200 likes | 536 Views
www.veiki.hu. 2/20. Contents. MELCOR past experienceMELCOR transition to 1.8.6Application to VVER-440/213MELCOR Iodine Pool Model experience. . www.veiki.hu. 3/20. MELCOR Past experince. Successful application of MELCOR 1.8.3-1.8.51992- 2008SBLOCA d=40mm, d=100mm, d=500mm, d=2*500mmLoss of
E N D
1. Experience with MELCOR 1.8.5 and transition to 1.8.6 in VEIKI
1st. Meeting of the European MELCOR Users Group
Hosted by Paul Scherrer Institute
Villigen Switzerland
December 15-16, 2008
Dr. Horváth L. Gábor, VEIKI, Budapest
HorvathLG@aed.veiki.hu
2. www.veiki.hu 2/20 Contents
MELCOR past experience
MELCOR transition to 1.8.6
Application to VVER-440/213
MELCOR Iodine Pool Model experience
3. www.veiki.hu 3/20 MELCOR Past experince
Successful application of MELCOR 1.8.3-1.8.5
1992- 2008
SBLOCA d=40mm, d=100mm, d=500mm, d=2*500mm
Loss of Feed-Water
Station-Black-Out
Interface LOCA – Containment bypass
PRISE – Primary to Secondary Leakage
Cross Comparison of MELCOR-MAAP-RELAP-SCDAP
4. www.veiki.hu 4/20 MELCOR experimental verification - recalculations
Successful application of MELCOR 1.8.3-1.8.5 in VEIKI to
STORM
KAEVER
VANAM
Phebus FPT-0
Phebus FPT-1
5. www.veiki.hu 5/20 Major deficiencies of MELCOR eliminated with 1.8.6
6. www.veiki.hu 6/20 MELCOR VVER-440/213 model in 1.8.6
7. www.veiki.hu 7/20 BWR model Equivalent VVER-440 problem with fuel in bypass
8. www.veiki.hu 8/20 Melt bypass to LP
9. www.veiki.hu 9/20 Sensitivity to melt blockages at core entrance and core bypass
10. www.veiki.hu 10/20 Induced break of Hotleg Important in high pressure sequences:
Evaluated by Hotleg vs. Lower Head temperature
MELCOR 1.8.3 only 1.8.6 has to be calculated
Hotleg reaches high temperatures earlier than LH
Counter-current flow NOT investigated
11. www.veiki.hu 11/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46
12. www.veiki.hu 12/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46
13. www.veiki.hu 13/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46
14. www.veiki.hu 14/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46
15. www.veiki.hu 15/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46
16. www.veiki.hu 16/20 MELCOR 1.8.6 application: VVER-440/213
17. www.veiki.hu 17/20 MELCOR 1.8.6 application: VVER-440/213
18. www.veiki.hu 18/20 MELCOR 1.8.6 application: VVER-440/213
19. www.veiki.hu 19/20 MELCOR 1.8.6 application: VVER-440/213
20. www.veiki.hu 20/20