1 / 13

Design of Mockup Detector

Design of Mockup Detector. 박강순 ( 서울대 ) for RENO Collaboration. Outline RENO Detector (Neutrino Detector) Design of Mockup Detector PMT Source Driving System Summary. Korean Physical Society Meeting 08/4/17. RENO Detector. 진입 로. RENO Experimental Hall.

Download Presentation

Design of Mockup Detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of Mockup Detector 박강순 (서울대) for RENO Collaboration • Outline • RENO Detector (Neutrino Detector) • Design of Mockup Detector • PMT • Source Driving System • Summary Korean Physical Society Meeting 08/4/17

  2. RENO Detector 진입 로 RENO Experimental Hall 동일한 검출기 2기(근거리,원거리) 제작

  3. RENO Detector RENO Detector (Neutrino Detector) Dimensions • 10” PMT 354개 장착 • 현재 디자인 작업 진행 중 • 2008년 말 제작 시작

  4. Design of Mockup Detector • 대형 RENO 검출기 제작에 앞서 약 20배 축소된(체적대비) 소형 검출기(mockup detector) 제작 •  RENO 검출기의 디자인을 기본 •  아크릴 용기 제작 및 long term stability 와 light transmittance 테스트 •  방사능 소스를 이용한 calibration system 테스트 •  Light calibration system 테스트 •  Mineral Oil (buffer tank)에서의 PMT performance 테스트 •  LS (Liquid Scintillator) handling system 테스트 • 2008년 5월 말 ~ 6월 초 검출기 조립완료 •  약 90%의 제작 주문 완료

  5. Design of Mockup Detector (MC Simulation) Top view • 32 개의 10인치 PMT(Hamamatsu) 사용 (top/bottom 6/7, side 18) - surface coverage 10% • Target radius variation: - 10, 20, 30cm • Catcher thickness variation: - 40, 50, 60, 70cm • Buffer thickness • Source 를 사용하는 경우 가능하면 두께가 얇을수록 좋음. • 10인치 PMT의 크기(31cm)를 고려해서 40cm가 적당. Side view Mockup simulation (Geant4)

  6. Design of Mockup Detector (MC Simulation) Energy spectrums in MC simulation of Mockup Detector 137Cs 60Co # of photoelectron # of photoelectron

  7. Design of Mockup Detector

  8. Design of Mockup Detector (Target & Gamma Catcher) Source calibration 용 chimney(TPFE convoluted tube) • 캐스팅 아크릴 GS233 (Plexiglas사) •  내화학성 및 내구성 이 높음 • 투과율 ~92% • Target(tube)은 Reynolds사(미국)로부터 공수 • 대형 수족관 제작 업체인 코아테크㈜ 에서 제작 (5월 초 완성) Gamma Catcher Target

  9. Design of Mockup Detector (Buffer tank) Glove box • Stainless 304 (4T/5T) • 거산 에스이㈜ 에서 제작 Sliding gate Source chimney PMT 고정용 버플 (stainless) Buffer tank Top view

  10. Mockup Gallery

  11. Design of Mockup Detector (PMT & Stainless Holder) PMT holder • Hamamatsu 10 인치 PMT • single cable (HV + signal) • 5월 말 도착 예정 • Stainless PMT holder 제작 • 부력에 의한 stress 테스트 KAMLAND RENO

  12. Design of Mockup Detector (Source Driving System) Glove box (air sealed) 사용 될 방사능 소스

  13. Summary & Plan • Mockup Detector 제작 단계 •  아크릴 용기, 스테인리스 탱크, PMT, LS 등 제작 진행 중 •  5월말 ~ 6월초 assembly 완료 •  6월 중순 data taking • RENO Detector 제작 •  11,12월 디자인 완료 및 제작 주문 •  2009년 초 assembly

More Related