1 / 25

Direct heating system ECOFLOOR Installation guide

Direct heating system ECOFLOOR Installation guide. DIRECT HEATING SYSTEM ECOFLOOR - FOR NEW BUILDING APPLICATIONS. heating mat or heating cable is placed into flexible cement (glue), on 5 cm concrete layer.

tynice
Download Presentation

Direct heating system ECOFLOOR Installation guide

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Direct heating system ECOFLOOR Installation guide

  2. DIRECT HEATING SYSTEM ECOFLOOR - FOR NEW BUILDING APPLICATIONS • heating mat or heating cable is placed into flexible cement (glue), on 5 cm concrete layer. • power density is used from 100 W/m2 (for habitable rooms with limited floor temperature) up to 160 W/m2(for bathrooms, laundries and no good heat-insulated floors) • very good and easy temperature control • floor heating is possible to combine with el.convectors or radiant panels

  3. DIRECT HEATING SYSTEM ECOFLOOR - FOR RECONSTRUCTION APPLICATIONS • modern floor heating with high level temperature controls • heating mat or heating cable is placed into thin layer of flexible cement (glue), on concrete layer or origin tiling. • power density is used according to type of room (100 W/m2 or 160 W/m2)

  4. ADVANTAGES OF DIRECT FLOOR HEATING • quick reaction to the changes in the user‘s heat requirements (warming of floor up to 20 min) • very good, accurate and easy temperature control • suitable for renovated floors with limited construction height

  5. ECOFLOOR INSTALLATION • at first choose the right floor heating application (storage, semi-storage or direct heating ) • calculate the heating loses, total heating output should be greater 10-20 % then calculated heating loss • According to type of room choose an appropriate heating density: - permanentaly occupied rooms up to 100 W/sqm - rooms occupied for short periods (bathrooms, -toilets) up to 160 W/sqm - laminated floors up to 80 W/sqm - wooden floors up to 60 W/sqm

  6. INSTALLATION NOTICES • minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm. • the heating cable may never be shortened or cutted !!! (only the cold connection lead)

  7. INSTALLATION NOTICES • Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm • the connector between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!) • the heating cable may never pass over an expansion joint

  8. EXPANSION WHY: the floor construction expands when temperature rises and must be furnished with expansion elements to prevent the floor construction being stressed ( tiling could be damaged, base layer cracked and peeled etc.) Expansion is necessary to provide: into place around the room‘s circumference, where floor heating will be used.( The whole floor construction must be a floating construction !) expansion is necessary to provide for rooms with area  25 m2 and for diagonal  7 m.

  9. Expansion joints • the choice of expansion joints depends on room‘s shape and structure - rooms with „L,Z,or T“ shapes should be divided into rectangular or squere sections • Expansion joint must not be discontinued and for cementation process is recomended flexible cement • ECOFLOOR heating cables and mats may never cross the expansion joints ! If the cold connections pass the expansion joints, they must lay freely within protective tubes

  10. Heating mat/cable ECOFLOOR laying to the flexible cement (glue) –new building 1. On the base(1)place thermal insulation (2)– expanded polystyrene at least or extruded polystyrene of min. thickness 5 cm 2. Place the steel reinforcement (3)to harden the concrete layer. Place the concrete layer 5 cm thick(4) 3. Penetrate the concrete layer. ECOFLOOR cables/mats (6) place into flexible cement (5). 4. Measure el parameters of heating system and lay the tiles. (7)

  11. Heating mat/cable ECOFLOOR laying to the flexible cement (glue) – floor reconstruction 1. Clean and penetrate the original tiling 2. Into flexible gluing cement place the ECOFLOOR heating cables/mats 3. Measure the parameters of heating cable/mat 4. Laying of new tiles

  12. Other possibility of ECOFLOOR laying Wooden floor construction

  13. Other possibility of ECOFLOOR laying Plasterboard floor construction

  14. Other possibility of ECOFLOOR laying Construction with self-levelling cement

  15. INSTALLATION OF ECOFLOOR HEATING CABLE CIRCUIT ADSL1PCOMFORTDIRECT FLOOR HEATING UNDER TILES ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“ 5. Fixation of el.conncector 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 1. Control measuring 6. Installation of Heating cable circuit 7. Control measuring 8. Thin layer flexible cementing (glueing) 9. New tiling

  16. INSTALLATION OF ECOFLOOR HEATING MAT LDTSCOMFORTDIRECT FLOOR HEATING UNDER TILES LDTS Heating mat (double conductor with 1 connection lead „cold tail“ 5. Heating mat laying 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 1. Control measuring 6. Mat sticking to the floor base by its self-adhesive tape 6. Heating mat installation 7. Control measuring 8. Thin layer flexible cementing (glueing) 9. New tiling

  17. FLOORING MATERIAL • The most suitable for ECOFLOOR systems:ceramic tile, marble, natural stone • Other suitable:Laminate floating and wooden parquet floors PVC without a rubber baseSpecial carpets without rubber base recommended by their manufacturers for use with floor heating • Unsuitable !!!:Carpets with pile more than 10 mm thick or with a rubber base PVC with a rubber

  18. Electrical installation • ECOFLOOR heating cable/mat has to be connected to the el.net just by a qualified person accordance with the manufacturer´s instructions • The total take-off (Amps) of heating mat/cable must never exceed the maximum value of thermostat switched current

  19. TEMPERATURE CONTROLS For floor heating are suitable following thermostats: Fenix Therm 100 Eco M/z1 Microline OCD 1999 H Fenix Therm 100 Eberle Instat 8

  20. Thermostat connection (thermostat with floor probe) L – phase (el.supply) N – neutral (el.supply) L’ –phase (Ecofloor) N’ – neutral (Ecofloor)

  21. Electrical installation directly throught the thermostat

  22. Electrical installation throught the el.box and contactor (1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)

  23. Direct heating ECOFLOOR Modern and comfort floor heating system