Centrifugal Pump for Neuroendoscopy

Centrifugal Pump for Neuroendoscopy. Client: Joshua E. Medow, MD, Department of Neurological Surgery Advisor: William L. Murphy, PhD Team: Jenna Spaeth, Team Leader Kellen Sheedy, Communicator Laura Piechura, BWIG Holly Liske, BSAC. Neuroendoscopy.

truman
Download Presentation

Centrifugal Pump for Neuroendoscopy

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Centrifugal Pump for Neuroendoscopy Client: Joshua E. Medow, MD, Department of Neurological Surgery Advisor: William L. Murphy, PhD Team: Jenna Spaeth, Team Leader Kellen Sheedy, Communicator Laura Piechura, BWIG Holly Liske, BSAC

  2. Neuroendoscopy Jenna: Could you please add references for the photos? Also, the picture on the right was pretty low resolution on the overhead – is there another one that could replace it? Otherwise, this slide looks pretty cool  During neurosurgery, an endoscope provides real-time imaging of the cranial surface and a port for introducing surgical instruments

  3. Problem Definition • A non-peristaltic flow of saline over the cranial surface clears debris for visualization of the surgical field • Flow is disrupted with the introduction of surgical instruments • 30-75% change in flow rate • Flooding and poor visibility

  4. Neuroendoscopy

  5. Client Requirements • Centrifugal pump modulates saline flow • Bio-Pump®, Bio-Console®, flow sensor

  6. Design Specifications • Develop electrical interface of neuroendoscope and Bio-Pump®: • Bio-Pump® flow rate: • Current = 5.00 L/min • Desired = 0.15 L/min • Negative feedback: • Control of saline flow rate with insertion of surgical instruments • Adjustable flow and equilibration rates • Optimal flow rate = 85-115 mL/min • Error ≤ 10 mL/min

  7. Differential Amplifier Design Inverting operational amplifiers Noninverting operational amplifier Differential amplifier

  8. VC Vdiff VS

  9. Differential Amplifier Design Advantages Disadvantages • Adjustable response through amplifier and potentiometer selection • Simplicity • Potential for negative voltage output from differential amplifier • Minimal adjustment of feedback rate

  10. Comparator Design Magnitude comparator Bipolar transistors Inverting operational amplifiers Noninverting operational amplifiers Summing amplifier

  11. Vs Vs<Vc Vs=Vc Vs>Vc V1 V2 VΣ V3

  12. Vs Vs<Vc Vs=Vc Vs>Vc V1 V2 VΣ V3

  13. Vs Vs<Vc Vs=Vc Vs>Vc V1 V2 VΣ V3

  14. Disadvantages Comparator Design Advantages Adjustable feedback rate Resilience to all comparisons of Vs and Vc Smooth equilibration • Relative complexity

  15. Design Matrix

  16. Preliminary Testing

  17. Future Work • Select components to optimize feedback • Purchase and assemble components • Integrate with existing equipment • Test and evaluate design • Monitor flow rate with introduction of surgical instruments • Develop customized control of Bio-Console®