0 likes | 4 Views
Isolating specific cell populations from complex biological samples is a crucial step in many life science research applications. One innovative cell separation technology that has gained attention is the pluriSpin system, which utilizes the density gradient centrifugation principle to enable negative cell isolation. In this comprehensive guide, we'll walk you through the step-by-step process of using pluriSpin for negative cell isolation, highlighting the key features and benefits of this powerful cell separation technology.<br>visit us :- https://uberstrainer.com/
E N D
UBERSTRAINER • https://uberstrainer.com/
Step-by-Step Guide to Using pluriSpin for Negative Cell Isolation
Discover how pluriSpin helps in cell isolation, leveraging density gradient centrifugation to achieve high purity and viability of untouched cells, simplifying workflows for various biomedical applications. • Isolating specific cell populations from complex biological samples is a crucial step in many life science research applications. One innovative cell separationtechnology that has gained attention is the pluriSpin system, which utilizes the density gradient centrifugation principle to enable negative cell isolation. In this comprehensive guide, we'll walk you through the step-by-step process of using pluriSpin for negative cell isolation, highlighting the key features and benefits of this powerful cell separation technology.
Understanding Negative Cell Isolation with pluriSpin • The pluriSpin system is a novel negative cell separation technology that allows you to isolate viable, untouched cells directly from whole blood, buffy coat, or cord blood samples. Unlike traditional cell separation methods that rely on positive selection, the pluriSpin approach uses a unique immunodensity cell isolation reagent to label and remove unwanted cells, leaving your target cells unaffected. This gentle, one-step process minimizes the risk of activating or damaging the cells of interest, ensuring they remain functional and ready for downstream applications such as cell stimulation, cytotoxicity assays, cultivation, differentiation, and high-throughput screening.
Step-by-Step Guide to Using pluriSpin • Sample Preparation: Begin by resuspending the pluriSpin suspension, either by vortexing for 20 seconds or using a mixing device like the pluriPlix. • Cell Labeling: Add the pluriSpin suspension to your whole blood, buffy coat, or cord blood sample at a ratio of 20 μl per 1 ml of sample. Mix well by vortexing for 2 seconds. • Incubation: Incubate the sample-pluriSpin mixture for 15 minutes at room temperature, using a mixing device with tilting and 15 rpm rotation to ensure thorough labeling of unwanted cells. • Sample Dilution: Dilute the sample with an equal volume of wash buffer and mix gently.
5.Density Gradient Centrifugation: Layer the diluted sample over a density gradient medium and centrifuge for 15 minutes at 800 x g at room temperature with the brake off. • 6.Cell Collection: Carefully remove the enriched, untouched target cells from the density gradient medium-plasma interface and transfer them to a fresh tube. • 7. Cell Washing: Wash the collected cells by filling the reaction tube with wash buffer, centrifuging for 10 minutes at 300 x g (with no or small brake) at 4°C, and then aspirating the supernatant. Repeat this washing step once more. • 8. Final Resuspension: Reconstitute the cell pellet in your desired volume of wash buffer, and the purified, functional cells are now ready for your downstream applications.
Key Benefits of Using pluriSpin for Negative Cell Isolation • Gentle Cell Isolation: The pluriSpin system's negative isolation approach minimizes the risk of activating or damaging the cells of interest, ensuring they remain highly viable and functional. • One-Step Simplicity: The entire cell isolation process can be completed in a single step, using standard density gradient centrifugation equipment, without the need for specialized instruments or magnets. • Improved Cell Purity: By selectively removing unwanted cells, the pluriSpin system helps to increase the purity of your target cell population, enhancing the reliability and accuracy of your downstream analyses. • Versatility: The pluriSpin technology can be used to isolate a wide range of cell types, including those from whole blood, buffy coat, and cord blood samples, making it a versatile tool for various research applications.
Conclusion • The pluriSpin system's density gradient centrifugation principle offers a powerful and efficient solution for negative cell isolation, enabling researchers to obtain highly pure, functional cells with minimal manipulation. By following the step-by-step guide outlined in this blog, you can leverage the benefits of this innovative cell separation technology to advance your life science research and unlock new insights. For more information on the pluriSpin system and other cell enrichment techniques, visit the Pluriselect-USA website or contact our team of experts.
Thank you! https://uberstrainer.com/