80 likes | 351 Views
Instruction Manual. Programming Terminal. PT 2 00-G. Production No. Caution : for System Engineer ONLY. No.4 Tools. Panasonic Factory Solutions Co., Ltd. 2014/8/21. <Page> <Contents> 3 ・・・ 10-1 . PT200 Conversion tool(1)~(4). 10 . PT200SystemTools. 10_1 . PT200 Conversion tool(1).
E N D
Instruction Manual ProgrammingTerminal PT200-G Production No. Caution:for System Engineer ONLY No.4 Tools Panasonic Factory Solutions Co., Ltd. 2014/8/21
<Page> <Contents> 3・・・10-1. PT200 Conversion tool(1)~(4)
10.PT200SystemTools 10_1.PT200 Conversion tool(1) 1.ConvertStep(CM88/CM20F) PT200 PT200 Shift Tool LineConverter PT100 PT200 PT200 PT200 System Install (Tool→Convert Other Line) (PT200conversionTool) Data of PT100 is shifted to Virtual Line PT100_001 based on left Imformation. It is the preservation place of the undermentioned files that is maintained in the PT100 / PT100 to PT200.ini. ・PT100 Data PTBAK/PT100/DATA PT100/VData0001/ /Sort/Lib PT100/VData0001/PT100_001/Lib ・Sort/Lib PT100/PT100.CFG ・Registry (Export data of the Registry) nothing PartsData Registration Ini File is shifted to Actual Line. Special Nozzle is shifted to Actual Line. *PT100 Machine Data →It is shifted to Actual Line. (including PRU data) →It is shifted to Virtual Line. (including PRU data) (Virtual Name : PT100_001) *Ini File is shifted to Virtual Line. *Special Nozzle is shifted to Virtual Line. *ChipData →It is registered to Actual Line. →It is registered to Virtual Line. (Virtual Name : PT100_001) ChipData iniFile (Option setting files) Special Nozzle Machine Data Feeder fixed Nozzle fixed CM88/CM20
10.PT200SystemTools 10_1.PT200 Conversion tool(2) 2.ConvertStep (Modular Machine) PT200 Shift Tool LineConverter PT200 PT200 PT200 PT200 PT100 System Ins.Tool (Tool→Convert Other Line) (PT200conversionTool) Data of PT100 is shifted to Virtual Line PT100_001 based on left Imformation. It is the preservation place of the undermentioned files that is maintained in the PT100 / PT100 to PT200.ini. ・PT100 Data PTBAK/PT100/DATA PT100/VData0001/ /Sort/Lib PT100/VData0001/PT100_001/Lib ・Sort/Lib PT100/PT100.CFG ・Registry (Export data of the Registry) nothing PartsData Registration Data of Virtual Line →SomeMachines that is shifted to Actual Line as 1 Module. *Integration ChipData *Check on Common Data *Check on Skip Data *Check on Mount/ Block/BlockAttribute Data *PT100 Machine Data →It is shifted to Virtual Line as 1 Machine 1 Module. Module1 Module2 Module3 *Ini File is shifted to Virtual Line. *Special Nozzle →It is shifted to Actual Line. →It is shifted to Virtual Line. *ChipData →It is registered to Virtual Line. Modular Machine When the computer is restarted,ini File is shifted to Autual Line. Module1
10.PT200SystemTools 10_1.PT200 Conversion tool(3) 3. LineConverter Module統合時の contents of Check Board・・・ The result of the comparison of all models of the lot is displayed on substrate size of substrate data L,W,T and Offset coordinates X,Y. BDRecog・・・ The result of the comparison of all models of the lot is displayed on Board Recognition Data(Block Recognition) of Board Data and Badmark Recognition Data. BlkAttrib・・・ The result of the comparison of all models of the lot is displayed on Block Attribute Data(Block coordinates X,Y) Mount・・・ The interrelation of Mount Data,Block Attribute Data and Block Data is checked. 1. Is it correct that the Number of records? 2. Is it a numerical value which the Mount Data coordinates which contain the adjustment value was developed from the block data? Skip ・・・ Is there skip data in Mount Data and Stock Data, or not? When the shown numerical value which BoardData,BoardRecognitionData, BlockAttributeData is a disagreement between the each module, While convert the message for Confirmation is displayed. Select item you need and keep on convert. When A point of the substrate recognition and the Origin offset are the disagreements, It can be selected whether to correct coordinates. At that time, some notes are displayed. Read it and select item. Whether data skip can be selected. Select item after you confirms data.
【Assumable things when data shifts without correcting data. 】 Substrate size L,W,T There is a possibility of the transportation trouble. ※There is a possibility of the machine individual difference. Coordinate regerence Mounting is shifts without fail. Subtsrate recognition point/Origin offset There is a possibility Mounting gap. 1:The substrate data must be the same. 【Reason】 It is common in the modular editor. (The same data is used.) Substrate size L,W,T Coordinate reference Substrate recognition point Origin offset 2:BlockAttributeData(Number of Blocks/ Coordinates value) must be the same. 【Reason】 It is common in the modular editor. (The same data is used.) 【Assumable things when data is different.】 Mount Data reversely generates to Block Data. The block attribute becomes one. ※1 3:Relation between block data and mount data must be the same. 【Reason】 It is a specification which Mount Data reversely generates to Block Data. 【Assumable things when data is different. 】 Mount Data reversely generates to Block Data. The block attribute becomes one. ※1 【Assumable things when data is different. 】 becomes an error of the data check. The data correction is necessary. 4:the data check in the production data must be OK. 【Reason】 It makes an error of the data check after version up. 5:When the bat mark detection setting is turning onMeet the requirement of <above-mentioned> 2.3. 【Reason】 The bat mark coordinates are lost. (The block attribute becomes one.) Because It is a specification which Mount Data reversely generates to Block Data. 【Assumable things when data is different. 】 The bat mark cannot be normally detected. ※1 6:The Skip Data is deleted if it is not necessary because the Skip Data is released when data shifts. After data shifts, it is necessary to setting the Skip again. 【Reason】 It can’t import to the LineConverter if the data has skip setteing. 【Assumable things when data is different. 】 There is a possibility Mounting gap. 7:When data shifts (import) if either machine is passing setting ON the message about whether substrate recognition correctinh or not is displayed. But Don’t select correcting. 【Reason】 When you do not input the substrate recognition coordinates message Substrate recognition correction is displayed. 【Assumable things when correcting 】 There is a possibility Mounting gap. 8:It is necessary to setting Mounting point recognition, After the Version improves. 【Reason】 The data of Mounting point recognition can’t shift. ※1 Before the data shift, sorting are done the relation between Block Data and Mount Data becomes correct. And it will not do Mount Data reversely generates to Block Data. It can shift untouched data of BlockData,BlockAttributeData. 10.PT200SystemTools 10_1.PT200 Conversion tool(4) Notes : when The version improves from PT100 to PT200 between machines in module.