1 / 17

Brain segmentation and Phase unwrapping in MRI data

ECE 738 Project. Brain segmentation and Phase unwrapping in MRI data. JongHoon Lee. Outline. Nature of fast MRI: EPI & Field Inhomogeneity Background problem – Image Distortion Specific problems a) Brain Segmentation b) Phase Unwrapping Goal Approach Result

tivona
Download Presentation

Brain segmentation and Phase unwrapping in MRI data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ECE 738 Project Brain segmentation and Phase unwrapping in MRI data JongHoon Lee

  2. Outline • Nature of fast MRI: EPI & Field Inhomogeneity • Background problem – Image Distortion • Specific problems • a) Brain Segmentation • b) Phase Unwrapping • Goal • Approach • Result • Conclusion and future work

  3. Nature of fast MRI: EPI • EPI(Echo Planar Imaging) • - Most common technique for fast MRI • Magnetic Field - B(r) • - Homogeneous w/o object : B(r) = const. • - Inhomogeneous w/ object (e.g.head: bone, brain, air,…) • > Due to magnetic susceptibility difference • > EPI is sensitive to this •  Geometrical Distortion in EPI image x, y : amounts of shift (misplacement) in x, y directions in mm FOVx, FOVy : field of view in x, y direction in mm tx, ty : sampling interval in x, y direction ( 1/sampling rate)

  4. Nature of fast MRI: EPI • Geometric Distortion Example • Significance • - Misregistration of EPI and Anatomical image • Incorrect mapping of region of interest(ROI) •  Need to be corrected using Fieldmap

  5. Specific Problems • MRI data = complex image data from Fourier transform Magnitude image Phase image Real image Imaginary image • Fieldmap = Field inhomogeneity map = TE : Echo time - Peak signal time

  6. Specific Problems Phase Unwrapping x = I Scanner Brain Segmentation II Fieldmap Correction

  7. Specific Problems Phase Unwrapping True phase Wrapped phase in original phase data Wrapped phase with noise Unwrapped phase: True phase Unwrapped phase: Fooled by noise

  8. Specific Problems Phase Unwrapping Problem. 1– Imperfect segmentation  Noise at boundary  Erroneous unwrapping by 1D conventional Unwrapping Solution! - Unwrapping from inside to outside: Seed growing Problem. 2– Islands  Erroneous unwrapping by slice by slice 2D based seed growing method Solution! – 3D volume based Unwrapping: 3D Seed growing

  9. Specific Problems Brain Segmentation Manual Method - time cost - requirement for sufficient training Automated Method - combination of image-processing techniques thresholding | clustering | region growing edge detection | morphological | surface modeling - Seeded region growing algorithm based method - Histogram - Morphology based method - Deformable surface modeling Problem – All the segmentation method is intensity dependent  May cause problem with phase map data Solution? – Segmentation usingphase map data

  10. Goal SimultaneousPhase unwrapping & Segmentation of brain area by assuming smoothly varying phase in brain for Fieldmap correction of fast MRI(EPI)

  11. Approach 3D seed growing unwrapping guided by noise-pole field. Based on papers by R. Cusack et.al. & Sofia et.al. • Generate pole field • Modify the pole field with initial thresholded mask Noise-pole field • Find purest point in the center of 3D brain data  Seed • Merge or unwrap adjacent pixels  Seed growing • Repeat with new, increased threshold  Iteration • Stop at the final threshold  Unwrapped phase map • Set nonzero brain area to ‘1’  Mask data (Segmentation) • Make fieldmap from two phase maps  Geometric correction of EPI

  12. Approach Details Generate: Noise-Pole field A’ A’ A A A  A’  Pole A = A’ Phase Map Pole Field Initial Mask Noise-Pole Field • Unique point! • Noise-pole field • Computationally expensive segmentation is unnecessary

  13. Approach Details Iterative seed growing:recursive algorithm • Implemented in Matlab • Easy to visualize/control image data • Poor to deal with recursive algorithm!  ‘Out of Memory!’ Problem • Converting to ‘C’ didn’t work • Repeating ‘for loops’ in a recursive function •  Increased speed and solved memory problem • ex) 20 repetition in a function reduced time 1/3 • Unwrapping from less noisy area to more noisy area

  14. Results.1 Phase Unwrapping

  15. Results.2 Brain Segmentation MRI intensity images Mask from new way Mask from High complexity segmentation (BET, Stephen M. Smith)

  16. Results.3 Undistortion

  17. Conclusion & Future Work • First work of brain segmentation using phase data • Phase only segmentation is possible research area • Reduce complexity of whole procedure of fieldmap generation •  Unwrapping and segmentation are executed at the same time • Has not applied to other applications • Smoothing and threshold parameters are to be chosen carefully • Narrow areas tends to be eroded by smoothing • Implementation in other language for faster operation