium – Jade 2, HVI TC • - Czech Republic – EVKO 275 Hz, KOA 75 Hz, KOA 275 Hz, ASE, ASAR • - Denmark – DC TC, 77 Hz, FTGS 46, FTGS 917 • - France – UM71 C*, UM71 CB*, UM71 CTVM*, HVI, SJB* • - Italy – ATIS (CBDAC), Digicode DTC24-2 • - Poland – SOT-1, SOT-2, EON-1, EON-3, EON-6 • - Netherlands – Jade 1-28, Jade 1-31, Jade 1-49, Jade 1-67, Jade 2, HVI • - UK – EBI Track 200 (TI21), DC AC immune various, UM71 C TVM SEI • - Spain – FS3000 Convenor of WGA4-2 M Petkova
Q&A • Thank you for your attention Convenor of WGA4-2 M Petkova