1 / 20

Experience with MELCOR 1.8.5 and transition to 1.8.6 in VEIKI

www.veiki.hu. 2/20. Contents. MELCOR past experienceMELCOR transition to 1.8.6Application to VVER-440/213MELCOR Iodine Pool Model experience. . www.veiki.hu. 3/20. MELCOR Past experince. Successful application of MELCOR 1.8.3-1.8.51992- 2008SBLOCA d=40mm, d=100mm, d=500mm, d=2*500mmLoss of

titus
Download Presentation

Experience with MELCOR 1.8.5 and transition to 1.8.6 in VEIKI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Experience with MELCOR 1.8.5 and transition to 1.8.6 in VEIKI 1st. Meeting of the European MELCOR Users Group Hosted by Paul Scherrer Institute Villigen Switzerland December 15-16, 2008 Dr. Horváth L. Gábor, VEIKI, Budapest HorvathLG@aed.veiki.hu

    2. www.veiki.hu 2/20 Contents MELCOR past experience MELCOR transition to 1.8.6 Application to VVER-440/213 MELCOR Iodine Pool Model experience

    3. www.veiki.hu 3/20 MELCOR Past experince Successful application of MELCOR 1.8.3-1.8.5 1992- 2008 SBLOCA d=40mm, d=100mm, d=500mm, d=2*500mm Loss of Feed-Water Station-Black-Out Interface LOCA – Containment bypass PRISE – Primary to Secondary Leakage Cross Comparison of MELCOR-MAAP-RELAP-SCDAP

    4. www.veiki.hu 4/20 MELCOR experimental verification - recalculations Successful application of MELCOR 1.8.3-1.8.5 in VEIKI to STORM KAEVER VANAM Phebus FPT-0 Phebus FPT-1

    5. www.veiki.hu 5/20 Major deficiencies of MELCOR eliminated with 1.8.6

    6. www.veiki.hu 6/20 MELCOR VVER-440/213 model in 1.8.6

    7. www.veiki.hu 7/20 BWR model Equivalent VVER-440 problem with fuel in bypass

    8. www.veiki.hu 8/20 Melt bypass to LP

    9. www.veiki.hu 9/20 Sensitivity to melt blockages at core entrance and core bypass

    10. www.veiki.hu 10/20 Induced break of Hotleg Important in high pressure sequences: Evaluated by Hotleg vs. Lower Head temperature MELCOR 1.8.3 only 1.8.6 has to be calculated Hotleg reaches high temperatures earlier than LH Counter-current flow NOT investigated

    11. www.veiki.hu 11/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46

    12. www.veiki.hu 12/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46

    13. www.veiki.hu 13/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46

    14. www.veiki.hu 14/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46

    15. www.veiki.hu 15/20 MELCOR 1.8.6 application: Phebus FPT-1, ISP-46

    16. www.veiki.hu 16/20 MELCOR 1.8.6 application: VVER-440/213

    17. www.veiki.hu 17/20 MELCOR 1.8.6 application: VVER-440/213

    18. www.veiki.hu 18/20 MELCOR 1.8.6 application: VVER-440/213

    19. www.veiki.hu 19/20 MELCOR 1.8.6 application: VVER-440/213

    20. www.veiki.hu 20/20

More Related