1 / 16

MEGA Abrasive Cutter motor and pump wiring

MEGA Abrasive Cutter motor and pump wiring. Name plate. 208Y - 230V star/delta Motor wiring. 208-230V. 380Y - 415V star/delta Motor wiring. W2,U2,V2. W6,U6,V6. 380-415V. U5, U1. V5, V1. W5, W1. 440Y - 480V star/delta Motor wiring. U2, U5. V2, V5. W2,W5. 440-480V. U1, W6. V6, W1.

thomass
Download Presentation

MEGA Abrasive Cutter motor and pump wiring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MEGA Abrasive Cuttermotor and pump wiring

  2. Name plate

  3. 208Y - 230V star/delta Motor wiring 208-230V

  4. 380Y - 415V star/delta Motor wiring W2,U2,V2 W6,U6,V6 380-415V U5, U1 V5, V1 W5, W1

  5. 440Y - 480V star/delta Motor wiring U2, U5 V2, V5 W2,W5 440-480V U1, W6 V6, W1 V1, U6

  6. Motor amps (MEGA-M250) • Maximum rated current and approximate running amps for MEGA-M250 motor is listed below • 50 Hz – 2895 rpm • 60 Hz – 3475 rpm

  7. Motor amps (MEGA-T300) • Maximum rated current and approximate running amps for MEGA-T300 motor is listed below • 50 Hz – 2880 rpm • 60 Hz – 3460 rpm

  8. Motor amps (MEGA-T400) • Maximum rated current and approximate running amps for MEGA-T400 motor is listed below • 50 Hz – 2910 rpm • 60 Hz – 3492 rpm

  9. Motor amps (MEGA-T400 – slow speed motor) • Maximum rated current and approximate running amps for MEGA-T400 motor is listed below • 50 Hz – 1455 rpm • 60 Hz – 1740 rpm

  10. Measuring amps • Using a clamp type ammeter as shown to the right, hook one of the 3-phase leads in-between the clamp Clamp around wire

  11. Pump Wiring (220/380V) 220V buss bar configuration 380V buss bar configuration

  12. Transformers Wire transformers to the correct 220 or 380V terminals

  13. Motor setting (QF-1)(MEGA-M250) Schneider GV2-ME14C/6-10A

  14. Motor setting (QF-1)(MEGA-T300) 208V Schneider GV2-ME20C/13-18A 380-480V Schneider GV2-ME14C/6-10A

  15. Motor setting (QF-1)(MEGA-T400) 208V Schneider GV2-ME21C/17-23A 380V Schneider GV2-ME20C/13-18A 480V Schneider GV2-ME16C/9-14A

  16. Pump setting (QF-2)(All Cutters) Schneider GV2-ME05C/0.63-1A