1 / 23

SUN StorEdge Library Installation & Operating Manual(Quantum OEM)

SUN StorEdge Library Installation & Operating Manual(Quantum OEM). Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd. OEM of Quantum M1500 Supported Drive Type SCSI-LVD : SDLT320, LTO Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1

tao
Download Presentation

SUN StorEdge Library Installation & Operating Manual(Quantum OEM)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd

  2. OEM of Quantum M1500 Supported Drive Type SCSI-LVD : SDLT320, LTO Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal Bridge(FC420) or External Bridge Not Support Mixed Drive Max # of Cartridge Slot 21 DLT or 25 LTO slots Max Capacity : 5 TB Max # of Drives : 2 (All Type) Barcode Label : Included Mix & Match L25 with L100 Libraries Up to 14 Drive & 175 slots when scaled to seven modules 4u rack height Hot swappable tape drives & power supplies Standard redundant power supplies 250,000 hours MTBF Front View SUN StorEdge L25 Tape Library 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  3. OEM of Quantum M2500 Supported Drive Type SCSI-LVD : SDLT320, LTO Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal Bridge(FC420) or External Bridge Not Support Mixed Drive Max # of Cartridge Slot 84 DLT or 100 LTO slots Max Capacity : 20 TB Max # of Drives : 6 (All Type) Barcode Label : Included Mix & Match L25 with L100 Libraries Standalone & Rackmount Configurations Hot swappable tape drives & power supplies Standard redundant power supplies 250,000 hours MTBF Front View SUN StorEdge L100 Tape Library 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  4. Hardware 구성도 Terminator X6758A(Ultra3 HBA) 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  5. Library SetupOrder • 1. Host에 Scsi Cable연결& Library Power On (11번 Slide참조) • 2. Library Inventory 종료 후 Media Import (11번 Slide 참조) • 3. OS상에서의 St Driver & Ultra3 Patch확인, Patch(6번Slide 참조) 4. Tape Device생성 • 가. OK mode : OK> boot –r • 나. MultiUser Mode : # reboot -- -r or #drvconfig;tapes;(Online Rebuild) • 5. OS상에서의 Device생성 확인 • 가. #luxadm inq /dev/rmt/테잎순서or • # /dev/rmt/밑에 device생성되었는지 확인 • 나. Netbackup or NetWorker상에서 changer & tape확인 #sgscan –v changer;sgscan –v tape (Netbackup Utility) #inquire (Networker Utility) 6. Robot Test 가. #/usr/openv/volmgr/bin/robtest로 미디어 제어확인 ex) init , test_ready etc … 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  6. ST Driver Patch Required • Scsi Type에 맞는 HBA Card장착 • Ultra3 SCSI(LVD) 160m/s : X6758A • Ultra2 SCSI(LVD) 80m/s : X2222A • Ultra Differential(HVD) 40m/s : X6541A • Ultra Differential Fast/Wide(HVD) 40m/s : X6749A(EOL) • Device Server쪽에 current version st.conf 등록 • Version별 Patch Name • Solaris 2.6 : 105847 • Solaris 7 : 107460 • Solaris 8 : 108725 • Solaris 9 : 13277 • LVD tape drive는 Solaris 7, 이하 버전 지원못함 • Device Server쪽에 Ultra3 patch(Ultra 3 Scsi일 경우) • SUNWqus.tar.Z [66K] SUNWqusx.tar.Z [68K] • SUNWqusu.tar.z [3K] SUNWqusux.tar.Z [4K] 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  7. Performance Tunning • HBA의 최대 속도와 Library의 속도 확인 • X6758A(Ultra3 SCSI)의 경우 HBA속도 : 160m/s(Dual Port), 한 개 Port는 Maximun 80m/s지원 • LTO2 Drive(초당 30m/s)지원 • L8 Library의 경우 Robot과 Drive가 같은 Port를 사용하므로 X6758 한 개 Port만으로도 드라이브 속도를 