350 likes | 676 Views
MODULERA Modular UPS Systems 60 / 100 / 200kVA 3Phase in / 3Phase out . Main Features. Hot Swappable Modularized Parallel Architecture Decentralized parallel structure DSP ( Digital Signal Processor ) Controlled Technology Modular N+X Parallel Redundancy
E N D
MODULERA Modular UPS Systems 60 / 100 / 200kVA 3Phase in / 3Phase out
Main Features • Hot Swappable Modularized Parallel Architecture • Decentralized parallel structure • DSP ( Digital Signal Processor ) Controlled Technology • Modular N+X Parallel Redundancy • Parallel Operation up to 10 Power Modules • High Power Capacity up to 200kVA on per single Rack • Invest as You Grow , Easy to Upgrade • Common Battery Operation • Cold Start Function • Parallel connection availability of UPS Frames up to 4pcs
Main Features Low Input Current Distortion (THDi <3% )
Main Features High Input Power Factor ( p.f. = 0.99 )
Main Features High Efficiency ( up to 94% )
Main Features • High Output Power Factor ( p.f.= 0.9) • Wide input voltage 208V~478Vac • Wide input frequency range ( 40Hz – 70Hz ) • Plug & Play Type Hot Swappable Power Modules • Each Power module with individual LCD display • Touch-screen Graphical LCD Display Panel • Centralized module monitoring is also available • Smart Fan Speed Control • Fan spins according to load percentage ; • 50%: Spin slowly / over 50%: Spin at full Speed
Main Features • High MTBF ( 250.000 hours ) and Low MTTR • Battery Temperature Compensation • Powerful Charger Built in Module ( Max. 6Amp ) • Equip with Maintenance Bypass Switch for easy maintenance • RS232 & 485 Ports as standard communication • Remote EPO Function • Megatec/Mod Bus Protocol • Optional Communication Interfaces (SNMP or DRY contact)
MODULERA FRAME TYPES • MDL 3300-200K • MDL 3300-60K • MDL 3300-100K 60kVA & 100kVA 200kVA
MODULERA FRAME TYPES • MDL 3300-60K = 3+1 Modules ( 3modules for power upgrade + 1module for redundancy • MDL 3300-100K = 5Modules • MDL 3300-200K = 10Modules • Max. 4Frames can be connected in parallel
MODULERA POWER MODULE MDL3320-RM 3/3 Power Module • 20KVA/18KW Module Compact Size • Only 3U Height 3U Only
Plug-and-Play Hot Swappable Module • Safe Swappable Modular Concept • Reduce SPOF(Single Points of Failure) • Power Availability Increase • High Power Capacity • Reduced Footprint • Flexibility/Scalability • Less Service Cost • Lowest Installation Cost
Battery Temperature Compensation • Set from LCD Display • Compensate from 20 C: Reduce • 0.001V*6 of floating voltage per 1°C. • 0.002~0.006V * 6 per 1°C settable Battery Voltage Configurable • 384/408/432/456/480Vdc Configurable • Decrease Initial Investment • Increase Competition
Derating Operation • Derating as per Temperature : • Normal operation Temperature 0~40 C • Max. operation Temperature 50 C • De-rating operation: 10% per 5 C • Derating as per Altitude : • Max. Altitude for normal operation : 1500m • The load capacity should be reduced as shown in the below table when the UPS is installed in a place where altitude is higher than 1500 m;
Powerful Charger • Each Power Module: 6Amp • 60K: Max. 18A • 100K: Max. 30A • 200K: Max. 60A • Charging Current adjustable from LCD 3-Stage Intelligent Charging Modes • Constant Current • Constant Voltage • Floating (Boost Charge 2.30V to 2.35V per cell & Float Charge 2.20V to 2.29V per cell)
Power Module LCD Display • Input Voltage/Frequency • Output Voltage/Frequency • Load Capacity, Battery Voltage/Current • Charge Modes/Charger Status • Internal/Ambient Temperature • Module ID/Status • Alarm Codes
Touch-Screen Graphical LCD Display Panel • Complete status information about ; • Input / Output / Battery /Modules
Touch-Screen Graphical LCD Display Panel • UPS Management Commands; • Battery Test • Buzzer Set • Default Set Self-Test Date Mode: Weekly ▲ Week: SAT Time: 18:36 ▼ Lasting: 60min Ensure Cancel LBS Group Setting ▼Master▲ Ensure Cancel
Touch-Screen Graphical LCD Display Panel • Settings; • Language • System Parameters • Working Modes • Parallel ID • Battery Voltage/Capacity
Touch-Screen Graphical LCD Display Panel • Record All Events/Alarm Message; • Display Up to 49 events • 50 alarm messages ID:00 Record:0001 ▲ 2008-12-21 15:00:25 Status:On Line ▼ Event: On Line Alarm: CODE: CC00-0000 DF00-0000 0000 0000-0000 0000-0000 Quit
Touch-Screen Graphical LCD Display Panel • Charge Current Setting : Max Charge Current ▼ 25 ▲ Ensure Cancel
Touch-Screen Graphical LCD Display Panel • Battery Qty & Capacity Setting : Battery Number ▼ 20 ▲ Ensure Cancel Battery Group ▼ 1 ▲ Ensure Cancel
Multi-Communication Interfaces • 2 x RS485 Ports • 1 x RS232 Port • 1 x Mod Bus Port • 2 x Communication Slots
Communication Interface Options • SNMP Card • Megatec Protocol Supported
Communication Interface Options • Dry Contact Board
Mission critical & industrial applications • Operator Centres, Servers, Computer rooms, • Telecom Switchgear & Infrastructures, • Processing Control Equipments, • Security Systems, Emergency Lighting, FireProtection, • Airport Infrastructure, • Bank, Hospital, Healthcare Equipment …