200 likes | 352 Views
UM PPS Lab Activities. PPS meeting January 22, 2012 Claudio, Curtis, Dan, Riley. Panel Structure. Two lead glass ( % Pb ? ) substrate separated by glass beads mixed with the solder glass ( frit ) Dielectric posts and ribs could also affect the gap (Vishay Sr. Product Engineer statement)
E N D
UM PPS Lab Activities PPS meeting January 22, 2012 Claudio, Curtis, Dan, Riley
Panel Structure • Two lead glass (% Pb?) substrate separated by glass beads mixed with the solder glass (frit) • Dielectric posts and ribs could also affect the gap (Vishay Sr. Product Engineer statement) • Cathode strips covered by a layer of insulator (how thin/thick?) • Pixel cathode size & shape in CAD drawing topdie layer • Actual pixel slightly smaller due to dielectric slumping (Vishay Sr. Product Engineer statement) UM PPS Activities
Large Pitch Panels • Glass thickness ~ 0.088”mm = 2.23 mm • Gas gap Measured 0.195”-2·0.088” = 483μm (450-500 μm) • Long side (HV): 128 lines in 12.8” pixel pitch ~0.1”=2.5mm • Short side (RO): 32 lines in 3.2” pixel pitch ~0.1”=2.5mm • Gas Volume: 330.2mm x 88.9mm x 0.483mm = 14.18 cm3 13.5”=343 mm 3.5”=88.9 mm 3.2”=81.3 mm 13”=330.2 mm 4.0625”=103.2 mm 12.8125”=325.4 mm UM PPS Activities
Large Panels Cell Anode (RO) Pitch 0.1”=2.54 mm Electrode 0.5”~1.27 mm Space 0.5”~1.27 mm Cathode (HV) Pitch 0.1”=2.54 mm Electrode 0.55”~1.397 mm Space 0.45”~1.143 mm A(crossing):0.05” ˣ 0.055’=1.774 mm2 A(die): π·(0.05/2”)2=1.267 mm2 (~71) Packing factor =(Across+Adie)/2 * 1/Pitch2 ~23.5% 3 Vishay (VP1-3) + 2 Babcock (BP1-2) Ni-SnO2VP1 &VPC cracked 8 Vishay (VPA-E + F,G,H unused yet) Ni-Ni (VPD in Tel Aviv) UM PPS Activities
Mid-size Pitch Panel • Glass thickness Top & Bottom 0.088” = 2.23mm • Gas gap: Vishay document ~ 0.0116” = 294μm Measured 188” – 2·0.088” = 0.012” = 305 μm • 128 (HV) ˣ 40(RO) lines • Long 128 lines in 131/167 mm pitch: pixel~1mm connector=1.3mm • Short 64 lines in 65/81.5 mm pitch: pixel~1mm connector=1.3mm • Gas Volume: 160mm x 80mm x 0.3mm = 3.84 cm3 - - - - - - - - - - - - - - - - 175 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 169 mm - - - - - - - - - - - - - - - - - - - - - - - 70.0 mm - - - - - - - - 65.0 mm - - - - - - - - - - 86.6 mm - - - - - - - - - - - - - - - - - - 135 mm - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - 131 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 167 mm - - - - - - - - - - - - - - - - - - - UM PPS Activities
Mid-Size Panel Cell Anode (RO) Pitch 0.04” = 1.016 mm Electrode 0.0281”~0.714 mm Space 0.0119”~0.302 mm Cathode (HV) Pitch 0.04” = 1.016 mm Electrode 0.0174”~0.442 mm Space 0.0226”~0.574 mm A(crossing):0.0281” ˣ 0.0174”=0.315 mm2 A(die): (0.02”)2=0.258 mm2 (~82%) A(effective)=0.02” ˣ 0.0174”=0.224 mm2 (~71%) Packing factor =<Aeffective>/Pitch2~ 22% (not 64% as in Dan’s estimate intrinsic PDP efficiency higher) 6+6 Vishay (MPx) Ni-SnO2 + 1 old broken ( support) UM PPS Activities
Small Pitch Panel • Glass: Top(Anode)~0.063”=1.6mm Bottom~0.079”=2.0mm • Gas gap Vishay document ~ 0.007” = 178μm Measured 0.0150”-0.063”-0.079=0.008”=203μm • 160(HV) ˣ 40(RO) lines • Long 160 lines 10.6/9.8 mm pitch: pixel~0.6 connector=0.66mm • Short 40 lines 2.4/2.6 mm pitch: pixel~0.6 connector=0.65mm • Gas Volume: 10mm x 2.8mm x 0.2mm=5.6 mm3 10.7mm 10.0 mm 3.7 mm 2.8 mm 2.4 mm 2.6 mm 9.8 mm 10.6mm UM PPS Activities
Small Panel Cell Anode (RO) Pitch 0.024”=0.61 mm Electrode 0.008”~0.203 mm Space 0.016”~0.407 mm Cathode (HV) Pitch 0.024”=0.61 mm Electrode 0.014”~0.356 mm Space 0.010”~0.254 mm Die: Squares 0.014” ˣ 0.014” A(cross):0.008” ˣ 0.0016’=0.0826 mm2 A(effective):0.008” ˣ 0.0014’=0.0723 mm2 Packing factor=Aeffective/Pitch2 =19.4% 6+6 Vishay (SPx) Ni-SnO2 Black lines (between anodes): full length barrier ribs. How toll? UM PPS Activities