충분히 소화할수 있음 • Drive가 여러 개인 경우 / Robot Scsi Port가 분리된 경우(L25/L100/L180) • HBA의 한 개 Port의 Maximun Speed와 드라이브 속도 체크 • Ex) Drive가 3개인 경우 • Library쪽 port는 Maximum 4ea(Robot 1ea / Drive 3ea) • Robot 3ea를 Jumping할 경우 90m/s를 지원해야 함 • 따라서 X6758의 경우 80m/s밖에 지원이 안되므로 나머지 port를 사용하여 Library쪽에서두개의 Line을 사용하는 것이 바람직함 • (Robot+Drive1ea = 1개 channel / Drvie2ea = 1개 channel) • Robot에 연결된 Scsi Fail시 Drive작동이 전혀 불가하므로 가능하면 Redundancy차원의 Scsi Cable을 분리하여 잉여 드라이브를 사용 권장 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  8. Connect Library to the HOST • Cabling Diagram • Single SCSI BUS • HBA Card의 속도가 Drive 2ea를 지원하고 한 개 Port만 사용시 • Two SCSI BUS • 분리된 HBA Card or Port를 사용하여 속도 & Redundancy 고려 • Three SCSI BUS • Drive, Robot을 전부 분리, HBA Card or Port를 사용하여 속도 & Redundancy 고려 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  9. L100 Recommended Cabling • Cabling Diagram X6758A 3개 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  10. Hardware Installing Order • Drive Installing • Tape Labeling • Unpacking L25 Base / Drive / Tape • HVD / LVD Type 고려하여 Drive installing(Max 2ea) • Tape Barcode Labeling • 쓰기방지탭 조정 • Left : Enabled • Right : Write-Protected • 필요시 Management Card 추가 장착 • Write Protect Switch Setup 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  11. Hardware Installing Order • Remove magazine & Inserting Tapes • L25 PowerOff시 : 펜을 이용하여 release button을 누른후에 Magazine 분리 • Power On시 : LCD Pannel Key조작을 이용하여 Main-Mags-Release 사용 • Labeling된 Tape을 Magazine에 삽입한다(상하주의, 강제삽입 금지) • Tape 분리시 : Cartridge retaining latch를 누른 상태에서 분리 • Cleaning Tape : L25 Magazine 빼낸 후 안쪽의 Fixed Slot에 직접 삽입 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  12. Powering Up the Library • Connect L25 Library to AC Power • Power ON • Initializing을 통해 자동 inventory및 Self Test실행 • 완료시 GUI에 Drive / Slot별 Media Status 출력 • 각 GUI Screen의 하단에 5개 Button label로 조작 • Library run Post-On-Self-Test(POST) 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  13. Disabling Unused Drive Bays • Using the GUI Buttons • 사용하지 않는 Drive Bay Setup • Main GUI -> Press Menu -> Press Config • Unused drive bay에 highlight될때까지 up, down key로 조작후 Press Select • Press Down Button Until Disabled • Setup완료후 main screen으로 돌아가지 않으면 NVRM에 저장되지 않는다 • Setting이 제대로 인식되기 위해 반드시 Library를 Reboot한다 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  14. Library Features • Front Panel • Graphical User Interface(GUI) • 라이브러리 상태 정보, 라이브러리 메뉴를 액세스 할수있게 해줌 • Library Setting값의 View & Change, daemonstration programs의 구동, diagnostic tests • Magazine door buttons • Mags option을 사용하여 Unlocked magazine을 열때, Power-Off & magazine Open시 사용 • Light Emitting Diode(LED) • Green LED : 호스트 채널로부터 액세스 가능하도록 Full Operational & Ready상태 • Green LED Flash : Ready상태에서 NOT Ready상태로 변환되는중 • Power-On-Self-Test시 • Magazine Release상태일 경우 • 특정 menu Item access시 • Red LED : Library Error 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  15. Library Features • Back Pannel • Internal Layout 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  16. GUI Icon Status • Writing Data • Power On • Drive Fault • Tape Is Write-Protected • Drive Need Cleaning • Slot Empty • Solt Occupied • Slot Occupied – no Label or Bad barcode • No tape present • Tape Loading • Tape Unloading • Tape Unloaded • Tape Idle • Tape Rewinding • Location Data • Reading Data 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  17. Library & Drive & Inventory Info. • Main GUI -> Press Quick View -> Press Library or Drive or Inventory • Modelaud / Code Revision, Scsi ID 기타 정보 확인 • Library가 L100이상이거나 Stack Link인 경우는 Level button을 이용하여 각단계별 Inventory확인 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  18. Release Magazine & Drive Power • Magazine을 분리하기 위해 Library On 상태에서 실행 • Main GUI -> Press Mags -> Release Magazine창에서 • Left / Right / Both중 Open시킬 Magazine 선택, select • 전면 Magazine door button누른 후 Magazine 분리, 작업 • 완료후 Re-Lock • Main GUI -> Press Quick View -> Drv Pwr • Power-On, Off시킬 Drive Select • 해당 Drive highlishted되면 Up, Down button으로 현재 Setting 변경 • Tape Drive Hot-Swapping에 주로 사용 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  19. Moving Tape Cartridges • Main GUI -> Press Menu -> Press Move -> Move Cartridge FROM • Up, Down키로 이동시킬 미디어를 선택한후 Select Key Press • ->Move Cartridge TO에서 이동시킬 Slot or Drive에 커서 위치시키고 Select • ->Confirm Move Cartridge로 최종 확인 • 완료시 : Moving Cartridge…. Please Wait 출력후 Move Cartridge FROM GUI Displayed again • Press Back button • Press Main button 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  20. Scsi History & Library Statistics • Main GUI -> Press Menu-> Press Service -> Press Stats • -> Library or Drive or Scsi History중 택 1 • 날짜 또는 시간별 SCSI Bus Command history상태 / Library, Drive Detail Statistics 확인 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  21. Changing the Library Configuration • Changing the Baud Rate Setting • Serial Diagnostics port 접속을 위한 baud rate Control • Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select baud rate -> Press Select -> up & Down, select desired Baud Rate • Setting the Time & Date • Library Time & date 설정 • Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Time or Date -> Press Select -> up & Down, select correct date, time • Changing the AUTO-Clean Setting • Default Setting -> Disabled, Hardware적으로 적정 시점에 Cleaning할수 있도록 Setup(권장) / Backup S/W의 clean setup 사용시보다 관리 용이 • Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Auto-Clean -> Press Select -> up & Down, select Enabled 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  22. Performing Maintenance Operations • Cleaning a Tape Drive • Adjusting the Contrast • 수동 Cleaning 시 사용 • Main GUI -> Press Menu -> Press Service -> Press Maint -> Press Clean -> DisPlayed “Select Cleaning Cartridge screen” -> 클리닝 카트리지 선택 -> DisPlayed “Select Tape Drvie” -> 클리닝할 드라이브 선택 • Main GUI -> Press Menu -> Press Service -> Press Maint -> Press Contrast • 원하는 Contrast까지 Increase or Decrease Button Press 2004 Loit Co., Ltd Storage Business Dept. 1 Team

  23. Related Documentation • Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library Installation Guide - Explains how to install a stand-alone Sun StorEdge L25 Tape Library or Sun StorEdge L100 Tape Library • Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User's Guide - Describes the Sun StorEdge L25 Tape Library and the Sun StorEdge L100 Tape Library and their use. • H/W장애시 LCD에 출력되는 Fault System Code(FSC) Dictionary참조, TroubleShooting Thank You! 2004 Loit Co., Ltd Storage Business Dept. 1 Team

More Related