1 / 18

ME 414 Design Project

ME 414 Design Project. Heat Exchanger Design. Created and Designed by: Michael Stark Joshua Keith Billy Burdette Brandon Mullen Joseph Listerman. Project Goals. Design Heat Exchanger Create a light weight heat exchanger Heat exchange must be as efficient as possible

Download Presentation

ME 414 Design Project

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME 414 Design Project Heat Exchanger Design Created and Designed by: Michael Stark Joshua Keith Billy Burdette Brandon Mullen Joseph Listerman

  2. Project Goals • Design Heat Exchanger • Create a light weight heat exchanger • Heat exchange must be as efficient as possible • Cost must be kept low as possible • The size of the heat exchanger must be under design constraint

  3. Project Guidelines • During the process of a liquid chemical product, its temperature needs to be reduced by 20 degrees Celsius. • Mass flow rate is 220,000 kg/hr • Fluid enters the heat exchanger at 45 C and should leave at 25 C • Material properties of this chemical product can be approximated as water • Cooling of the chemical product will be achieved by using treated city water • City water is available at 20 C • Mass flow rate is adjustable and one of the design parameters to be selected • Exit temperature of city water from the heat exchanger is a function of the selected mass flow rate Professor Toksoy

  4. Project Optimization • Must cool the chemical from 45 C to 25 C • Heat exchanger length can not exceed 7 meters • Heat exchanger shell diameter can not exceed 2 meters • Minimize heat exchanger shell and tube weight hence the cost • Minimize heat exchanger pressure drop Professor Toksoy

  5. Heat Exchanger Design Inputs for MATLAB • Chemical to be cooled was set as Shell side liquid • Mass flow rate of cooling water = 220 kg/sec • Shell ID = .889 m • Shell thickness = 5 mm • Tube OD = 6.35 mm • Tube thickness = .457 mm • Tube Length = 2.88 m • Baffle space = .6 m • Helical Baffles • Counter flow • One shell pass and one tube pass • Aluminum was used for both shell and tube materials • Gnielinski equation used for tube side Nusselt correlation • Square tube pitch

  6. Nusselt Correlation

  7. D.O.E. Run 1

  8. D.O.E. Run 2

  9. Final D.O.E.

  10. Factorial Design Analysis – Heat Rate • Tube length has the largest affect on the heat rate. • Shell ID has the smallest relative affect on heat rate. • Shell ID had a negative affect on heat rate. • This was a result of more tubes decreasing the velocity in the tube. • The result is laminar flow inside the tube.

  11. Factorial Design Analysis - ∆P Tube • We can see that tube length has the largest affect on tube side pressure drop. • Shell ID has no affect on tube pressure drop. • We expected tube OD to have a larger affect on tube side pressure drop.

  12. Factorial Design Analysis - ∆P Shell • Shell ID had the largest affect on shell side pressure drop. • The affect of tube OD on the pressure drop was surprising. • We attribute this affect to the 60° triangular pitch tube arrangement. • As tube OD grows larger there is more pressure drop in the shell.

  13. Factorial Design Analysis – HE Weight • The shell inside diameter has the largest affect on weight. • The larger the shell diameter the more tubes we could fit inside, thus increasing weight. • Because tube length determines the length of the heat exchanger, it too has a large affect on heat exchanger weight.

  14. Design Optimization - 1 • The design optimized to our original design. • We expected our final tube diameter to be 6.35 mm with a mass flow rate of 220 kg/s. • Optimal Tube OD was 8.3mm • The tube length was longer than our original design called for, which was a result of maximizing the q calculated. • We set target values for the shell and tube side pressure drops. • We set a target range for total weight between 900-1100 kg.

  15. Design Optimization - 2 • The design optimized to our original design. • We expected our final tube diameter to be 6.35 mm with a mass flow rate of 220 kg/s. • Optimal Tube OD was 8.3mm, adjusted it to 9.525 mm to coincide with standard tube dimensions. • The tube length was longer than our original design called for, which was a result of maximizing the q calculated. • We set target values for the shell and tube side pressure drops. • We set a target range for total weight between 900-1100 kg.

  16. Heat Exchanger Design Output from MATLAB

  17. Matlab Program Improvements • Create program checks in order to eliminate unrealistic designs. • If multiple tube passes are used with parallel flow it is possible to calculate a LMTD_CF that is an imaginary number. • Provide the operator more detailed information regarding the Nusselt correlations.

  18. Cost Summary • Heat Exchanger Dry Weight • 730 Kg • Heat Exchanger & Fluid Weight • 2287 Kg • Cost • OnlineMetals.com • $37.00 per 8ft length of aluminum tubing • Total estimated aluminum tubing cost $337,000.00 • $11.00 per 8ft length of mild steel tubing • Total estimated mild steel tubing cost $100,000.00 • Instillation and Manufacturing