New Panel EMI Shield • Aluminum shield for PDP signal testing (HV) • 24” long ˣ 12” wide ˣ 16” high • Corners: 1.5” Al-extrusion + Copper tape (to be applied) • Top/Bottom: EMI Static Shield paper (holes for cables ...) UM PPS Activities
New Cabinet (Curtis & Riley) Top & sides covered by EMI Static Shield paper + aluminum base Optical base in place with motorized 2D micrometer Re-design and re-build the mid-size panel support 32.5”=82.5cm 32.5”=82.5cm 19”=48.3cm UM PPS Activities
Another MP1 Uniformity Run • Sudden end: the lab computer died for unknown reasons • Hit-map: higher response closer to the HV (smaller gap?) • Large variation: ± 50% (±20% on older runs, on used lines) • Similar shape for the 97 hourly hit-maps (inside errors): 1.7·106hit/20ch 87k hit/ch in 97h ~900 hit/ch·h → <Δ>~±3% UM PPS Activities
Uniformity Run in Time • In 97 hours the rate decreases by a factor ~2.5, with an initial jump in the first hour (new lines)! • Same behavior is found for every channel points to a single line property (SnO2 degradation) UM PPS Activities
Uniformity Channel Correction • Hit-map channel correction factor: important to verify the stability of these correction over the 97h of the run UM PPS Activities
Uniformity Channel Correction (2) • Correction spread estimate of the error on them: 2-8% (worse for channels with lower corrections) UM PPS Activities
1mm Position Scan Revisited Result ingredients: 1) Run Hit-map fit (5 parameters): N·exp[-(x-μ)2/2σ2] + (mx+q) 2) Line by line corrections from the fit peak amplitude 3) Re-fit the correctedhit-map 4) Means linear fit on central points 5) extra σ(mean)=150μm 3) Gaussian Breit-Wigner (5 par) N/[(x-μ)2+Γ2/4] + (mx+q) 0.979±0.002 (Full, no Δy) χ2=139.7/17 1.003±0.003 (11P, no Δy) χ2=10.83/11 0.981±0.007 (Full with Δy)χ2=11.84/17 1.005±0.011 (11P with Δy)χ2=0.974/11 UM PPS Activities
Line by Line Response UM PPS Activities
Corrected Hit Maps Fits Gaussian+Lin Breit-Wigner+Lin UM PPS Activities
Parameters Sigma Norm Mean Const Χ2/dof FWHM Slope UM PPS Activities
A Quick Calculation Theory: σ2data= σ2intrinsic+ σ2beam σbeam= 1.1 mm (GEANT) σBW ~ 1.4 mm (FWHM/2.35) • σintrinsic = 866 μm Best expectation ~300 μm • The width of the measured distribution could be larger because of: • Ionization starts inside the gas O(100 μm) larger beam spread • Systematic: misalignment slit-panel line, correction, fit function, ... • The simulation could underestimate the spread because of • Extra material after glass (dielectric and/or electrode) • Glass composition • Photon contribution (only betas simulated) UM PPS Activities
Conclusions • Positive impression on February 6 DoE lab tour (15’): very short introduction + two experiences and one animation • A lot of preparation work in the lab: • Panel geometry much more clear • New cabinet and EMI shield ready • Work on filling and testing our gas bottles • Wiener readout code now running in our dedicated lab laptop • The uniformity run on new lines shows a severe degradation of the rate as a function of time and a large channel by channel variation (total ± 50%), but quite stable in time • The position scan runs fitted with a Breit-Wigner (GEANT simulation best fit) seems to be better than Gaussian. To estimate the intrinsic resolution we need to understand the limitations of the simulation and the systematic errors involved in our data taking UM PPS Activities