1 / 1

說明 :2013 年 7 月份 PPM:26 0 , 判退 : 7 件 . 分析如下 :

二電廠 7 月 OQA DPPM 報告. 說明 :2013 年 7 月份 PPM:26 0 , 判退 : 7 件 . 分析如下 : 1. 標簽貼 錯 : 2 件 ( 貼歪 :1 件 , 漏貼 : 1 件 ) 對策 : 使用標簽治具 , 要求作業員重點檢查 2 . 輸入座漏鎖螺絲 :1 件 對策 : 因 返 修 漏鎖 造 成 , 返修品 更需重點檢查 3. 把手歪斜 / LED 浮高 : 1 件 對策 : 因多臺單體碰撞所致, 規定在作業中 避免單體碰撞

tarak
Download Presentation

說明 :2013 年 7 月份 PPM:26 0 , 判退 : 7 件 . 分析如下 :

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 二電廠7月 OQA DPPM報告 說明:2013年7月份PPM:260,判退:7件.分析如下: 1.標簽貼錯:2件(貼歪:1件,漏貼:1件) 對策:使用標簽治具,要求作業員重點檢查 2.輸入座漏鎖螺絲 :1件 對策:因返修漏鎖造成,返修品更需重點檢查 3.把手歪斜/ LED 浮高 :1件 對策:因多臺單體碰撞所致,規定在作業中避免單體碰撞 4.燒錄Connector PIN 沾膠:1件 對策:因點膠過量所致,控制制程合理膠量 5.單體高度超過限高:1件 對策:因量高治具尺寸錯誤所致,IE要重點CHECK治具各個尺寸 6.線材脫 PIN, P7 線材破損:1件對策:因作業方法不正確所致,培訓員工正確作業工法