Thermal Analysis of Al-CuO nanocomposites

Thermal Analysis of Al-CuO nanocomposites. Nancy Huemer. Two different nanocomposites were studied: Al-CuO milled with 1ml of hexane milling time 16 min. Al-CuO milled with 8ml of hexane milling time 60 min. Synthesized using ARM (arrested reactive milling).

thadeus
Download Presentation

Thermal Analysis of Al-CuO nanocomposites

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thermal Analysis of Al-CuO nanocomposites Nancy Huemer

  2. Two different nanocomposites were studied: • Al-CuO milled with 1ml of hexane milling time 16 min. • Al-CuO milled with 8ml of hexane milling time 60 min. Synthesized using ARM (arrested reactive milling)

  3. Principle and Equipment used for experiments • Differential Scanning Calorimetry Diagram of the inside of a DSC Netzsch STA 409 PC Luxx DSC

  4. Different experiments performed • Kinetics in Argon -1 ml and 8 ml samples • Kinetics in Oxygen-1 ml and 8 ml samples • Heated samples to 740º C • Heating rates used • 5, 10, 20 and 40 k/min. • Quenching • Quenched samples of 8ml at 500º and 325º C

  5. Kinetics of 1ml in Argon

  6. Kinetics of 8ml in Argon

  7. Kinetics of 1ml in Oxygen

  8. Kinetics of 8ml in Oxygen

  9. Comparison of 1ml & 8ml in Ar Heating rate , 5 K

  10. Comparison of 1ml and 8ml in O2Heating rate , 5 K

  11. Comparison of 1ml in Ar and O2Heating Rate, 5 K

  12. Comparison of 8ml in Argon and O2 Heating Rate, 5K

  13. Quenching • Quenched 8ml samples to determine the nature of the exothermic events present in the plots of 8 ml in Argon. • 325º C • 500º C

  14. Oxidation • Tests in Oxygen were performed to study the difference between this and an inert Argon environment 1ml8ml

  15. SEM Images CuO Al Al-CuO milled with 8 mL milled with 1 mL

  16. Future Studies • XRD analysis of the quenched samples • Complete oxidation samples • Quenching in Oxygen at 500º C