An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Kansas State University Department of Physics Diagnosis of a High Harmonic Beam Using COLTRIMS Predrag Ranitović April 2005

  2. Outline 1. Motivation Time resolved photoelectron spectroscopy Development of an apparatus for performing pump-probe experiments

  3. Generation and Characterization of a High Harmonic Beam 1. Pump and Probe Arrangement using Visible-Pump and an x-ray as a probe pulse 2. Development of an apparatus for performing pump-probe experiments

  4. Outline 1. Motivation Time resolved photoelectron spectroscopy Development of an apparatus for performing pump-probe experiments Development of an apparatus for performing pump-probe experiments Generation and Characterization of a High Harmonic Beam 2. Summary and Outlook

  5. Spectrometer Aluminum filter High Harmonic Generation gas cell f=30 cm Experimental Setup

  6. + High Harmonic Generation

  7. + High Harmonic Generation

  8. + High Harmonic Generation Gas Tube Argon gas as a harmonic generation medium Harmonics’ intensity varies with the lasers’ focusing point Al filter Aluminum absorber  = 800 nm   40 fs,

  9. High Harmonic Generation Aluminum absorber

  10. High Harmonic Generation Spectrometer Aluminum filter

  11. COLTRIMS

  12. COLTRIMS – Momentum Imaging Technique Mono energetic electron with the momentum along the spectrometer electric field

  13. + Ar time of flight and detector image y [mm/2] t [ns] x [mm/2]

  14. Electron time of flight and detector image B = 12 Gauss y [mm/2] t [ns] x [mm/2]

  15. Electron time of flight and detector image Electron time of flight and detector image B = 8 Gauss y [mm/2] t [ns] x [mm/2]

  16. Electron time of flight and detector image Electron time of flight and detector image B = 6 Gauss y [mm/2] t [ns] x [mm/2]

  17. The Wiggles r [mm/2] r [m] t [ns] t [s] T=357.4/B [ns]

  18. Momentum Imaging P y P [a.u.] P [a.u.] x z

  19. Momentum Imaging B = 6 Gauss P P x y P [a.u.] P [a.u.] z z

  20. Momentum Imaging B = 8 Gauss P x P [a.u.] t [ns] z

  21. Photoelectron energies = E [eV]

  22. Photoelectron energies P x P [a.u.] z E [eV]

  23. Summary and Outlook X-ray Angular Divergence Photon flux Harmonic Orders

  24. The Wiggles

  25. Old Data

  26. + + Ar time of flight and detector image Ar time of flight and detector image This is a E  40 V/cm run, the recoil detector is still 22 cm from the interaction region

  27. Electron time of flight and detector image This is a E = 2.4 V/cm and B = 10 Gauss run, the electron detector is 5.3 cm from the interaction region

  28. Photoelectron energy (eV) Those five peaks correspond to 13th, 15th, 17th, 19th and 21st harmonic in a field free arrangement