An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CCR Payload for the Astrobotic Lander 30 March 2011 --------------------------------------------Kris Zacny, PhDVice PresidentDirector, Technology Exploration GroupHoneybee Robotics Spacecraft Mechanisms Corporation 398 W Washington Blvd., Suite 200, Pasadena, CA 91103ph: 626-389-8459 / fax: 626-689-4823 / mob: 510-207-4555 / blackberry: 646-508-9807 zacny@honeybeerobotics.comhttp:/www.honeybeerobotics.com

  2. CCR System CCR Deployment Mechanism

  3. CCR Deployment Mechanism in stowed position Pin Puller #1 is actuated, releasing the spring loaded linear stage Linear stage is on rollers for smooth deployment CCR Deployment Sequence [1] 1 Rover track and landing thrusters hidden for clarity

  4. CCR Deployment Sequence [2] • Linear stage reaches end of travel • Roller (1) constraining CCR is free, due to slot in roller track (2) • Preloaded, redundant torsion springs (3) cause CCR rod to pivot upwards 3 1 2

  5. CCR Deployment Sequence [3] • Pivot Assembly reaches hard stop. Limit switch is triggered • Pin Puller #2 is actuated, releasing the CCR Rod 2

  6. 2 3 1 4 CCR Deployment Sequence [4] • Nose Cone (3) contacts ground • Puncture Rod (2) is pushed upwards. Tip punctures sealed gas cylinder (1) • Gas is released from gas cylinder, exiting out the nose cone jets (4) • CCR Rod plunges into the soil CCR Rod is free to slide within the sleeve

  7. CCR Deployment Sequence [5] • (Left) Non-contact position sensor is triggered at end of travel • (Center) Pin Puller #3 is actuated, releasing spring loaded arms simultaneously • (Right) CCR Rod continues to plunge into soil unhindered 3 3

  8. CCR Deployed [1]

  9. CCR Deployed [2] ~39”