Gage Repeatability & Reproducibility for Continuous Data

Gage Repeatability & Reproducibility for Continuous Data. Instructor’s Name. Introductions. Your Name Your Position What type of measurements you take in a given day. Agenda. Introduction…………………..…..……(30 minutes) Theory of gage R & R……..…..……..(50 minutes)

ulla-blair
Download Presentation

Gage Repeatability & Reproducibility for Continuous Data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gage Repeatability & Reproducibility forContinuous Data Instructor’s Name

  2. Introductions • Your Name • Your Position • What type of measurements you take in a given day

  3. Agenda • Introduction…………………..…..……(30 minutes) • Theory of gage R & R……..…..……..(50 minutes) • How to plan and execute a gage R & R study ...………………………………………..(20 minutes) --- Break --- • How to calculate the total gage R & R for a measurement system…………...……(75 minutes) --- Break --- • How to improve a gage R & R result ……………………………………...…..(60 minutes) --- Break --- • Conclusion & Wrap-Up………...….…(20 minutes)

  4. Theory of Gage Repeatability & Reproducibility

  5. What do we expect from data? • Accuracy • Calibration • Precision • Repeatability (Equipment) • Reproducibility (Operator) Accurate, but not precise Precise, but not accurate

  6. Accuracy AND Precision • A good measurement system must provide data that is BOTH accurate and precise. • How do we know? By conducting a GAGE REPEATABILITY AND REPRODUCIBILITY STUDY

  7. Measurement vs Measurement System • Measurement - value or data • Measurement System - everything involved in performing the measurement • measurement tool • part or sample • operator • procedure • environment Gage R & R takes into account the entire measurement system, not just the measurement.

  8. Measurement Resolution • The resolution of a gage is the smallest unit of measure the gage is able to read. • A gage should have a resolution of less than 10% of the total specification tolerance. • Example: Specification: +/- 0.050 • Q: What is the maximum gage resolution? • Total tolerance: 0.050 + 0.050 = 0.100 • 10% of total tolerance: 0.100 * 0.10 = 0.010 • A: The gage should have a resolution of 0.010 or less.

  9. Measurement Variation • Total Variation = Actual Part-to-Part Variation + Measurement Variation • Variation can come from anywhere within the measurement system: Man (operator) Method Material (part) Measurement Machine (tool) Mother Nature (environment)

  10. Exercise 1: Length of a Pen • Group Size: 3 - 4 participants • Materials: 6” plastic ruler, Exercise 1 in Student Manual • Task: Record all possible sources of measurement variation if your group was asked to measure the length of pen. • Duration: 10 minutes

  11. Total Gage R & R • The total gage R & R of a measurement system is the final number calculated from a gage R & R study. • Total gage R & R has two parts: • Repeatability or Equipment Variation (E.V.) • Reproducibility or Appraiser Variation (A.V.) Total Gage R & R = E.V.2 + A.V.2

  12. Judging the Total Gage R & R • If Total Gage R & R is: • < 20%: ACCEPTABLE • Between 20% and 30%: CONDITIONAL • > 30%: UNACCEPTABLE

  13. How to Plan and Execute a Gage R & R Study

  14. Planning • The typical gage R & R study uses • 2 or 3 operators • 10 parts • Each operator will measure each part two or three times. • In general, more data is better.

  15. Selecting Parts • Do NOT just select 10 parts at random! • Samples should cover the full range of the specification and beyond. • Example: Specification: 1.000 +/- 0.025 • Q: What should be the range of the samples? • Full specification range: 0.975 - 1.025 • A: The samples should cover the full specification range and beyond, so they should cover approximately 0.950 to 1.050. • Bonus Q: What should the gage resolution be for this case?

  16. Tips for Data Gathering • Stay as close to the existing process as possible. • Use a scribe to record data. • Identify samples. • Randomize the order of the samples for measurement. • Do not round the data.

  17. Time to take a… BREAK!

  18. How to Calculate a the Total Gage R & R for a Measurement System

  19. Tips on the Gage R & R Worksheet • Be able to perform all calculations by hand (a computer is not always available). • Save a master copy of the blank spreadsheet (Read-Only). • Shaded cells contain formulas. Enter data in white cells only. • Record all background information at the top of first page of the worksheet.

  20. Three Ways to Calculate • Measurement Unit Analysis • Raw calculation of the data. • Percent Tolerance Analysis • Relates measurement variation to the specification. • Product Acceptance • Percent Study Analysis • Relates measurement variation to the total process variation. • Process Control

  21. Special Cases • Discrete data (go/no go, count, categorical) • Checks for percent agreement among all operators. • Goal: 100% agreement • Destructive testing (torque, tensile strength) • Instead of repeated measurements, subgroups of sequentially processed parts are used. • Part variation within the subgroup should be minimized.

  22. Exercise 2: Dowel Stick Gage R & R • Group Size: 3 - 4 participants • Materials: Participant Kit, Student Manual • Task: Conduct a gage R & R on the measurement system for one dimension of the dowel stick. The dimension to be measured will be assigned by the instructor. • Duration: 45 minutes

  23. Time to take a… BREAK!

  24. How to Improve a Gage R & R Result

  25. Recall from earlier... • Repeatability - Equipment Variation • Reproducibility - Appraiser Variation • Tolerance Analysis - Product Acceptance • Study Analysis - Process Control

  26. Improving a System • High percent repeatability? • Operator judgment / opinion • Awkward sample • Gage calibration • Specification • High percent reproducibility? • Operator training • Sample state or position • Specification

  27. Exercise 3: Dowel Stick Gage R & R (2) • Group Size: 3 - 4 participants • Materials: Participant Kit, Student Manual • Task: Discuss how to improve the measurement system as it was used in Exercise 2. Confirm those improvements by performing a Gage R & R study on the new measurement system. • Duration: 55 minutes (10 for discussion, 45 for Gage R & R)

  28. Exercise 3: Dowel Stick Gage R & R (2) Percent Improvement = [(Exercise 2 Result) - (Exercise 3 Result)] (Exercise 2 Result)

  29. Time to take a… BREAK!

  30. Conclusion & Wrap-Up

  31. Review • The theory behind gage R & R studies • How to plan and execute a gage R & R study • How to calculate the total gage R & R • How to improve the result of a gage R & R study.

  32. Exam • There is an exam associated with this course! • Date: x Month yyyy • Duration: 90 minutes • Passing Score: 80%

  33. Evaluations • Anonymous • Please be candid! Thank you!!