140 likes | 154 Views
FIDEGAS. Gas detection systems. FIDEGAS CA. presentation. Control unit for the detection of toxic and explosive gases provided with standard 4-20mA input for 2, 4 & 8 detectors. Exclusively developed to be installed with FIDEGAS S/3 (EEx d II C T6) detectors.
E N D
FIDEGAS Gas detection systems
FIDEGAS CA presentation Control unit for the detection of toxic and explosive gases provided with standard 4-20mA input for 2, 4 & 8 detectors. Exclusively developed to be installed with FIDEGAS S/3 (EEx d II C T6) detectors. Cover (keypad) in English & Spanish • FIDEGAS CA is provided of: • 2 actuation levels: Prealarm and Alarm • Available outputs at 12V DC, 230V AC & D.C. • Alarm & cabling fault indicators • LEDs: prealarm, alarm, fault, 100% L.E.L., auxiliary battery • Events memory Connection cable: Halogen free shield cable with 1mm2 section for a maximum length of 250 m. Control unit & detector EARTH connected ATEX certificate issued by Madariaga Official Laboratory LOM 03ATEX2095 when FIDEGAS S/3 detectors are connected.
FIDEGAS S/3. Exproof detectors available gases FIDEGAS S/3-2 Explosives FIDEGAS S/3 T1 & T2 Toxics For other gases, consult EEx d II C T6
1 Check the correct functioning of the detector with testing gas every 6 months 1 2 Recalibrate FIDEGAS S/3 detector every 2 years during its working life (at manufacturer´s factory) Each filter/sensor has its own electronic circuits Do not swap sensors or circuits. FIDEGAS S/3. Exproof detectors maintenance
Release the cables from the connector marked with 1, 2, 3, & Earth connection. • Releasing the self-blocking take out the whole set (cable + connector/s). • 2. Release sensor´s connector. • 3. Unscrew the filter/sensor. • Do not twist the flat cable, neither hook it with other elements. • 4. Electronic circuit can be dissassembled after releasing 2 subjection screws. FIDEGAS S/3. Exproof detectors maintenance Dissassemble and replacement of FIDEGAS S/3 detector Each filter/sensor has its own electronic circuit Do not swap sensors or circuits.
FIDEGAS CA Quick installation guide
2. Control unit´s bag includes the following replacements: 2 1Afuses Thermal retractable tubeto isolate the detector-panel shield connection cable avoiding short-circuits Conectors It allows the correct functioning of the panel when one or more are not connected (or if they has been disconnected for revisions). Screw M-4. Electronic circuit FIDEGAS CA Quick installation guide 1. Mount on the wall the control unit (door to be opened from left to right). 3. Control unit – detector connection Fuse 1A. Protect the detectors. All fault LEDs lightining up mean blowed fuse Connect: control unit-detector Isolate the shield using the thermal retractable tube and connect it to EARTH in the proper connector. Place the connector in those non used connectors
Between C & NO (ALARM) Between C & NC (GAS CUT) PREALARM: This output its timed to activate the extraction during 2 minutes. IT SHOULD NOT ACTIVATE ALARMS 12V CC Outputs Do the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 2V and total consumption does not exceed the C fuse value of 0,5A. FIDEGAS CA2. Conector 230V AC Dry contact (close contact and no powered). Between C & NC (ALARM) Between C & NO (GAS CUT) Example of 12V output connection to an electrovalve FIDEGAS CA2.Conector 12V DC FIDEGAS CA Quick installation guide 230V CAOutputs Do the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 230V and total consumption does not exceed the B fuse value of 2A. CONSIDERATIONS: When connecting 230V -or after a main fault- wait for 30 s before REARMING the system.Pay attention to the fuses capacity (mentioned in the manual)When all fault LEDs will be lightining up, check the state of the fuse ( D - E )
Testing bottle concentration is not suitable for calibration neither precision test. Ii is only recommended to check the detectors correct functioning. FIDEGAS CA Quick installation guide FIDEGAS S/3 DETECTORS testing: Put the cap on the sensor head 1 Introduce cannula In the cap´s hole 2 Release gas for 2 s. to activate alarm Wait 3 s before releasing more gas as required gas concentration to activate the ALARM keeps 2 m in the mask aprox.. 3
FIDEGASC presentation Control unit for the detection of toxic and explosive gases for 2, 6 & 12 detectors. Exclusively developed for FIDEGAS S/10 detectors. Cover (keypad) in English & Spanish • FIDEGAS C is provided with: • 2 actuation levels: Prealarm & Alarm • Available outputs at 12V DC & 230V AC • LEDs: Power, prealarm, alarm, output • Rearm push button • Prealarm Output • FIDEGAS S/10 detector • Power supply: 12V DC • Consumption: 120 mA • Type of sensor: Catalytic • Useful life: 5 years • Coverage area: 15 m2 • Available for: Natural gas (Methane), Butane-Propane • Measurement range: From 0 to 100% L.E.L. • Protection Grade: IP 435
FIDEGAS C30 presentation Stand-alone EXPROOF detector(EExd II C T6)for explosive gases (Natural gas-Methane-, Butane-Propane, Hydrogen) provided with a relay output for acting when gas presence reaches a level equal or higher than 20% Low Explosive Limit (L.E.L.). Available at 12V or 24V. Coverage area: 16 m2 aprox.
FIDEGAS S/10 stand-alone presentation Stand-alone detector for explosive gases (Natural gas-Methane-, Butane-Propane,) provided with a relay output for acting when gas presence reaches a level equal or higher than 20% Low Explosive Limit (L.E.L.). Available at 12V or 24V. Coverage area: 16 m2 aprox. Use shield cable 4 x 0,25 mm2 maximum length 300m (4 x 0.50 mm2 – 600 m).
applications FIDEGAS CA Batteries rooms Cellars Chemical industry Chicken farms Nuclear industry Refrigeration Fertiliser plants Fumigation Grain storage Greenhouses Laboratories Paper mills Water treatment Steel works Swimming pools Food processing applications FIDEGAS C Boiler rooms Kitchens Laboratories